메뉴 건너뛰기




Volumn 216, Issue 2, 2000, Pages 411-417

Hepatic tumors: Contrast agent-enhancement patterns with pulse-inversion harmonic US

Author keywords

Angioma, gastrointestinal tract; Liver neoplasms; Liver neoplasms, secondary; Liver neoplasms, US; Ultrasound (US), contrast media; Ultrasound (US), harmonic study; Ultrasound (US), technology

Indexed keywords

SHU 508;

EID: 0008158184     PISSN: 00338419     EISSN: None     Source Type: Journal    
DOI: 10.1148/radiology.216.2.r00jl21411     Document Type: Article
Times cited : (249)

References (23)
  • 1
    • 0027496525 scopus 로고
    • Dynamic breath-hold multiplanar spoiled gradient-recalled MR imaging with gadolinium enhancement for differentiating hepatic hemangiomas from malignancies at 1.5 T
    • Whitney WS, Herfkens RJ, Jeffrey RB, et al. Dynamic breath-hold multiplanar spoiled gradient-recalled MR imaging with gadolinium enhancement for differentiating hepatic hemangiomas from malignancies at 1.5 T. Radiology 1993; 189: 863-870.
    • (1993) Radiology , vol.189 , pp. 863-870
    • Whitney, W.S.1    Herfkens, R.J.2    Jeffrey, R.B.3
  • 2
    • 0027993463 scopus 로고
    • Hepatic hemangiomas: A multi-institutional study of appearance on T2-weighted and serial gadolinium-enhanced gradient-echo MR images
    • Semelka RC, Brown ED, Ascher SM, et al. Hepatic hemangiomas: a multi-institutional study of appearance on T2-weighted and serial gadolinium-enhanced gradient-echo MR images. Radiology 1994; 192:401-406.
    • (1994) Radiology , vol.192 , pp. 401-406
    • Semelka, R.C.1    Brown, E.D.2    Ascher, S.M.3
  • 3
    • 0030893845 scopus 로고    scopus 로고
    • Cavernous hemangioma of the liver: Pathologic correlation with dynamic CT findings
    • Yamashita Y, Ogata I, Urata J, Takahashi M. Cavernous hemangioma of the liver: pathologic correlation with dynamic CT findings. Radiology 1997; 203:121-125.
    • (1997) Radiology , vol.203 , pp. 121-125
    • Yamashita, Y.1    Ogata, I.2    Urata, J.3    Takahashi, M.4
  • 4
    • 0344246938 scopus 로고    scopus 로고
    • Limitations of characterization of hepatic hemangiomas using an ultrasound contrast agent (Levovist) and power Doppler ultrasound
    • Kim TK, Han JK, Kim AY, Choi BI. Limitations of characterization of hepatic hemangiomas using an ultrasound contrast agent (Levovist) and power Doppler ultrasound. J Ultrasound Med 1999; 18: 737-743.
    • (1999) J Ultrasound Med , vol.18 , pp. 737-743
    • Kim, T.K.1    Han, J.K.2    Kim, A.Y.3    Choi, B.I.4
  • 5
    • 0032958521 scopus 로고    scopus 로고
    • Doppler sonographic enhancement of hepatic hemangiomas and hepatocellular carcinomas after perflenapent emulsion: Preliminary study
    • Lopez-Ben R, Robbin ML, Weber TM, Smith JK, Needleman L, Berland LL. Doppler sonographic enhancement of hepatic hemangiomas and hepatocellular carcinomas after perflenapent emulsion: preliminary study. J Ultrasound Med 1999; 18:109-116.
    • (1999) J Ultrasound Med , vol.18 , pp. 109-116
    • Lopez-Ben, R.1    Robbin, M.L.2    Weber, T.M.3    Smith, J.K.4    Needleman, L.5    Berland, L.L.6
  • 6
    • 23744475203 scopus 로고    scopus 로고
    • Possibility of differentiating small hyperechoic liver tumours using contrast-enhanced colour Doppler ultrasonography: A preliminary study
    • Tano S, Ueno N, Tomiyama T, Kimura K. Possibility of differentiating small hyperechoic liver tumours using contrast-enhanced colour Doppler ultrasonography: a preliminary study. Clin Radiol 1997; 52:41-45.
    • (1997) Clin Radiol , vol.52 , pp. 41-45
    • Tano, S.1    Ueno, N.2    Tomiyama, T.3    Kimura, K.4
  • 7
    • 0012117843 scopus 로고    scopus 로고
    • Hepatocellular carcinoma: Power Doppler US with a contrast agent - Preliminary results
    • Kim AY, Choi BI, Kim TK, et al. Hepatocellular carcinoma: power Doppler US with a contrast agent - preliminary results. Radiology 1998; 209:135-140.
    • (1998) Radiology , vol.209 , pp. 135-140
    • Kim, A.Y.1    Choi, B.I.2    Kim, T.K.3
  • 8
    • 0031941799 scopus 로고    scopus 로고
    • Value of contrast-enhanced color Doppler sonography in diagnosing hepatocellular carcinoma with special attention to the "color-filled pattern."
    • Tanaka S, Kitamra T, Fujita M, Yoshioka F. Value of contrast-enhanced color Doppler sonography in diagnosing hepatocellular carcinoma with special attention to the "color-filled pattern." J Clin Ultrasound 1998; 26:207-212.
    • (1998) J Clin Ultrasound , vol.26 , pp. 207-212
    • Tanaka, S.1    Kitamra, T.2    Fujita, M.3    Yoshioka, F.4
  • 9
    • 0028052035 scopus 로고
    • Color Doppler sonography of hepatic tumors with a galactose-based contrast agent: Correlation with angiographic findings
    • Fujimoto M, Moriyasu F, Nishikawa K, Nada T, Okuma M. Color Doppler sonography of hepatic tumors with a galactose-based contrast agent: correlation with angiographic findings. AJR Am J Roentgenol 1994; 163:1099-1104.
    • (1994) AJR Am J Roentgenol , vol.163 , pp. 1099-1104
    • Fujimoto, M.1    Moriyasu, F.2    Nishikawa, K.3    Nada, T.4    Okuma, M.5
  • 10
    • 0028260716 scopus 로고
    • Color Doppler ultrasonography in the differential diagnosis of focal hepatic lesions: The SH U 508 A (Levovist) experience
    • Maresca G, Barbaro B, Summaria V, et al. Color Doppler ultrasonography in the differential diagnosis of focal hepatic lesions: the SH U 508 A (Levovist) experience. Radiol Med 1994; 87(suppl):41-49.
    • (1994) Radiol Med , vol.87 , Issue.SUPPL. , pp. 41-49
    • Maresca, G.1    Barbaro, B.2    Summaria, V.3
  • 11
    • 0030059387 scopus 로고    scopus 로고
    • Color Doppler ultrasound of liver lesions: Signal enhancement after intravenous injection of the ultrasound contrast agent Levovist
    • Ernst H, Hahn EG, Balzer T, Schlief R, Heyder N. Color Doppler ultrasound of liver lesions: signal enhancement after intravenous injection of the ultrasound contrast agent Levovist. J Clin Ultrasound 1996; 24:31-35.
    • (1996) J Clin Ultrasound , vol.24 , pp. 31-35
    • Ernst, H.1    Hahn, E.G.2    Balzer, T.3    Schlief, R.4    Heyder, N.5
  • 12
    • 0028314424 scopus 로고
    • Improved sensitivity of colour Doppler flow imaging of colorectal hepatic metastases using galactose microparticles: A preliminary report
    • Leen E, Angerson WJ, Warren HW, et al. Improved sensitivity of colour Doppler flow imaging of colorectal hepatic metastases using galactose microparticles: a preliminary report. Br J Surg 1994; 81: 252-254.
    • (1994) Br J Surg , vol.81 , pp. 252-254
    • Leen, E.1    Angerson, W.J.2    Warren, H.W.3
  • 13
    • 0030028265 scopus 로고    scopus 로고
    • Color amplitude imaging: Preliminary results using vascular sonographic contrast agents
    • Goldberg BB, Merton DA, Forsberg F, Liu JB, Rawool N. Color amplitude imaging: preliminary results using vascular sonographic contrast agents. J Ultrasound Med 1996; 15:127-134.
    • (1996) J Ultrasound Med , vol.15 , pp. 127-134
    • Goldberg, B.B.1    Merton, D.A.2    Forsberg, F.3    Liu, J.B.4    Rawool, N.5
  • 14
    • 0033980281 scopus 로고    scopus 로고
    • Pulse inversion imaging of liver blood flow: Improved method for characterizing focal masses with microbubble contrast
    • Burns PN, Wilson SR, Simpson DH. Pulse inversion imaging of liver blood flow: improved method for characterizing focal masses with microbubble contrast. Invest Radiol 2000; 35:58-71.
    • (2000) Invest Radiol , vol.35 , pp. 58-71
    • Burns, P.N.1    Wilson, S.R.2    Simpson, D.H.3
  • 15
    • 0000623612 scopus 로고    scopus 로고
    • Harmonic interval delay imaging: A new ultrasound contrast method for imaging the blood pool volume in the liver (abstr)
    • Burns PN, Wilson SR, Simpson DH, Chin CT, Lai X. Harmonic interval delay imaging: a new ultrasound contrast method for imaging the blood pool volume in the liver (abstr). Radiology 1998; 209(P):189.
    • (1998) Radiology , vol.209 P , pp. 189
    • Burns, P.N.1    Wilson, S.R.2    Simpson, D.H.3    Chin, C.T.4    Lai, X.5
  • 16
    • 0000024921 scopus 로고    scopus 로고
    • Intermittent US harmonic contrast-enhanced imaging and Doppler improve sensitivity and longevity of vessel detection (abstr)
    • Burns PN, Wilson SR, Muradali D, Powers JE, Fritzsch TT. Intermittent US harmonic contrast-enhanced imaging and Doppler improve sensitivity and longevity of vessel detection (abstr). Radiology 1996; 201(P):159.
    • (1996) Radiology , vol.201 P , pp. 159
    • Burns, P.N.1    Wilson, S.R.2    Muradali, D.3    Powers, J.E.4    Fritzsch, T.T.5
  • 17
    • 0000059936 scopus 로고    scopus 로고
    • Flash echo (passive cavitation) imaging of the liver by using US contrast agents and intermittent scanning sequence (abstr)
    • Moriyasu F, Kono Y, Nada T, Matsumura T, Suginoshita Y, Kobayashi K. Flash echo (passive cavitation) imaging of the liver by using US contrast agents and intermittent scanning sequence (abstr). Radiology 1996; 201(P):196.
    • (1996) Radiology , vol.201 P , pp. 196
    • Moriyasu, F.1    Kono, Y.2    Nada, T.3    Matsumura, T.4    Suginoshita, Y.5    Kobayashi, K.6
  • 18
    • 0031739516 scopus 로고    scopus 로고
    • Tissue harmonic imaging sonography: Evaluation of image quality compared with conventional sonography
    • Shapiro RS, Wagreich J, Parsons RB, Stancato-Pasik A, Yeh HC, Lao R. Tissue harmonic imaging sonography: evaluation of image quality compared with conventional sonography. AJR Am J Roentgenol 1998; 171:1203-1206.
    • (1998) AJR Am J Roentgenol , vol.171 , pp. 1203-1206
    • Shapiro, R.S.1    Wagreich, J.2    Parsons, R.B.3    Stancato-Pasik, A.4    Yeh, H.C.5    Lao, R.6
  • 19
    • 0031057944 scopus 로고    scopus 로고
    • Grayscale second harmonic imaging of the liver with galactose-based microbubbles
    • Kono Y, Moriyasu F, Mine Y, et al. Grayscale second harmonic imaging of the liver with galactose-based microbubbles. Invest Radiol 1997; 32:120-125.
    • (1997) Invest Radiol , vol.32 , pp. 120-125
    • Kono, Y.1    Moriyasu, F.2    Mine, Y.3
  • 20
    • 0001706695 scopus 로고    scopus 로고
    • Microbubble destruction is the origin of harmonic signals from FS069 (abstr)
    • Burns PN, Wilson SR, Muradali D, Powers JE, Fritzsch TT. Microbubble destruction is the origin of harmonic signals from FS069 (abstr). Radiology 1996; 201(P):158.
    • (1996) Radiology , vol.201 P , pp. 158
    • Burns, P.N.1    Wilson, S.R.2    Muradali, D.3    Powers, J.E.4    Fritzsch, T.T.5
  • 21
    • 0000120983 scopus 로고    scopus 로고
    • Investigation of the "flash echo" signal associated with a US contrast agent (abstr)
    • Kamiyama N, Moriyasu F, Kono Y, Mine Y, Nada T, Yamazaki N. Investigation of the "flash echo" signal associated with a US contrast agent (abstr). Radiology 1996; 201(P):158.
    • (1996) Radiology , vol.201 P , pp. 158
    • Kamiyama, N.1    Moriyasu, F.2    Kono, Y.3    Mine, Y.4    Nada, T.5    Yamazaki, N.6
  • 22
    • 0032948352 scopus 로고    scopus 로고
    • Improved imaging of liver metastases with stimulated acoustic emission in the late phase of enhancement with the us contrast agent SH U 508A: Early experience
    • Blomley MJK, Albrecht T, Cosgrove DO, et al. Improved imaging of liver metastases with stimulated acoustic emission in the late phase of enhancement with the US contrast agent SH U 508A: early experience. Radiology 1999; 210:409-416.
    • (1999) Radiology , vol.210 , pp. 409-416
    • Blomley, M.J.K.1    Albrecht, T.2    Cosgrove, D.O.3
  • 23
    • 0016373404 scopus 로고
    • Red blood cell velocity in nailfold capillaries of men, measured by a television microscopy technique
    • Bollinger A, Putti P, Barras JP, et al. Red blood cell velocity in nailfold capillaries of men, measured by a television microscopy technique. Microvasc Res 1974; 7: 61-72.
    • (1974) Microvasc Res , vol.7 , pp. 61-72
    • Bollinger, A.1    Putti, P.2    Barras, J.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.