메뉴 건너뛰기




Volumn 456, Issue , 1998, Pages 329-337

A similitude model for testing greenhouse evaporative cooling pads under the hot-arid conditions of the U.A.E.

Author keywords

Date fronds; Evaporative cooling; Protected cropping; Similitude model

Indexed keywords


EID: 0012395553     PISSN: 05677572     EISSN: None     Source Type: Book Series    
DOI: 10.17660/actahortic.1998.456.39     Document Type: Conference Paper
Times cited : (7)

References (17)
  • 1
    • 84879490815 scopus 로고
    • Utilization of date palm leaves and fibers as wetted pads in evaporative coolers
    • Abdallah K., Abdallah A. and Hashim H., 1995. Utilization of date palm leaves and fibers as wetted pads in evaporative coolers. AMA 26 (2) 52-54.
    • (1995) AMA , vol.26 , Issue.2 , pp. 52-54
    • Abdallah, K.1    Abdallah, A.2    Hashim, H.3
  • 2
    • 0025496559 scopus 로고
    • Utilization of wind power and wetted pads to evaporatively cool cow sheds under hot and arid climatic conditions
    • Abdallah A. and Narendran R., 1990. Utilization of wind power and wetted pads to evaporatively cool cow sheds under hot and arid climatic conditions. AMA 21(4):33-37.
    • (1990) AMA , vol.21 , Issue.4 , pp. 33-37
    • Abdallah, A.1    Narendran, R.2
  • 4
    • 84879482878 scopus 로고
    • Parameters affecting water consumption for greenhouse cooling in hot arid region
    • Ayyash S. and Rasas M., 1990. Parameters affecting water consumption for greenhouse cooling in hot arid region. J. of Arab Gulf Sc. Res. 8(1):51-63
    • (1990) J. of Arab Gulf Sc. Res. , vol.8 , Issue.1 , pp. 51-63
    • Ayyash, S.1    Rasas, M.2
  • 5
    • 84879480493 scopus 로고
    • Improving evaporative cooling effectiveness by reducing ventilation rate
    • St. Joseph, Michigan - USA
    • Bottcher R., Kesler D. and Baughman R., 1988. Improving evaporative cooling effectiveness by reducing ventilation rate. American Soc. of Agr. Eng. Paper No. 88-4069. St. Joseph, Michigan - USA. pp 27.
    • (1988) American Soc. of Agr. Eng. Paper No. 88-4069 , pp. 27
    • Bottcher, R.1    Kesler, D.2    Baughman, R.3
  • 6
    • 0024619778 scopus 로고
    • Evaporative cooling using a pneumatic misting system
    • Bottcher R., Baughman R. and Kesler D., 1989. Evaporative cooling using a pneumatic misting system. Trans. ASAE 32(2):671-676.
    • (1989) Trans. ASAE , vol.32 , Issue.2 , pp. 671-676
    • Bottcher, R.1    Baughman, R.2    Kesler, D.3
  • 8
    • 0022942508 scopus 로고
    • Experimental determination of heat and mass transfer coefficients in aspen pads
    • Dowdy J., Reid R. and Handy T., 1986. Experimental determination of heat and mass transfer coefficients in aspen pads. ASHRAE Trans. 92 (2 a) 60-70.
    • (1986) ASHRAE Trans. , vol.92 , Issue.2 A , pp. 60-70
    • Dowdy, J.1    Reid, R.2    Handy, T.3
  • 9
    • 0000454932 scopus 로고
    • Experimental determination of heat and mass transfer coefficients in rigid impregnated cellulose evaporative media
    • Dowdy J and Karabash N., 1987. Experimental determination of heat and mass transfer coefficients in rigid impregnated cellulose evaporative media. ASHRAE Trans. 93 (2) 382-395.
    • (1987) ASHRAE Trans. , vol.93 , Issue.2 , pp. 382-395
    • Dowdy, J.1    Karabash, N.2
  • 10
    • 0025798095 scopus 로고
    • Numerical optimization of evaporative misting systems
    • Gates R., Timmons M. and Bottcher R., 1991. Numerical optimization of evaporative misting systems. Trans. ASAE 34 (1) 275-280.
    • (1991) Trans. ASAE , vol.34 , Issue.1 , pp. 275-280
    • Gates, R.1    Timmons, M.2    Bottcher, R.3
  • 11
    • 0026225899 scopus 로고
    • Facility for testing exhaust ventilation fans
    • Heber A., Cole S. and Murphy J., 1991. Facility for testing exhaust ventilation fans. Appl. Eng. in Agric. 7(5):599-605.
    • (1991) Appl. Eng. in Agric. , vol.7 , Issue.5 , pp. 599-605
    • Heber, A.1    Cole, S.2    Murphy, J.3
  • 12
    • 0026186043 scopus 로고
    • Evaporative cooling pads: Test procedures and evaluation
    • Koca R., Hughes W. and Christianson L., 1991. Evaporative cooling pads: test procedures and evaluation. Appl. Eng. in Agr. 7(4):485-490.
    • (1991) Appl. Eng. in Agr. , vol.7 , Issue.4 , pp. 485-490
    • Koca, R.1    Hughes, W.2    Christianson, L.3
  • 13
    • 0020223308 scopus 로고
    • Heat transfer in evaporative cooling pad
    • St. Joseph - Michigan, USA
    • Mannix J., Koon J. and Flood C. 1982. Heat transfer in evaporative cooling pad. ASAE paper no. 82-4062, St. Joseph - Michigan, USA.
    • (1982) ASAE Paper No. 82-4062
    • Mannix, J.1    Koon, J.2    Flood, C.3
  • 14
    • 84879485491 scopus 로고
    • Ministry of Agriculture and Fisheries - MAF., United Arab Emirates
    • Ministry of Agriculture and Fisheries - MAF., 1994. Agricultural Statistics Book. United Arab Emirates.
    • (1994) Agricultural Statistics Book
  • 15
    • 0030188898 scopus 로고    scopus 로고
    • Evaporative cooling performance resulting from changes in water temperature
    • Simmons J. and Lott B., 1996. Evaporative cooling performance resulting from changes in water temperature. Appl. Eng. in Agric. 12(4):497-500.
    • (1996) Appl. Eng. in Agric. , vol.12 , Issue.4 , pp. 497-500
    • Simmons, J.1    Lott, B.2
  • 17
    • 0020927102 scopus 로고
    • Evaporative cooling
    • Mylo, A. & N. John, eds. American Society of Agricultural Engineers Pub, USA
    • Wiersma F. and Short T., 1983. Evaporative cooling. in: Ventilation of Agricultural Structures - Mylo, A. & N. John, eds. American Society of Agricultural Engineers Pub. pp 101-118. USA.
    • (1983) Ventilation of Agricultural Structures , pp. 101-118
    • Wiersma, F.1    Short, T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.