메뉴 건너뛰기




Volumn 1301, Issue , 1997, Pages 114-126

Assessing morse taper function : The relationship between impaction force, disassembly force, and design variables

Author keywords

Femoral component; Modularity; Morse taper; Total hip arthroplasty

Indexed keywords


EID: 0005267554     PISSN: 00660558     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1520/stp12026s     Document Type: Article
Times cited : (22)

References (28)
  • 3
    • 0025278251 scopus 로고
    • Disassembly of a Modular Femoral Component during Closed Reduction of the Dislocated Femoral Component: A Case Report
    • Pellicci, P. M., and Haas, S.B., "Disassembly of a Modular Femoral Component During Closed Reduction of the Dislocated Femoral Component: a Case Report," The Journal of Bone and Joint Surgery, 72A: 619-620, 1990.
    • (1990) The Journal of Bone and Joint Surgery , vol.72 A , pp. 619-620
    • Pellicci, P.M.1    Haas, S.B.2
  • 4
    • 0025265994 scopus 로고
    • Disassembly of a Modular Femoral Prosthesis after Dislocation of the Femoral Component: A Case Report
    • Woolson, S. T., and Pottorff, G. T., "Disassembly of a Modular Femoral Prosthesis After Dislocation of the Femoral Component: a Case Report," The Journal of Bone and Joint Surgery, 72A: 624-625, 1990.
    • (1990) The Journal of Bone and Joint Surgery , vol.72 A , pp. 624-625
    • Woolson, S.T.1    Pottorff, G.T.2
  • 20
    • 0028073911 scopus 로고
    • Migration of Corrosion Products from Modular Hip Prostheses: Particle Microanalysis and Histopathological Findings
    • Urban R. M., Jacobs J. J., Gilbert J. L., and Galante J. O., "Migration of Corrosion Products From Modular Hip Prostheses: Particle Microanalysis and Histopathological Findings," The Journal of Bone and Joint Surgery, 76A: 1345-59, 1994.
    • (1994) The Journal of Bone and Joint Surgery , vol.76 A , pp. 1345-1359
    • Urban, R.M.1    Jacobs, J.J.2    Gilbert, J.L.3    Galante, J.O.4
  • 22
    • 0026443407 scopus 로고
    • Current Biomaterials Problems in Implants
    • ed. Robert E. Eilert, Chapter 14
    • Skinner, H.B., "Current Biomaterials Problems in Implants," In AAOS Instructional Course Lectures, ed. Robert E. Eilert, Vol. XLI, Chapter 14, pp. 137-139, 1992.
    • (1992) AAOS Instructional Course Lectures , vol.41 , pp. 137-139
    • Skinner, H.B.1
  • 23
    • 0005381771 scopus 로고
    • Axial Pull-off Strength of Dry and Wet Taper Head Connections on a Modular Shoulder Prosthesis
    • Feb. 22
    • Loch, D. A., Gleason, K. A., Kyle, R. F., and Bechtold, J.E., "Axial Pull-off Strength of Dry and Wet Taper Head Connections on a Modular Shoulder Prosthesis," Presented at Orthopaedic Research Society, Feb. 22, 1994.
    • (1994) Orthopaedic Research Society
    • Loch, D.A.1    Gleason, K.A.2    Kyle, R.F.3    Bechtold, J.E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.