메뉴 건너뛰기




Volumn 23, Issue 4, 2000, Pages 432-443

Miniature Cone Penetration Tests in Soft and Stiff Clays

Author keywords

Clay soil; Cone penetration test; Miniature cone penetrometer; Scale effect; Site characterization

Indexed keywords

CLAY; HIGHWAY PLANNING; SOFTWARE TESTING;

EID: 0006408691     PISSN: 01496115     EISSN: None     Source Type: Journal    
DOI: 10.1520/gtj11064j     Document Type: Article
Times cited : (27)

References (14)
  • 1
    • 0010896857 scopus 로고
    • Profiling the Overconsolidation Ratio of Clay by Piezocone Tests
    • Georgia Tech Research Corporation and Georgia Institute of Technology, School of Civil & Environmental Eng., Atlanta, GA
    • Chen, B. S. and Mayne, P. W., 1994, "Profiling the Overconsolidation Ratio of Clay by Piezocone Tests," Report GIT-CEE-GEO-94-1. Georgia Tech Research Corporation and Georgia Institute of Technology, School of Civil & Environmental Eng., Atlanta, GA.
    • (1994) Report GIT-CEE-GEO-94-1
    • Chen, B.S.1    Mayne, P.W.2
  • 2
    • 0025797817 scopus 로고
    • Scale Effects in Cone Penetration Tests
    • ASCE GSP Boulder, CO
    • de Lima, D. C. and Tumay, M. T., 1991, "Scale Effects in Cone Penetration Tests," Geotechnical Engineering Congress, ASCE GSP No. 27, Boulder, CO, pp. 38-51.
    • (1991) Geotechnical Engineering Congress , vol.27 , pp. 38-51
    • De Lima, D.C.1    Tumay, M.T.2
  • 10
    • 0043224695 scopus 로고
    • Calibration and Implementation of Miniature Electric Cone Penetrometer and Development, Fabrication and Verification of the LSU in Situ Testing Calibration Chamber (LSU/CALCHAS)
    • Department of Civil Engineering, Louisiana State University, Baton Rouge, LA
    • Tumay, M. T. and de Lima, D. C., 1992, "Calibration and Implementation of Miniature Electric Cone Penetrometer and Development, Fabrication and Verification of the LSU In Situ Testing Calibration Chamber (LSU/CALCHAS)," Report GE-92/08. Department of Civil Engineering, Louisiana State University, Baton Rouge, LA.
    • (1992) Report GE-92/08
    • Tumay, M.T.1    De Lima, D.C.2
  • 11
    • 0042723383 scopus 로고    scopus 로고
    • A Continuous Intrusion Electronic Miniature Cone Penetration Test System for Site Characterization
    • Atlanta, Robertson & Mayne, Eds., Balkema
    • Tumay, M. T., Kurup, P. U., and Boggess, R. L., 1998, "A Continuous Intrusion Electronic Miniature Cone Penetration Test System for Site Characterization," Proceedings of the First International Conference on Site Characterization-ISC'98, Atlanta, Robertson & Mayne, Eds., Balkema, Vol. 2, pp. 1183-1188.
    • (1998) Proceedings of the First International Conference on Site Characterization-ISC'98 , vol.2 , pp. 1183-1188
    • Tumay, M.T.1    Kurup, P.U.2    Boggess, R.L.3
  • 12
    • 0344307214 scopus 로고    scopus 로고
    • Calibration and Implementation of Miniature Electronic Cone Penetrometers for Road and Highway Design and Construction
    • Louisiana Transportation Research Center, Baton Rouge, LA
    • Tumay, M. T. and Kurup, P. U., 1997, "Calibration and Implementation of Miniature Electronic Cone Penetrometers for Road and Highway Design and Construction," Report FHWA/ LA.97/305. Louisiana Transportation Research Center, Baton Rouge, LA.
    • (1997) Report FHWA/ LA.97/305
    • Tumay, M.T.1    Kurup, P.U.2
  • 13
    • 0042723437 scopus 로고
    • Implementation of Louisiana Electric Cone Penetrometer System (LECOPS) for Design of Transportation Facilities, Executive Summary
    • Baton Rouge, LA
    • Tumay, M. T., 1994, "Implementation of Louisiana Electric Cone Penetrometer System (LECOPS) for Design of Transportation Facilities, Executive Summary," Report No. FHWA/LA-94/280 A&B. LTRC, Baton Rouge, LA.
    • (1994) Report No. FHWA/LA-94/280 A&B. LTRC
    • Tumay, M.T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.