메뉴 건너뛰기




Volumn 5, Issue 1, 1997, Pages 44-50

Comparison of ACL graft fixation pullout strengths

Author keywords

Anterior cruciate ligament; Anterior cruciate ligament anchor; Endobutton; Fixation; Interference screws; Pullout strength

Indexed keywords


EID: 0012621462     PISSN: 10628592     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (1)

References (37)
  • 1
    • 0025328902 scopus 로고
    • Accelerated rehabilitation after anterior cruciate ligament reconstruction
    • Shelbourne KD, Nitz P. Accelerated rehabilitation after anterior cruciate ligament reconstruction. Am J Sports Med 1990;18:292-9.
    • (1990) Am J Sports Med , vol.18 , pp. 292-299
    • Shelbourne, K.D.1    Nitz, P.2
  • 2
    • 0013189786 scopus 로고
    • Loss of motion following anterior cruciate ligament reconstruction
    • Jackson DW, Amoczky SP, Woo SLY, et al., eds. New York: Raven Press
    • Fu FH et al. Loss of motion following anterior cruciate ligament reconstruction. In: Jackson DW, Amoczky SP, Woo SLY, et al., eds. The anterior cruciate ligament: current and future concepts. New York: Raven Press, 1993:373-80.
    • (1993) The Anterior Cruciate Ligament: Current and Future Concepts , pp. 373-380
    • Fu, F.H.1
  • 3
    • 0025202383 scopus 로고
    • A complication of interference screw fixation in anterior cruciate ligament reconstruction
    • Doerr A et al. A complication of interference screw fixation in anterior cruciate ligament reconstruction. Orthop Rev 1990;19: 997-1000.
    • (1990) Orthop Rev , vol.19 , pp. 997-1000
    • Doerr, A.1
  • 4
    • 0024469123 scopus 로고
    • Pitfalls in the use of interference screws for anterior cruciate ligament reconstruction: Brief report
    • Matthews LS, Soffer SR. Pitfalls in the use of interference screws for anterior cruciate ligament reconstruction: brief report. Arthroscopy 1989;5:225-6.
    • (1989) Arthroscopy , vol.5 , pp. 225-226
    • Matthews, L.S.1    Soffer, S.R.2
  • 5
    • 0021337787 scopus 로고
    • Biomechanical analysis of human ligament grafts used in knee-ligament repairs and reconstructions
    • Noyes FR et al. Biomechanical analysis of human ligament grafts used in knee-ligament repairs and reconstructions. J Bone Joint Surg [Am] 1984;66:344-52.
    • (1984) J Bone Joint Surg [Am] , vol.66 , pp. 344-352
    • Noyes, F.R.1
  • 6
    • 0026832884 scopus 로고
    • Effect of tension and placement of a prosthetic ACL on the arthroposterior laxity of the knee
    • Fleming B et al. Effect of tension and placement of a prosthetic ACL on the arthroposterior laxity of the knee. J Orthop Res 1992; 10:177-86.
    • (1992) J Orthop Res , vol.10 , pp. 177-186
    • Fleming, B.1
  • 7
    • 0027529850 scopus 로고
    • Isometric versus tension measurements. A comparison for the reconstruction of the ACL
    • Fleming B et al. Isometric versus tension measurements. A comparison for the reconstruction of the ACL. Am J Sports Med 1993; 21:82-8.
    • (1993) Am J Sports Med , vol.21 , pp. 82-88
    • Fleming, B.1
  • 8
    • 3643112676 scopus 로고
    • Evaluation of interference fit fixation at low torques of screw insertion
    • San Francisco, CA
    • Black K. Evaluation of interference fit fixation at low torques of screw insertion. Presented at AAOS Annual Meeting, San Francisco, CA, 1993.
    • (1993) AAOS Annual Meeting
    • Black, K.1
  • 9
    • 0027508563 scopus 로고
    • The biomechanics of interference screw fixation of patellar tendon anterior cruciate ligament grafts
    • Brown CH. The biomechanics of interference screw fixation of patellar tendon anterior cruciate ligament grafts. Am J Sports Med 1993;21:880-6.
    • (1993) Am J Sports Med , vol.21 , pp. 880-886
    • Brown, C.H.1
  • 10
    • 0023473023 scopus 로고
    • Evaluation of fixation methods in cruciate ligament replacement
    • Butler DL. Evaluation of fixation methods in cruciate ligament replacement. Instr Course Lect 1987;36:173-8.
    • (1987) Instr Course Lect , vol.36 , pp. 173-178
    • Butler, D.L.1
  • 11
    • 0028017502 scopus 로고
    • Optimal graft fixation - The effect of gap size on bone plug fixation in ACL reconstructions
    • Butler JC et al. Optimal graft fixation - the effect of gap size on bone plug fixation in ACL reconstructions. Arthroscopy 1994;10: 524-9.
    • (1994) Arthroscopy , vol.10 , pp. 524-529
    • Butler, J.C.1
  • 12
    • 3643122017 scopus 로고
    • A comparison of patellar tendon graft fixation techniques in ACL reconstruction using a goat model
    • Orlando, FL
    • Castello PH et al. A comparison of patellar tendon graft fixation techniques in ACL reconstruction using a goat model. Presented at AAOS Annual Meeting, Orlando, FL, 1995.
    • (1995) AAOS Annual Meeting
    • Castello, P.H.1
  • 13
    • 0023280269 scopus 로고
    • A biomechanical comparison of different surgical techniques of graft fixation in anterior cruciate ligament reconstruction
    • Kurosaka M, Yoshiya S, Andrish JT. A biomechanical comparison of different surgical techniques of graft fixation in anterior cruciate ligament reconstruction. Am J Sports Med 1987;15:225-9.
    • (1987) Am J Sports Med , vol.15 , pp. 225-229
    • Kurosaka, M.1    Yoshiya, S.2    Andrish, J.T.3
  • 14
    • 0027479133 scopus 로고
    • Fixation strengths of patellar tendon-bone grafts
    • Matthews LS et al. Fixation strengths of patellar tendon-bone grafts. Arthroscopy 1993;9:76-81.
    • (1993) Arthroscopy , vol.9 , pp. 76-81
    • Matthews, L.S.1
  • 15
    • 0011415994 scopus 로고
    • Graft selection, placement, fixation, and tensioning for anterior cruciate ligament reconstruction
    • Rubinstein RA, Shelbourne KD. Graft selection, placement, fixation, and tensioning for anterior cruciate ligament reconstruction. Oper Tech Sports Med 1993;1:10-5.
    • (1993) Oper Tech Sports Med , vol.1 , pp. 10-15
    • Rubinstein, R.A.1    Shelbourne, K.D.2
  • 16
    • 3643112677 scopus 로고    scopus 로고
    • Fixation in anterior cruciate ligament reconstructions. Instructional course lecture 410, anterior cruciate ligament reconstruction: Primary and revision
    • Atlanta, GA
    • Stapleton TR. Fixation in anterior cruciate ligament reconstructions. Instructional course lecture 410, anterior cruciate ligament reconstruction: primary and revision. AAOS Annual Meeting, Atlanta, GA, 1996.
    • (1996) AAOS Annual Meeting
    • Stapleton, T.R.1
  • 17
    • 3643071982 scopus 로고
    • ACL reconstructions using interference screws, Acufex endobutton, and Mitek ACL anchors: A biomechanical analysis
    • Columbus, GA
    • Stapleton TR, Waldrop JI, et al. ACL reconstructions using interference screws, Acufex endobutton, and Mitek ACL anchors: a biomechanical analysis. Presented at Hughston Society Annual Meeting, Columbus, GA, 1995.
    • (1995) Hughston Society Annual Meeting
    • Stapleton, T.R.1    Waldrop, J.I.2
  • 18
    • 3643140871 scopus 로고    scopus 로고
    • Endoscopic ACL reconstruction utilizing a quadrupled hamstring tendon autograft with direct RCI interference screw fixation
    • Smith & Nephew Donjoy, Columbus, GA, February
    • Pinczewski L. Endoscopic ACL reconstruction utilizing a quadrupled hamstring tendon autograft with direct RCI interference screw fixation. Presented at Lecture/Laboratory Session of RCI Screw, Smith & Nephew Donjoy, Columbus, GA, February 1996.
    • (1996) Lecture/Laboratory Session of RCI Screw
    • Pinczewski, L.1
  • 19
    • 0022557341 scopus 로고
    • Soft tissue fixation to bone
    • Robertson DB et al. Soft tissue fixation to bone. Am J Sports Med 1986;14:398-103.
    • (1986) Am J Sports Med , vol.14 , pp. 398-1103
    • Robertson, D.B.1
  • 20
    • 3643093860 scopus 로고
    • Failure strength of patellar tendon, quadriceps tendon and hamstring tendon grafts in ACL reconstructions: A biomechanical and histologic analysis
    • Vail, CO
    • Stapleton TR, Curd DT, Baker CL. Failure strength of patellar tendon, quadriceps tendon and hamstring tendon grafts in ACL reconstructions: a biomechanical and histologic analysis. Presented at Society of Military Orthopaedic Surgeons Annual Meeting, Vail, CO, 1995.
    • (1995) Society of Military Orthopaedic Surgeons Annual Meeting
    • Stapleton, T.R.1    Curd, D.T.2    Baker, C.L.3
  • 22
    • 0029063410 scopus 로고
    • An alternative to cruciate reconstruction graft: The central quadriceps tendon
    • Fulkerson JP, Langeland R. An alternative to cruciate reconstruction graft: the central quadriceps tendon. Arthroscopy 1995;11:252-4.
    • (1995) Arthroscopy , vol.11 , pp. 252-254
    • Fulkerson, J.P.1    Langeland, R.2
  • 23
    • 3643060506 scopus 로고
    • Mechanical performance of endoscopic anterior cruciate ligament fixation techniques: A comparison of metal devices and in-situ setting injectable hydroxyapatite
    • Toronto, ON
    • Liu SH et al. Mechanical performance of endoscopic anterior cruciate ligament fixation techniques: a comparison of metal devices and in-situ setting injectable hydroxyapatite. Presented at AASM Annual Meeting, Toronto, ON, 1995.
    • (1995) AASM Annual Meeting
    • Liu, S.H.1
  • 24
    • 33645317987 scopus 로고
    • Tendon healing in a bone tunnel: A biomechanical and histological study in the dog
    • Rodeo SA et al. Tendon healing in a bone tunnel: a biomechanical and histological study in the dog. J Bone Joint Surg [Am] 1993;75A.
    • (1993) J Bone Joint Surg [Am]
    • Rodeo, S.A.1
  • 25
    • 3643078325 scopus 로고    scopus 로고
    • Complications in anterior cruciate ligament surgery using autogenous patellar tendon graft
    • Washington, DC, April
    • Stapleton TR, Terry GC, et al. Complications in anterior cruciate ligament surgery using autogenous patellar tendon graft. Presented at AANA Annual Meeting, Washington, DC, April 1996.
    • (1996) AANA Annual Meeting
    • Stapleton, T.R.1    Terry, G.C.2
  • 26
    • 0023280269 scopus 로고
    • A biomechanical comparison of different surgical techniques of graft fixation in anterior cruciate ligament reconstruction
    • Kurosaka M, Yoshiya S, Andrish JT. A biomechanical comparison of different surgical techniques of graft fixation in anterior cruciate ligament reconstruction. Am J Sports Med 1987;15:225-9.
    • (1987) Am J Sports Med , vol.15 , pp. 225-229
    • Kurosaka, M.1    Yoshiya, S.2    Andrish, J.T.3
  • 27
    • 3643147044 scopus 로고
    • Basic science of ACL reconstructions. Instructional course lecture 240, anterior cruciate ligament: Surgical principles and techniques
    • Arnoczky SP. Basic science of ACL reconstructions. Instructional course lecture 240, anterior cruciate ligament: surgical principles and techniques. Presented at AAOS Annual Meeting, 1994.
    • (1994) AAOS Annual Meeting
    • Arnoczky, S.P.1
  • 28
    • 0000707850 scopus 로고
    • Optimizing interference fixation for cruciate ligament reconstruction
    • Resnick AM. Optimizing interference fixation for cruciate ligament reconstruction. Trans Orthop Res Soc 1990;15:519.
    • (1990) Trans Orthop Res Soc , vol.15 , pp. 519
    • Resnick, A.M.1
  • 29
    • 0029198272 scopus 로고
    • Anterior cruciate ligament reconstruction: Why do failures occur?
    • Johnson DL, Fu FH. Anterior cruciate ligament reconstruction: why do failures occur? Instr Course Lect 1995;44:391-406.
    • (1995) Instr Course Lect , vol.44 , pp. 391-406
    • Johnson, D.L.1    Fu, F.H.2
  • 30
    • 3643070922 scopus 로고
    • Endoscopic one incision vs two incision ACL reconstructions: A biomechanical analysis
    • Orlando, FL
    • Stapleton TR, Waldrop JI, et al. Endoscopic one incision vs two incision ACL reconstructions: a biomechanical analysis. Presented at 5th Annual SEC Sports Medicine Symposium, Orlando, FL, 1995.
    • (1995) 5th Annual SEC Sports Medicine Symposium
    • Stapleton, T.R.1    Waldrop, J.I.2
  • 31
    • 0020656022 scopus 로고
    • Vascularized patellar tendon graft with rigid internal fixation for ACL insufficiency
    • Lambert KL. Vascularized patellar tendon graft with rigid internal fixation for ACL insufficiency. Clin Orthop 1983;172:85-9.
    • (1983) Clin Orthop , vol.172 , pp. 85-89
    • Lambert, K.L.1
  • 32
    • 3643146024 scopus 로고
    • Effects of interference screw length on tibial tunnel fixation for anterior cruciate reconstruction
    • Orlando, FL, December
    • Stube KC. Effects of interference screw length on tibial tunnel fixation for anterior cruciate reconstruction. Presented at AAOS Annual Meeting, Orlando, FL, December, 1995.
    • (1995) AAOS Annual Meeting
    • Stube, K.C.1
  • 33
    • 0028917810 scopus 로고
    • Assessment of initial fixation of endoscopic interference femoral screws with divergence and parallel placement
    • Lemos MJ et al. Assessment of initial fixation of endoscopic interference femoral screws with divergence and parallel placement. Arthroscopy 1995;11:37-41.
    • (1995) Arthroscopy , vol.11 , pp. 37-41
    • Lemos, M.J.1
  • 34
  • 35
    • 34748843898 scopus 로고
    • Technique for endoscopic methd of ACL reconstruction
    • Mansfield, MA: Acufex Microsurgical, Inc.
    • Rosenberg TD. Technique for endoscopic methd of ACL reconstruction. Technical Bulletin. Mansfield, MA: Acufex Microsurgical, Inc., 1989.
    • (1989) Technical Bulletin
    • Rosenberg, T.D.1
  • 36
    • 3643113751 scopus 로고
    • Comparison of failure strength between metallic and bioabsorbable interference screws
    • Toronto, Canada
    • Brown GA et al. Comparison of failure strength between metallic and bioabsorbable interference screws. Presented at American Academy of Sports Medicine Annual Meeting, Toronto, Canada, 1995.
    • (1995) American Academy of Sports Medicine Annual Meeting
    • Brown, G.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.