Volumn 53, Issue 12, 1997, Pages 965-976

Corrosion and Passivity of Ti-13% Nb-13% Zr in Comparison to Other Biomedical Implant Alloys

Author keywords

Biocompatibility; Biomedical implant alloys; Corrosion resistance; Crevice corrosion; Energy dispersive spectroscopy; Hydrochloric acid; Hydrolysis; Niobium; Passivation; Repassivation; Titanium; X ray diffraction; Zirconium

Indexed keywords


EID: 0006724987     PISSN: 00109312     EISSN: None     Source Type: Journal    
DOI: 10.5006/1.3290281     Document Type: Article
Times cited : (239)

References (34)
  • 4
    • 0002604509 scopus 로고
    • Corrosion of Surgical Implant - In Vivo and in Vitro Tests
    • eds. G. Winter, J. Leray, K. de Groot (New York, NY: John Wiley and Sons)
    • S. Steinemann, "Corrosion of Surgical Implant - In Vivo and In Vitro Tests," in Evaluation of Biomaterials, eds. G. Winter, J. Leray, K. de Groot (New York, NY: John Wiley and Sons, 1980), p. 1.
    • (1980) Evaluation of Biomaterials , pp. 1
    • Steinemann, S.1
  • 9
    • 0642376809 scopus 로고
    • Investigation of the Corrosion Resistance and the Electrochemical and Mechanical Properties of Titanium-Niobium Alloys
    • eds. N. Tomashov, E. Nirolybev (Jerusalem, Israel: Israel Program for Scientific Translation)
    • V. Andreeva, V. Kazarin, E. Alekseeva, S. Glasunov, O. Solonia, N. Nikulova, "Investigation of the Corrosion Resistance and the Electrochemical and Mechanical Properties of Titanium-Niobium Alloys," in Corrosion of Metals and Alloys, eds. N. Tomashov, E. Nirolybev (Jerusalem, Israel: Israel Program for Scientific Translation, 1966), p. 34.
    • (1966) Corrosion of Metals and Alloys , pp. 34
    • Andreeva, V.1    Kazarin, V.2    Alekseeva, E.3    Glasunov, S.4    Solonia, O.5    Nikulova, N.6
  • 11
    • 0022991740 scopus 로고
    • Electrochemical Behavior of Titanium and Titanium Alloys with Respect to Their Use as Surgical Implant Materials
    • eds. P. Christel, A. Meunier, A. Lee (Amsterdam, The Netherlands: Elsevier Science Publishers)
    • J. Simpson, "Electrochemical Behavior of Titanium and Titanium Alloys with Respect to Their Use as Surgical Implant Materials," in Biological and Biomedical Performance of Biomaterials, eds. P. Christel, A. Meunier, A. Lee (Amsterdam, The Netherlands: Elsevier Science Publishers, 1986), p. 63.
    • (1986) Biological and Biomedical Performance of Biomaterials , pp. 63
    • Simpson, J.1
  • 13
    • 0002152748 scopus 로고
    • An Overview of Beta Titanium Alloy Environmental Behavior
    • eds. D. Eylon, R. Boyer, D. Koss (Warrendale, PA: TMS)
    • R. Schutz, "An Overview of Beta Titanium Alloy Environmental Behavior," In Beta Titanium Alloys in the 1990s, eds. D. Eylon, R. Boyer, D. Koss (Warrendale, PA: TMS, 1993), p. 75.
    • (1993) Beta Titanium Alloys in the 1990s , pp. 75
    • Schutz, R.1
  • 19
    • 0642380556 scopus 로고
    • Derivation and Application of EMF-pH Diagrams
    • ed. R. Baboian (Houston, TX: NACE)
    • D. Silverman, "Derivation and Application of EMF-pH Diagrams," in Electrochemical Techniques for Corrosion Engineering, ed. R. Baboian (Houston, TX: NACE, 1986), p. 117.
    • (1986) Electrochemical Techniques for Corrosion Engineering , pp. 117
    • Silverman, D.1
  • 23
    • 0042250910 scopus 로고
    • ed. B.F. Brown (Houston, TX: NACE)
    • T.R. Beck, in Localized Corrosion, ed. B.F. Brown (Houston, TX: NACE, 1974), p. 644.
    • (1974) Localized Corrosion , pp. 644
    • Beck, T.R.1
  • 24
    • 0001705753 scopus 로고
    • T.P. Hoar, Proc. Roy. Soc. A294, 1438 (1966), p. 486.
    • (1966) Proc. Roy. Soc. , vol.A294 , Issue.1438 , pp. 486
    • Hoar, T.P.1
  • 30
    • 0002894117 scopus 로고
    • Beta-Titanium Alloys and Their Role in Titanium Industry
    • eds. D. Eylon, R. Boyer, D. Koss (Warrendale, PA: TMS)
    • P.J. Bania, "Beta-Titanium Alloys and Their Role in Titanium Industry," in Beta Titanium Alloys in the 1990s, eds. D. Eylon, R. Boyer, D. Koss (Warrendale, PA: TMS, 1993), p. 4.
    • (1993) Beta Titanium Alloys in the 1990s , pp. 4
    • Bania, P.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.