Volumn 1346, Issue , 1998, Pages 173-185

Improving the reliability of the ceramic-on-ceramic wear couple in THR

Author keywords

Ceramic cup insert; Ceramic liner; Cyclic fatigue; Fracture pattern; Mechanical stability; Resistance to static load; Stress distribution; Total hip replacement

Indexed keywords


EID: 0009985374     PISSN: 00660558     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1520/stp12838s     Document Type: Article
Times cited : (11)

References (7)
  • 2
    • 0345167715 scopus 로고    scopus 로고
    • Ceramic Components for Total Hip Arthroplasty
    • Willmann, G., "Ceramic Components for Total Hip Arthroplasty", Orthopedic Int. 5 (1997) 269-277
    • (1997) Orthopedic Int. , vol.5 , pp. 269-277
    • Willmann, G.1
  • 3
    • 0031239994 scopus 로고    scopus 로고
    • Ceramic cups for total hip replacement, part 3: Osseointegration of monolithic ceramic sockets
    • Willmann, G., "Ceramic cups for total hip replacement, part 3: Osseointegration of monolithic ceramic sockets",. Biomedizinische Technik 42 (1997) 256.263
    • (1997) Biomedizinische Technik , vol.42
    • Willmann, G.1
  • 4
    • 4243956641 scopus 로고    scopus 로고
    • Design Aspects of Modular Inlay Fixation
    • "Performance of the Wear Couple BIOLOX forte in hip arthroplasty W. Puhl, Ed. Enke, Stuttgart
    • nd Symposium on Ceramic Wear Couple, W. Puhl, Ed. Enke, Stuttgart, 1997
    • (1997) nd Symposium on Ceramic Wear Couple
    • Blömer, W.1
  • 5
    • 0345167717 scopus 로고    scopus 로고
    • Recent Innovations Relating to the Use of Ceramic-Ceramic Hip Joint Prostheses
    • W. Puhl, Ed. Enke, Stuttgart
    • Dalla Pria, P., "Recent Innovations Relating to the Use of Ceramic-Ceramic Hip Joint Prostheses", W. Puhl, Ed. "Die Keramikpaarung BIOLOX in der Hüftendoprothetik, Enke, Stuttgart, 1996
    • (1996) Die Keramikpaarung BIOLOX in der Hüftendoprothetik
    • Dalla Pria, P.1
  • 6
    • 85088078856 scopus 로고    scopus 로고
    • Influence of the Ball/Stem-Interface on the load bearing capability of modular total hip endoprostheses
    • Jack E. Parr, Michael B. Mayor, and Donald E. Marlowe, Eds., American Society for Testing and Materials, Philadelphia
    • Richter, H.G., Willmann, G., Wimmer, M. and Osthues, F.G., "Influence of the Ball/Stem-Interface on the load bearing capability of modular total hip endoprostheses", Modularity of Orthopedic Implants, ASTM STP 1301, Jack E. Parr, Michael B. Mayor, and Donald E. Marlowe, Eds., American Society for Testing and Materials, Philadelphia, 1996
    • (1996) Modularity of Orthopedic Implants, ASTM STP 1301
    • Richter, H.G.1    Willmann, G.2    Wimmer, M.3    Osthues, F.G.4
  • 7
    • 0028580088 scopus 로고
    • The Effect of Hardness and Surface Quality of Metal Tapers on the Fracture Load of Ceramic Ball Heads in Hip Endoprostheses
    • Bachnik, M., Hasenpusch, M., et al, "The Effect of Hardness and Surface Quality of Metal Tapers on the Fracture Load of Ceramic Ball Heads in Hip Endoprostheses", Biomedizinische Technik Vol 39, No. 12, 1994, pp 302-306.
    • (1994) Biomedizinische Technik , vol.39 , Issue.12 , pp. 302-306
    • Bachnik, M.1    Hasenpusch, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.