메뉴 건너뛰기




Volumn 57, Issue 1-3, 1999, Pages 115-119

Adsorbed water as key to room temperature gas-sensitive reactions in work function type sensors: the carbonate-carbon dioxide system

Author keywords

[No Author keywords available]

Indexed keywords

ADSORPTION; CARBON DIOXIDE; CARBONATES; FOURIER TRANSFORM INFRARED SPECTROSCOPY; PROBES; SOLUBILITY; THICK FILMS; THIN FILMS; WATER;

EID: 0004746856     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0925-4005(99)00062-3     Document Type: Article
Times cited : (29)

References (11)
  • 1
    • 0342498431 scopus 로고
    • Microsensors based on modulation of work function
    • in: Kluwer Academic Publishers (Ed.), Sensors and sensor systems for an electronic nose, of NATO ASI Series E
    • J. Janata, Microsensors based on modulation of work function, in: Kluwer Academic Publishers (Ed.), Sensors and sensor systems for an electronic nose, Proceedings of the NATO advanced research workshop, Vol. 212 of NATO ASI Series E, 1992, pp. 103-116.
    • (1992) Proceedings of the NATO Advanced Research Workshop , vol.212 , pp. 103-116
    • Janata, J.1
  • 2
    • 0022136282 scopus 로고
    • The impact of MOSFET-based sensors
    • Bergveld P. The impact of MOSFET-based sensors. Sensors and Actuators. 8:1985;109-127.
    • (1985) Sensors and Actuators , vol.8 , pp. 109-127
    • Bergveld, P.1
  • 3
    • 23544482324 scopus 로고
    • Ueber Kolloide Loesungen der Erdalkalikarbonate I
    • Buzägh A.V. Ueber Kolloide Loesungen der Erdalkalikarbonate I. Koll. Zeitschrift. 38:1925;222.
    • (1925) Koll. Zeitschrift , vol.38 , pp. 222
    • Buzägh, A.V.1
  • 4
    • 0016980534 scopus 로고
    • Piezoelectric driven Kelvin probe for contact potential measurements
    • Besocke K., Berger S. Piezoelectric driven Kelvin probe for contact potential measurements. Rev. Sci. Instrum. 477:1976;840-842.
    • (1976) Rev. Sci. Instrum. , vol.477 , pp. 840-842
    • Besocke, K.1    Berger, S.2
  • 11
    • 0041543728 scopus 로고    scopus 로고
    • Ozon detection in the ppb range with work function sensors operating at room temperature
    • Doll Th., Lechner J., Eisele I., Schierbaum K.D., Göpel W. Ozon detection in the ppb range with work function sensors operating at room temperature. Sensors and Actuators B. 34:1996;506-510.
    • (1996) Sensors and Actuators B , vol.34 , pp. 506-510
    • Doll, Th.1    Lechner, J.2    Eisele, I.3    Schierbaum, K.D.4    Göpel, W.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.