메뉴 건너뛰기




Volumn 2978, Issue , 1997, Pages 172-179

Complexity and performance of on-chip biochemical assays

Author keywords

Biochemical assay; Competitive binding assay; Dilution series; Fraction collection; Microchip

Indexed keywords

ASSAYS; BINDING SITES; MECHANICAL ENGINEERING; MECHANICS; MECHATRONICS; MICROPROCESSOR CHIPS;

EID: 0003686794     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.269974     Document Type: Conference Paper
Times cited : (5)

References (11)
  • 1
    • 11944262834 scopus 로고
    • Capillary electrophoresis and sample injection systems integrated on a planar glass chip
    • D.J. Harrison, A. Manz, Z. Fan, H. Ludi, H. M. Widmer, "Capillary electrophoresis and sample injection systems integrated on a planar glass chip," Anal. Chem., 64 (1992) 1926-1932.
    • (1992) Anal. Chem , vol.64 , pp. 1926-1932
    • Harrison, D.J.1    Manz, A.2    Fan, Z.3    Ludi, H.4    Widmer, H.M.5
  • 2
    • 0342507903 scopus 로고
    • Micromachining a miniaturized capillary electrophoresis-based chemical analysis system on a chip
    • D.J. Harrison, K.Fluri, K. Seiler, Z. Fan, C. S. Effenhauser, A. Manz, "Micromachining a miniaturized capillary electrophoresis-based chemical analysis system on a chip," Science, 261, pp. 895-897, 1993.
    • (1993) Science , vol.261 , pp. 895-897
    • Harrison, D.J.1    Fluri, K.2    Seiler, K.3    Fan, Z.4    Effenhauser, C.S.5    Manz, A.6
  • 3
    • 0028407532 scopus 로고
    • Effects of injection schemes and column geometry on the performance of microchip electrophoresis devices
    • S.C. Jacobson et al., "Effects of injection schemes and column geometry on the performance of microchip electrophoresis devices," Anal. Chem., 66 , pp. 1107-1113, 1994.
    • (1994) Anal. Chem , vol.66 , pp. 1107-1113
    • Jacobson, S.C.1
  • 5
    • 2842550379 scopus 로고    scopus 로고
    • Integrated microdevice for DNA restiction fragment analysis
    • S.C. Jacobson and J.M. Ramsey, "Integrated microdevice for DNA restiction fragment analysis," Anal. Chem., 68 , pp. 720-723, 1996.
    • (1996) Anal. Chem , vol.68 , pp. 720-723
    • Jacobson, S.C.1    Ramsey, J.M.2
  • 6
    • 0029692711 scopus 로고    scopus 로고
    • Microchip electrophoretic immunoassay for serum cortisol
    • L.B. Koutny, D. Schmalzing, T.A. Taylor, M. Fuchs, "Microchip electrophoretic immunoassay for serum cortisol," Anal. Chem. , 68, pp. 18-22, 1996.
    • (1996) Anal. Chem , vol.68 , pp. 18-22
    • Koutny, L.B.1    Schmalzing, D.2    Taylor, T.A.3    Fuchs, M.4
  • 7
    • 0027987997 scopus 로고
    • Ultra-high-speed DNA fragment separations using microfabricated capillary array electrophoresis chips
    • A.T. Woolley and R.A. Matthies, "Ultra-high-speed DNA fragment separations using microfabricated capillary array electrophoresis chips," Proc. Natl. Acad. Sci. USA, 91, pp. 11348-11352, 1994.
    • (1994) Proc. Natl. Acad. Sci. USA , vol.91 , pp. 11348-11352
    • Woolley, A.T.1    Matthies, R.A.2
  • 8
    • 0029645606 scopus 로고
    • Ultra-high-speed DNA sequencing using capillary electrophoresis chips
    • A.T. Woolley and R.A. Matthies, "Ultra-high-speed DNA sequencing using capillary electrophoresis chips," Anal. Chem., 67 , pp. 3676-3680, 1995.
    • (1995) Anal. Chem , vol.67 , pp. 3676-3680
    • Woolley, A.T.1    Matthies, R.A.2
  • 9
    • 0001725611 scopus 로고
    • Precolumn reactions with electrophoretic analysis integrated on a microchip
    • S.C. Jacobson, R. Hergenröder, A. W. Moore, Jr., J.M. Ramsey, "Precolumn reactions with electrophoretic analysis integrated on a microchip," Anal. Chem., 66 , pp. 4127-4123, 1994.
    • (1994) Anal. Chem , vol.66 , pp. 4127-4123
    • Jacobson, S.C.1    Hergenröder, R.2    Moore Jr., A.W.3    Ramsey, J.M.4
  • 10
    • 0028818714 scopus 로고
    • Microfabricated chemical measurement systems
    • J. M. Ramsey, S. C. Jacobson, M.R. Knapp, "Microfabricated chemical measurement systems," Nature Med., 1 (10), pp. 1093-1096, 1995.
    • (1995) Nature Med , vol.1 , Issue.10 , pp. 1093-1096
    • Ramsey, J.M.1    Jacobson, S.C.2    Knapp, M.R.3
  • 11
    • 46549101119 scopus 로고
    • High-performance electrophoresis: Elimination of electroendoosmosis and solute adsorption
    • S. Hjerten, "High-performance electrophoresis: elimination of electroendoosmosis and solute adsorption," J.Chromatogr., 347, pp. 191-198, 1985.
    • (1985) J.Chromatogr , vol.347 , pp. 191-198
    • Hjerten, S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.