Volumn 32, Issue 5, 1997, Pages 556-564
|
Different quantification approaches for the analysis of biological and environmental samples using inductively coupled plasma mass spectrometry
a a a a a |
Author keywords
Inductively coupled plasma mass spectrometry; Isotope dilution analysis; Molybdenum; Semiquantitative analysis; Sewage sludge; Waters
|
Indexed keywords
MOLYBDENUM;
TRACE METAL;
ACCURACY;
ANALYTICAL ERROR;
ARTICLE;
CALCULATION;
CALIBRATION;
DRUG DETERMINATION;
ENVIRONMENTAL MONITORING;
ISOTOPE DILUTION ASSAY;
MASS SPECTROMETRY;
PRIORITY JOURNAL;
PRODUCTIVITY;
QUANTITATIVE ASSAY;
SLUDGE;
STANDARD;
TECHNIQUE;
WATER ANALYSIS;
CALCIUM;
ENVIRONMENTAL POLLUTANTS;
HEAT;
ISOTOPES;
MASS SPECTROMETRY;
METALS;
MICROWAVES;
MOLYBDENUM;
SEWAGE;
TRACE ELEMENTS;
WATER POLLUTION;
|
EID: 0009605187
PISSN: 10765174
EISSN: None
Source Type: Journal
DOI: 10.1002/(SICI)1096-9888(199705)32:5<556::AID-JMS510>3.0.CO;2-F Document Type: Article |
Times cited : (25)
|
References (18)
|