1
-
-
0012056333
-
-
Environmental Monitoring Systems Laboratory Office of Research and Development, Las Vegas, Nevada, EPA/600-R-93/073, March
-
US Environmental Protection Agency An X-ray fluorescence survey of lead contaminated residential soils in Leadville, Colorado: a case study, Environmental Monitoring Systems Laboratory Office of Research and Development, Las Vegas, Nevada, EPA/600-R-93/073, March 1993.
-
(1993)
An X-ray Fluorescence Survey of Lead Contaminated Residential Soils in Leadville, Colorado: A Case Study
-
-
-
2
-
-
9144243979
-
X-ray fluorescence field method for screening of inorganic contaminants at hazardous waste sites
-
M.S. Simmons (Ed.), Ch. 9, Lewis Publishers, Chelsea, Michigan
-
G.A. Raab, R.E. Enwall, W.H. Cole III, M.L. Faber, L.A. Eccles, X-ray fluorescence field method for screening of inorganic contaminants at hazardous waste sites, in: M.S. Simmons (Ed.), Hazardous Waste Measurements, Ch. 9, Lewis Publishers, Chelsea, Michigan, 1991.
-
(1991)
Hazardous Waste Measurements
-
-
Raab, G.A.1
Enwall, R.E.2
Cole III, W.H.3
Faber, M.L.4
Eccles, L.A.5
-
3
-
-
9144229849
-
Technology assessment of field portable instrumentation for use at Rocky Mountain Arsenal: Final report
-
abstract 49176, ORNL/TM-1052, DE88015357
-
R.A. Jenkins, M.P. Maskarinec, W.H. Griest, F.F. Dyer, R.L. Moody, M.V. Buchanan, Technology assessment of field portable instrumentation for use at Rocky Mountain Arsenal: final report, Energy Res. Abstract 13 (21) abstract 49176, ORNL/TM-1052, DE88015357, 1988.
-
(1988)
Energy Res. Abstract
, vol.13
, Issue.21
-
-
Jenkins, R.A.1
Maskarinec, M.P.2
Griest, W.H.3
Dyer, F.F.4
Moody, R.L.5
Buchanan, M.V.6
-
5
-
-
9144263358
-
SCAPS X-ray fluorescence sensor for detection of heavy metal concentrations in soil using a continuous push simulation
-
in preparation
-
C.W. Unsell, B.J. McDonald, W.T. Elam, SCAPS X-ray fluorescence sensor for detection of heavy metal concentrations in soil using a continuous push simulation, Nucl. Instr. and Meth. A (1998), in preparation.
-
(1998)
Nucl. Instr. and Meth. A
-
-
Unsell, C.W.1
McDonald, B.J.2
Elam, W.T.3
-
6
-
-
0012194643
-
Standard soil sample preparation error and comparison of portable XRF to laboratory AA analytical results
-
R.J. VanCott, B.J. McDonald, A.G. Seelos, Standard soil sample preparation error and comparison of portable XRF to laboratory AA analytical results, Nucl. Instr. and Meth. A 422 (1998) 801.
-
(1998)
Nucl. Instr. and Meth. A
, vol.422
, pp. 801
-
-
VanCott, R.J.1
McDonald, B.J.2
Seelos, A.G.3
-
7
-
-
6244301866
-
-
Ph.D. Dissertation, Civil Engineering, University of Utah, Salt Lake City, Utah
-
B.J. McDonald, McDonald-Trautner interval development with application to the calibration of a portable X-ray fluorescence spectrometer, Ph.D. Dissertation, Civil Engineering, University of Utah, Salt Lake City, Utah, 1996.
-
(1996)
McDonald-Trautner Interval Development with Application to the Calibration of a Portable X-ray Fluorescence Spectrometer
-
-
McDonald, B.J.1
|