Volumn 8, Issue 1, 1998, Pages 31-50

Modelling of an X-ray image-intensifier-based radiography system

Author keywords

Image intensifier; Modelling; X ray radiography

Indexed keywords


EID: 0006463567     PISSN: 08953996     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (8)

References (16)
  • 1
    • 0003966099 scopus 로고
    • NBSIR 87-3597 ed., Gaithersburg MD 20899, USA: U.S. Department of Commerce, National Bureau of Standards, Office of Standard Reference Data
    • M.J. Berger and J.H. Hubbell, XCOM: Photon cross Section on a Personal Computer, NBSIR 87-3597 ed., Gaithersburg MD 20899, USA: U.S. Department of Commerce, National Bureau of Standards, Office of Standard Reference Data, 1987.
    • (1987) XCOM: Photon Cross Section on a Personal Computer
    • Berger, M.J.1    Hubbell, J.H.2
  • 3
    • 0019497908 scopus 로고
    • Image information transfer properties of X-ray fluorescent screens
    • C.E. Dick and J.W. Motz, Image information transfer properties of X-ray fluorescent screens, Med. Phys. 8 (1981), 337-346.
    • (1981) Med. Phys. , vol.8 , pp. 337-346
    • Dick, C.E.1    Motz, J.W.2
  • 4
    • 11544353320 scopus 로고
    • Laboratory measuremetns of sensitometry, MTF, veiling glare, Wiener spectrum and DQE for image intensifer tubes
    • R.M. Gagne, C.N. West, R.F. Wagner and P.W. Quinn, Laboratory measuremetns of sensitometry, MTF, veiling glare, Wiener spectrum and DQE for image intensifer tubes, presented at SPIE, 1993.
    • (1993) SPIE
    • Gagne, R.M.1    West, C.N.2    Wagner, R.F.3    Quinn, P.W.4
  • 5
    • 0012032351 scopus 로고    scopus 로고
    • Correction for beam hardening artefacts in computerised tomography
    • this issue
    • P. Hammersberg and M. Mångård, Correction for beam hardening artefacts in computerised tomography, Journal of X-Ray Science and Technology 8(1) (1998), 75-93, this issue.
    • (1998) Journal of X-Ray Science and Technology , vol.8 , Issue.1 , pp. 75-93
    • Hammersberg, P.1    Mångård, M.2
  • 6
    • 0012032556 scopus 로고    scopus 로고
    • Measurements of absolute energy spectra for an industrial micro focal X-ray source under working conditions using a Compton scattering spectrometer
    • this issue
    • P. Hammersberg, M. Stenström, H. Hedtjärn and M. Mångård, Measurements of absolute energy spectra for an industrial micro focal X-ray source under working conditions using a Compton scattering spectrometer, Journal of X-Ray Science and Technology 8(1) (1998), 5-18, this issue.
    • (1998) Journal of X-Ray Science and Technology , vol.8 , Issue.1 , pp. 5-18
    • Hammersberg, P.1    Stenström, M.2    Hedtjärn, H.3    Mångård, M.4
  • 7
    • 0029491784 scopus 로고
    • A theoretical model for determination of the optimal irradiation conditions for computerised tomography
    • P. Hammersberg, M. Stenström, M. Sandborg, G. Matscheko and G. Alm-Carlsson, A theoretical model for determination of the optimal irradiation conditions for computerised tomography, Insight 37 (1995), 978-985.
    • (1995) Insight , vol.37 , pp. 978-985
    • Hammersberg, P.1    Stenström, M.2    Sandborg, M.3    Matscheko, G.4    Alm-Carlsson, G.5
  • 8
    • 0025842995 scopus 로고
    • Signal-to-noise performance in cesium iodide X-ray fluorescent screens
    • W. Hillen, W. Eckenbach, P. Quadflieg and T. Zaengel, Signal-to-noise performance in cesium iodide X-ray fluorescent screens, SPIE. Medical Imaging V 1443 (1991), 120-131.
    • (1991) SPIE. Medical Imaging V , vol.1443 , pp. 120-131
    • Hillen, W.1    Eckenbach, W.2    Quadflieg, P.3    Zaengel, T.4
  • 10
    • 0004493823 scopus 로고    scopus 로고
    • Optimised detail detectability in computersied tomography
    • this issue
    • M. Mångård and P. Hammersberg, Optimised detail detectability in computersied tomography, Journal of X-Ray Science and Technology 8(1) (1998), 51-73, this issue.
    • (1998) Journal of X-Ray Science and Technology , vol.8 , Issue.1 , pp. 51-73
    • Mångård, M.1    Hammersberg, P.2
  • 11
    • 84975561076 scopus 로고
    • Analysis of signal and noise propagation for several imaging mechanisms
    • M. Rabbani and R.V. Metter, Analysis of signal and noise propagation for several imaging mechanisms, J. Opt. Soc. Am. A 6 (1989), 1156-1164.
    • (1989) J. Opt. Soc. Am. A , vol.6 , pp. 1156-1164
    • Rabbani, M.1    Metter, R.V.2
  • 12
    • 0026665727 scopus 로고
    • Influence of X-ray energy spectrum, contrasting detail and detector on the signal-to-noise ratio (SNR) and detective quantum efficiency (DQE) in projection radiography
    • M. Sandborg and G. Alm-Carlsson, Influence of X-ray energy spectrum, contrasting detail and detector on the signal-to-noise ratio (SNR) and detective quantum efficiency (DQE) in projection radiography, Phys. Med. Biol. 37 (1992), 1245-1263.
    • (1992) Phys. Med. Biol. , vol.37 , pp. 1245-1263
    • Sandborg, M.1    Alm-Carlsson, G.2
  • 14
    • 0029458581 scopus 로고
    • Simulation of the imaging performance of X-ray image intensifier/TV camera chains
    • G. Spekowius, H. Boerner, W. Echenbach, P. Quadflieg and G.J. Laurenssen, Simulation of the imaging performance of X-ray image intensifier/TV camera chains, SPIE 2432 (1995), 12-23.
    • (1995) SPIE , vol.2432 , pp. 12-23
    • Spekowius, G.1    Boerner, H.2    Echenbach, W.3    Quadflieg, P.4    Laurenssen, G.J.5
  • 15
    • 0028903253 scopus 로고
    • Evaluation of image quality in fluoroscopy by measurements and Monte Carlo calculations
    • M. Tapiovaara and M. Sandborg, Evaluation of image quality in fluoroscopy by measurements and Monte Carlo calculations, Phys. Med. Biol. 40 (1995), 589-607.
    • (1995) Phys. Med. Biol. , vol.40 , pp. 589-607
    • Tapiovaara, M.1    Sandborg, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.