메뉴 건너뛰기




Volumn 5, Issue 3, 1996, Pages 170-180

Effect of Combined Heat and Moisture Transfer on the Predicted Indoor Thermal Environment

Author keywords

Computational fluid dynamics; Condensation; Moisture transfer; Radiation heat transfer; Thermal comfort

Indexed keywords


EID: 0004557333     PISSN: 1420326X     EISSN: None     Source Type: Journal    
DOI: 10.1159/000463706     Document Type: Article
Times cited : (6)

References (27)
  • 1
    • 2842612623 scopus 로고
    • Energy Conservation in Buildings and Community Systems, Annex XIV - Condensation and Energy
    • Sourcebook, March
    • International Energy Agency: Energy Conservation in Buildings and Community Systems, Annex XIV - Condensation and Energy. Final Report, vol 1 : Sourcebook, March 1991.
    • (1991) Final Report , vol.1
  • 2
    • 0003474886 scopus 로고
    • Atlanta, American Society of Heating, Refrigeration and Air-Conditioning Engineers
    • ASHRAE Handbook of Fundamentals. Atlanta, American Society of Heating, Refrigeration and Air-Conditioning Engineers, 1989.
    • (1989) ASHRAE Handbook of Fundamentals
  • 3
    • 0010119143 scopus 로고
    • London, Chartered Institution of Building Services Engineers
    • CIBSE Guide A. London, Chartered Institution of Building Services Engineers, 1986.
    • (1986) CIBSE Guide A
  • 4
    • 0026986274 scopus 로고
    • Study of the effects of solar radiation on the indoor environment
    • Athienitis AK, Haghighat F: Study of the effects of solar radiation on the indoor environment, ASHRAE Trans 1992;98:257-261.
    • (1992) ASHRAE Trans , vol.98 , pp. 257-261
    • Athienitis, A.K.1    Haghighat, F.2
  • 5
    • 0008476380 scopus 로고
    • Internal long-wave radiation exchange in buildings: Comparison of calculation methods
    • Stefanizzi P, Wilson A, Pinney A: Internal long-wave radiation exchange in buildings: Comparison of calculation methods, Build Serv Eng Res Technol, 1990;11:87-96.
    • (1990) Build Serv Eng Res Technol , vol.11 , pp. 87-96
    • Stefanizzi, P.1    Wilson, A.2    Pinney, A.3
  • 6
    • 0029213335 scopus 로고
    • Radiant heat exchange calculations in radiantly heated and cooled enclosures
    • Chapman KS, Zhang P: Radiant heat exchange calculations in radiantly heated and cooled enclosures, ASHRAE Trans 1995;101:1236-1247.
    • (1995) ASHRAE Trans , vol.101 , pp. 1236-1247
    • Chapman, K.S.1    Zhang, P.2
  • 7
    • 2842553730 scopus 로고
    • A methodology for indoor airflow computations and energy analysis for a displacement ventilation system
    • Chen Q, van der Kooi J: A methodology for indoor airflow computations and energy analysis for a displacement ventilation system. Energy Build 1990;14:259-271.
    • (1990) Energy Build , vol.14 , pp. 259-271
    • Chen, Q.1    Van der Kooi, J.2
  • 10
    • 2842545988 scopus 로고
    • Airflow and thermal comfort in naturally ventilated classrooms
    • Ottawa, September
    • Gan G, Awbi HB, Croome DJ: Airflow and thermal comfort in naturally ventilated classrooms, Proceedings 12th AIVC Conference, Ottawa, September 1991, vol 3, pp 161-177.
    • (1991) Proceedings 12th AIVC Conference , vol.3 , pp. 161-177
    • Gan, G.1    Awbi, H.B.2    Croome, D.J.3
  • 11
    • 0027878219 scopus 로고
    • Numerical prediction of airflow and heat-radiation interaction in a room with displacement ventilation
    • Li Y, Fuchs L, Sandberg M: Numerical prediction of airflow and heat-radiation interaction in a room with displacement ventilation. Energy Build 1993;20:27-43.
    • (1993) Energy Build , vol.20 , pp. 27-43
    • Li, Y.1    Fuchs, L.2    Sandberg, M.3
  • 12
    • 0026961707 scopus 로고
    • Numerical prediction of moisture condensation on curtain walls using the finite-element method and its experimental validation
    • Han H, Khuinsky BM, Crooks B: Numerical prediction of moisture condensation on curtain walls using the finite-element method and its experimental validation, ASHRAE Trans 1992;98:574-583.
    • (1992) ASHRAE Trans , vol.98 , pp. 574-583
    • Han, H.1    Khuinsky, B.M.2    Crooks, B.3
  • 13
    • 0027294427 scopus 로고
    • Fundamental understanding of surface sweating
    • Khanpara JC, Behrens EW: Fundamental understanding of surface sweating, ASHRAE Trans, 1993;99:265-269.
    • (1993) ASHRAE Trans , vol.99 , pp. 265-269
    • Khanpara, J.C.1    Behrens, E.W.2
  • 14
    • 0029235741 scopus 로고
    • Numerical prediction of window condensation potential
    • McGowan AG: Numerical prediction of window condensation potential, ASHRAE Trans 1995;101:832-837.
    • (1995) ASHRAE Trans , vol.101 , pp. 832-837
    • McGowan, A.G.1
  • 15
    • 0025590452 scopus 로고
    • Modelling of moisture transfer in structures. I. A description of a finite-difference nodal model
    • Cunningham M J: Modelling of moisture transfer in structures. I. A description of a finite-difference nodal model. Build Environ 1990;25:55-61.
    • (1990) Build Environ , vol.25 , pp. 55-61
    • Cunningham, M.J.1
  • 16
    • 0028468876 scopus 로고
    • Transient analysis of air-conditioning load and room conditions considering simultaneous heat and moisture transport of multi-layered constructions
    • Yoshida H, Terai T, Sueyoshi H: Transient analysis of air-conditioning load and room conditions considering simultaneous heat and moisture transport of multi-layered constructions, Build Environ 1994;29:337-343.
    • (1994) Build Environ , vol.29 , pp. 337-343
    • Yoshida, H.1    Terai, T.2    Sueyoshi, H.3
  • 17
    • 0027037825 scopus 로고
    • Modelling of indoor air humidity - The dynamic behaviour within an enclosure
    • El Diasty R, Fazio P, Budaiwi I: Modelling of indoor air humidity - the dynamic behaviour within an enclosure. Energy Build 1992;19:61-73.
    • (1992) Energy Build , vol.19 , pp. 61-73
    • El Diasty, R.1    Fazio, P.2    Budaiwi, I.3
  • 18
    • 0027306902 scopus 로고
    • Dynamic modelling of air humidity behaviour in a multi-zone space
    • ElDiasty R, Fazio P, Budaiwi I: Dynamic modelling of air humidity behaviour in a multi-zone space. Build Environ 1993;28:33-51.
    • (1993) Build Environ , vol.28 , pp. 33-51
    • ElDiasty, R.1    Fazio, P.2    Budaiwi, I.3
  • 19
    • 0023843678 scopus 로고
    • Room air moisture content: Dynamic effects of ventilation and vapour generation
    • Letherman KM: Room air moisture content: Dynamic effects of ventilation and vapour generation. Build Serv Eng Res Technol 1988;9:49-53.
    • (1988) Build Serv Eng Res Technol , vol.9 , pp. 49-53
    • Letherman, K.M.1
  • 20
    • 0001264339 scopus 로고
    • Numerical method for a full assessment of indoor thermal comfort
    • Gan G: Numerical method for a full assessment of indoor thermal comfort. Indoor Air 1994;4:154-168.
    • (1994) Indoor Air , vol.4 , pp. 154-168
    • Gan, G.1
  • 24
    • 0018480361 scopus 로고
    • A stable and accurate convective modelling procedure based on quadratic upstream interpolation
    • Leonard BP: A stable and accurate convective modelling procedure based on quadratic upstream interpolation. Comput Methods Appl Mech Eng 1979;19:59-98.
    • (1979) Comput Methods Appl Mech Eng , vol.19 , pp. 59-98
    • Leonard, B.P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.