메뉴 건너뛰기




Volumn 37, Issue 8, 1998, Pages 2258-2267

Three-dimensional monochromatic x-ray computed tomography using synchrotron radiation

(10)  Saito, Tsuneo a,b,g,h,i,j   Kudo, Hiroyuki b,g,h,j,k,l   Takeda, Tohru a,b   Itai, Yuji b,m,n   Tokumori, Kenji c   Toyofuku, Fukai c   Hyodo, Kazuyuki d   Ando, Masami d   Nishimura, Katsuyuki e   Uyama, Chikao f  

a SPIE   (Japan)

Author keywords

3D image reconstruction algorithm; Cone beam 3D CT; Energy subtraction imaging; Monochromatic x ray CT; Synchrotron radiation; Volume imaging

Indexed keywords


EID: 0005512028     PISSN: 00913286     EISSN: None     Source Type: Journal    
DOI: 10.1117/1.601745     Document Type: Article
Times cited : (4)

References (20)
  • 1
    • 0020764170 scopus 로고
    • An inversion formula for cone-beam reconstruction
    • H. K. Tuy, "An inversion formula for cone-beam reconstruction," SIAM J. Appl. Math. 43, 546-552 (1983).
    • (1983) SIAM J. Appl. Math. , vol.43 , pp. 546-552
    • Tuy, H.K.1
  • 2
    • 0022026907 scopus 로고
    • Image reconstruction from cone-beam projections: Necessary and sufficient conditions and reconstruction methods
    • B. D. Smith, "Image reconstruction from cone-beam projections: necessary and sufficient conditions and reconstruction methods," IEEE Trans. Med. Imaging MI-4(1), 14-25 (1985).
    • (1985) IEEE Trans. Med. Imaging , vol.MI-4 , Issue.1 , pp. 14-25
    • Smith, B.D.1
  • 3
    • 0025429744 scopus 로고
    • Cone-beam tomography: Recent advance and a tutorial review
    • B. D. Smith, "Cone-beam tomography: recent advance and a tutorial review," Opt. Eng. 29(5), 524-534 (1990).
    • (1990) Opt. Eng. , vol.29 , Issue.5 , pp. 524-534
    • Smith, B.D.1
  • 4
    • 0002018761 scopus 로고
    • Mathematical framework of cone beam 3D reconstruction via first derivative of the Radon transform
    • G. T. Herman, A. K. Louis, and F. Natterer, Eds., Springer-Verlag, Berlin
    • P. Grangeat, "Mathematical framework of cone beam 3D reconstruction via first derivative of the Radon transform," in Lecture Notes in Mathematics 1497, G. T. Herman, A. K. Louis, and F. Natterer, Eds., pp. 66-97 Springer-Verlag, Berlin (1991).
    • (1991) Lecture Notes in Mathematics 1497 , pp. 66-97
    • Grangeat, P.1
  • 5
    • 0028397603 scopus 로고
    • Derivation and implementation of a cone-beam reconstruction algorithm for nonplanar orbit
    • H. Kudo and T. Saito, "Derivation and implementation of a cone-beam reconstruction algorithm for nonplanar orbit," IEEE Trans. Med. Imaging MI-13(1), 196-211 (1994).
    • (1994) IEEE Trans. Med. Imaging , vol.MI-13 , Issue.1 , pp. 196-211
    • Kudo, H.1    Saito, T.2
  • 6
    • 0028392621 scopus 로고
    • A cone-beam reconstruction algorithm using shift-variant filtering and cone-beam backprojection
    • M. Defries and R. Clack, "A cone-beam reconstruction algorithm using shift-variant filtering and cone-beam backprojection," IEEE Trans. Med. Imaging MI-13, 186-195 (1994).
    • (1994) IEEE Trans. Med. Imaging , vol.MI-13 , pp. 186-195
    • Defries, M.1    Clack, R.2
  • 7
    • 0028750824 scopus 로고
    • Overview of reconstruction algorithm for exact cone-beam tomography
    • C. Clack and M. Defries, "Overview of reconstruction algorithm for exact cone-beam tomography," Proc. SPIE 2299, 230-241 (1994).
    • (1994) Proc. SPIE , vol.2299 , pp. 230-241
    • Clack, C.1    Defries, M.2
  • 8
    • 0026552271 scopus 로고
    • A cone-beam tomography algorithm for orthogonal circle-and-line orbit
    • G. L. Zeng and G. T. Gullberg, "A cone-beam tomography algorithm for orthogonal circle-and-line orbit," Phys. Med. Biol., 37, 563-577 (1992).
    • (1992) Phys. Med. Biol. , vol.37 , pp. 563-577
    • Zeng, G.L.1    Gullberg, G.T.2
  • 10
    • 0020753453 scopus 로고
    • Computed tomography using synchrotron radiation
    • A. C. Thompson et al., "Computed tomography using synchrotron radiation," Nucl. Instrum. Methods Phys. Res. 222, 319-323 (1984).
    • (1984) Nucl. Instrum. Methods Phys. Res. , vol.222 , pp. 319-323
    • Thompson, A.C.1
  • 11
    • 38249019902 scopus 로고
    • Sensitivities for contrast agent imaging in CT scans using single energy synchrotron radiation
    • K. J. McCarthy and J. Fryar, "Sensitivities for contrast agent imaging in CT scans using single energy synchrotron radiation," Nucl. Instrum. Methods Phys. Res. A287, 613-618 (1986).
    • (1986) Nucl. Instrum. Methods Phys. Res. , vol.A287 , pp. 613-618
    • McCarthy, K.J.1    Fryar, J.2
  • 13
    • 0023828864 scopus 로고
    • Improvement of spatial resolution of monochromatic x-ray CT using synchrotron radiation
    • K. Sakamoto, Y. Suzuki, T. Hirano, and K. Usami, "Improvement of spatial resolution of monochromatic x-ray CT using synchrotron radiation," Jpn. J. Appl. Phys. 27(1), 127-132 (1988).
    • (1988) Jpn. J. Appl. Phys. , vol.27 , Issue.1 , pp. 127-132
    • Sakamoto, K.1    Suzuki, Y.2    Hirano, T.3    Usami, K.4
  • 14
    • 0029216272 scopus 로고
    • An extended completeness condition for exact cone-beam reconstruction and application
    • IEEE, New York
    • H. Kudo and T. Saito, "An extended completeness condition for exact cone-beam reconstruction and application," in Proc. IEEE Nuclear Science Symp. and Medical Imaging Conf., pp. 1710-1714, IEEE, New York (1994).
    • (1994) Proc. IEEE Nuclear Science Symp. and Medical Imaging Conf. , pp. 1710-1714
    • Kudo, H.1    Saito, T.2
  • 15
    • 0039202891 scopus 로고
    • Development of a fluorescent x-ray source for medical imaging
    • F. Toyofuku et al., "Development of a fluorescent x-ray source for medical imaging," Rev. Sci. Instrum. 66(Part II), 1981-1983 (1995).
    • (1995) Rev. Sci. Instrum. , vol.66 , Issue.2 PART , pp. 1981-1983
    • Toyofuku, F.1
  • 19
    • 0029543772 scopus 로고
    • Three-dimensional monochromatic x-ray CT
    • T. Saito et al., "Three-dimensional monochromatic x-ray CT," Proc. SPIE 2564, 548-557 (1995).
    • (1995) Proc. SPIE , vol.2564 , pp. 548-557
    • Saito, T.1
  • 20
    • 0000177203 scopus 로고
    • Computed tomography with monochromatic x rays from the national synchrotron light source
    • F. A. Dilmanian et al., "Computed tomography with monochromatic x rays from the national synchrotron light source," Nucl. Instrum. Methods Phys. Res. B56/57, 1208-1213 (1991).
    • (1991) Nucl. Instrum. Methods Phys. Res. , vol.57 B56 , pp. 1208-1213
    • Dilmanian, F.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.