메뉴 건너뛰기




Volumn 1939, Issue , 1993, Pages 82-91

Far-IR spectral response measurements of the Clouds and the Earth's Radiant Energy System (CERES) sensors using a Fourier transform spectrometer and pyro-electric reference detector

Author keywords

[No Author keywords available]

Indexed keywords

BUDGET CONTROL; FOURIER TRANSFORM INFRARED SPECTROSCOPY; SPACECRAFT INSTRUMENTS; SPECTROMETERS;

EID: 0010388468     PISSN: 0277786X     EISSN: 1996756X     Source Type: Conference Proceeding    
DOI: 10.1117/12.152859     Document Type: Conference Paper
Times cited : (9)

References (10)
  • 1
    • 84995106677 scopus 로고
    • The earth radiation budget experiment: Science and implementation
    • May
    • B. R. Barkstrom and G. L. Smith, "The Earth Radiation Budget Experiment: Science and Implementation", Reviews of Geophysics, No. 2, vol. 24, pp. 379-390, May 1986.
    • (1986) Reviews of Geophysics , vol.24 , Issue.2 , pp. 379-390
    • Barkstrom, B.R.1    Smith, G.L.2
  • 2
    • 84995036148 scopus 로고
    • Earth radiation budget experiment scanner instrument
    • May
    • L. P. Kopia, "Earth Radiation Budget Experiment Scanner Instrument", Reviews of Geophysics, vol. 24, No. 2, pp 400-406, May 1986.
    • (1986) Reviews of Geophysics , vol.24 , Issue.2 , pp. 400-406
    • Kopia, L.P.1
  • 3
    • 0024946420 scopus 로고
    • Characterizations of the earth radiation budget experiment scanning radiometers
    • R. B. Lee III, B. R. Barkstrom, N. Halyo, M. A. Gibson, and L. M. Avis, "Characterizations of the Earth Radiation Budget Experiment scanning radiometers", SPIE Proc, vol. 1109, pp. 186-194, 1989.
    • (1989) SPIE Proc , vol.1109 , pp. 186-194
    • Lee, R.B.1    Barkstrom, B.R.2    Halyo, N.3    Gibson, M.A.4    Avis, L.M.5
  • 5
    • 0026263692 scopus 로고
    • Radiometric calibration plan for the clouds and the earth's radiant energy system (CERES) scanning instruments
    • April
    • P. J. Jarecke, M. A. Folkman, L. A. Darnton, "Radiometric Calibration Plan for the Clouds and the Earth's Radiant Energy System (CERES) Scanning Instruments", SPIEProc, vol. 1493, pp. 244-254, April 1991.
    • (1991) SPIEProc , vol.1493 , pp. 244-254
    • Jarecke, P.J.1    Folkman, M.A.2    Darnton, L.A.3
  • 6
    • 0026284911 scopus 로고
    • Enhancements to the radiometric calibration facility for the clouds and the earth's radiant energy system (CERES) instruments
    • April
    • Folkman, P. J. Jarecke, and L. A. Darnton, "Enhancements to the Radiometric Calibration Facility for the Clouds and the Earth's Radiant Energy System (CERES) Instruments", SPIE Proc, vol. 1493, pp. 255-266, April 1991.
    • (1991) SPIE Proc , vol.1493 , pp. 255-266
    • Folkman, P.J.J.1    Darnton, L.A.2
  • 7
    • 0005357949 scopus 로고
    • Clouds and the earth's radiant energy system (CERES) longwave calibration plan and radiometric test model (RTM) calibration results
    • in press
    • P. J. Jarecke, M. A. Folkman, T. R. Hedman, and M. E. Frink, "Clouds and the Earth's Radiant Energy System (CERES) Longwave Calibration Plan and Radiometric Test Model (RTM) Calibration Results", Metrologia (in press), Vol. 30, 1993.
    • (1993) Metrologia , vol.30
    • Jarecke, P.J.1    Folkman, M.A.2    Hedman, T.R.3    Frink, M.E.4
  • 9
    • 0002468304 scopus 로고
    • Step-Scan FT-IR
    • February
    • R. Palmer, "Step-Scan FT-IR", Journal of Spectroscopy, vol. 8, p. 26, February 1993.
    • (1993) Journal of Spectroscopy , vol.8 , pp. 26
    • Palmer, R.1
  • 10
    • 0005238359 scopus 로고
    • Influence of nonequivalent detector responsivity on FT-IR photometric accuracy
    • M. I. Flik and Z. M. Zhang, "Influence of Nonequivalent Detector Responsivity on FT-IR Photometric Accuracy", Journal of Quantitative Spectroscopy and Radiative Transfer, vol. 42, # 4, pp. 293-303, 1991.
    • (1991) Journal of Quantitative Spectroscopy and Radiative Transfer , vol.42 , Issue.4 , pp. 293-303
    • Flik, M.I.1    Zhang, Z.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.