메뉴 건너뛰기




Volumn 75, Issue 3, 1996, Pages 57-62

Brazing of dispersion-strengthened aluminum the sessile drop test was used to investigate the wetting behavior of Al-Si brazing alloys on dispersion-strengthened aluminum. The Sessile drop test was used to investigate the wetting behavior of Al-Si brazing alloys on dispersion-strenthened aluminum

Author keywords

[No Author keywords available]

Indexed keywords

ALUMINUM ALLOYS; BRAZING FILLER METALS; COMPOSITION; CRACK INITIATION; EUTECTICS; GRAIN BOUNDARIES; HARDNESS; MECHANICAL PROPERTIES; MECHANICAL VARIABLES MEASUREMENT; METALLOGRAPHIC MICROSTRUCTURE; METALLOGRAPHY; WETTING;

EID: 0004863870     PISSN: 00432296     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (2)

References (14)
  • 4
    • 18544364651 scopus 로고    scopus 로고
    • Anisdahl, L., and Hove, I. 1993. Memos to Raufoss Technology AS, SINTEF, Materials Technology, Oslo, Norway. (08-13,12-14)
    • Anisdahl, L., and Hove, I. 1993. Memos to Raufoss Technology AS, SINTEF, Materials Technology, Oslo, Norway. (08-13,12-14).
  • 5
    • 18544369643 scopus 로고    scopus 로고
    • Hellum, E. 1994. Raufoss Technology AS, Norway, Unpublished work
    • Hellum, E. 1994. Raufoss Technology AS, Norway, Unpublished work.
  • 8
    • 18544368871 scopus 로고    scopus 로고
    • U.S. Patent 3,3221,828, 30-5-1967
    • Miller, C. J. U.S. Patent 3,3221,828, 30-5-1967.
    • Miller, C.J.1