메뉴 건너뛰기




Volumn 6, Issue 3, 1997, Pages 160-167

Ventilation Performance and Indoor Air Quality in Workstations under Different Supply Air Systems: A Numerical Approach

Author keywords

Computational fluid dynamics; Indoor air quality; Numerical approach; Ventilation; Workstation

Indexed keywords


EID: 0004432444     PISSN: 1420326X     EISSN: None     Source Type: Journal    
DOI: 10.1177/1420326X9700600306     Document Type: Article
Times cited : (6)

References (13)
  • 1
    • 0000349643 scopus 로고    scopus 로고
    • The influence of office furniture, workstation, diffuser types and location on indoor air quality and thermal comfort conditions in workstation
    • Haghighat F, Hou Y, Zhang J, Shaw J: The influence of office furniture, workstation, diffuser types and location on indoor air quality and thermal comfort conditions in workstation. Indoor Air 1996;6:188-203.
    • (1996) Indoor Air , vol.6 , pp. 188-203
    • Haghighat, F.1    Hou, Y.2    Zhang, J.3    Shaw, J.4
  • 3
    • 0026622191 scopus 로고
    • Thermal comfort and indoor air quality in a partitioned enclosure under mixed convection
    • Jiang Z: Thermal comfort and indoor air quality in a partitioned enclosure under mixed convection. Build Environ 1992;27:77-84.
    • (1992) Build Environ , vol.27 , pp. 77-84
    • Jiang, Z.1
  • 4
    • 84909785129 scopus 로고
    • A numerical study of indoor air quality and thermal comfort under six kinds of air diffusion
    • Chen Q, Moser A, Suter P: A numerical study of indoor air quality and thermal comfort under six kinds of air diffusion. ASHRAE Trans 1992;97(Pt 2):33-42.
    • (1992) ASHRAE Trans , vol.97 , Issue.2 PART , pp. 33-42
    • Chen, Q.1    Moser, A.2    Suter, P.3
  • 6
    • 33748327908 scopus 로고
    • Comparison between three air distribution systems for operating rooms
    • Oslo, NORSK VVS. session 2-2
    • Hillerbrant B, Ljungqvist B: Comparison between three air distribution systems for operating rooms. Proceedings of ROOMVENT'90, Oslo, NORSK VVS. 1990: session 2-2.
    • (1990) Proceedings of ROOMVENT'90
    • Hillerbrant, B.1    Ljungqvist, B.2
  • 7
    • 0043076727 scopus 로고
    • A CFD analysis of ventilation effectiveness in a partitioned room
    • Haghighat F, Jiang Z, Wang JCY: A CFD analysis of ventilation effectiveness in a partitioned room. Indoor Air 1991;1:606-615.
    • (1991) Indoor Air , vol.1 , pp. 606-615
    • Haghighat, F.1    Jiang, Z.2    Wang, J.C.Y.3
  • 8
    • 0000231307 scopus 로고
    • Comparison of displacement and mixing diffusers
    • Jiang Z, Chen Q, Moser A: Comparison of displacement and mixing diffusers. Indoor Air 1992;2:168-179.
    • (1992) Indoor Air , vol.2 , pp. 168-179
    • Jiang, Z.1    Chen, Q.2    Moser, A.3
  • 9
    • 0026866170 scopus 로고
    • Air movement in buildings using computational fluid dynamics
    • Transactions of the ASME
    • Haghighat F, Jiang Z, Wang JCY, Allard F: Air movement in buildings using computational fluid dynamics. Transactions of the ASME. J Solar Energy Eng 1992;114:84-92.
    • (1992) J Solar Energy Eng , vol.114 , pp. 84-92
    • Haghighat, F.1    Jiang, Z.2    Wang, J.C.Y.3    Allard, F.4
  • 12
    • 0020940765 scopus 로고
    • The use of moments for assessing air quality
    • Sandberg M, Sjoberg M: The use of moments for assessing air quality. Build Environ 1983;18:181-197.
    • (1983) Build Environ , vol.18 , pp. 181-197
    • Sandberg, M.1    Sjoberg, M.2
  • 13
    • 0343727585 scopus 로고
    • The new equation for indoor air quality, the human equation: Health and comfort
    • ASHRAE, San Diego
    • Fanger PO: The new equation for indoor air quality, the human equation: health and comfort. Proceedings of IAQ 89, ASHRAE, San Diego, 1990, pp.251-254.
    • (1990) Proceedings of IAQ 89 , pp. 251-254
    • Fanger, P.O.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.