메뉴 건너뛰기




Volumn 7, Issue SUPPL. 2, 1997, Pages

Single and dual energy X-ray absorptiometry

Author keywords

[No Author keywords available]

Indexed keywords

BONE; BONE DENSITY; HUMAN; OSTEOPOROSIS; PHOTON ABSORPTIOMETRY; RADIODENSITOMETRY; RADIOGRAPHY; REVIEW; SCINTISCANNING;

EID: 0002992965     PISSN: 09387994     EISSN: None     Source Type: Journal    
DOI: 10.1007/pl00006861     Document Type: Article
Times cited : (61)

References (143)
  • 1
    • 0342794982 scopus 로고
    • Quantitative measurements in osteoporosis
    • Tovey FI, Stamp TCB (eds) Parthenon Publishing Group, London
    • Adams JE (1995) Quantitative measurements in osteoporosis. In: Tovey FI, Stamp TCB (eds) Measurement in metabolic bone disease. Parthenon Publishing Group, London, pp 107-142
    • (1995) Measurement in Metabolic Bone Disease , pp. 107-142
    • Adams, J.E.1
  • 2
    • 0019858976 scopus 로고
    • Factors associated with falls in the elderly: A community study
    • Prudham G, Evans JG (1981) Factors associated with falls in the elderly: a community study. Age Ageing 10:141-146
    • (1981) Age Ageing , vol.10 , pp. 141-146
    • Prudham, G.1    Evans, J.G.2
  • 3
    • 0023097051 scopus 로고
    • Risk factors for hip fractures
    • Kelsey JL, Hoffmann S (1987) Risk factors for hip fractures. N Engl J Med 316: 404-406
    • (1987) N Engl J Med , vol.316 , pp. 404-406
    • Kelsey, J.L.1    Hoffmann, S.2
  • 4
    • 0001845119 scopus 로고
    • Epidemiology of fractures
    • Riggs BL, Melton LJ (eds) Raven Press, New York
    • Melton LJ (1988) Epidemiology of fractures. In: Riggs BL, Melton LJ (eds) Osteoporosis: aetiology, diagnosis and management. Raven Press, New York, pp 111-131
    • (1988) Osteoporosis: Aetiology, Diagnosis and Management , pp. 111-131
    • Melton, L.J.1
  • 5
    • 0024458249 scopus 로고
    • Baseline measurement of bone mass predicts fracture in white women
    • Hui SL, Slemenda W, Johnston CC (1989) Baseline measurement of bone mass predicts fracture in white women. Ann Intern Med 111: 355-361
    • (1989) Ann Intern Med , vol.111 , pp. 355-361
    • Hui, S.L.1    Slemenda, W.2    Johnston, C.C.3
  • 6
    • 0025056938 scopus 로고
    • A critical review of bone mass and the risk of fractures in osteoporosis
    • Ross PD, Davis JW, Vogel JM, Wasnich RD (1990) A critical review of bone mass and the risk of fractures in osteoporosis. Calcif Tissue Int 46: 149-161
    • (1990) Calcif Tissue Int , vol.46 , pp. 149-161
    • Ross, P.D.1    Davis, J.W.2    Vogel, J.M.3    Wasnich, R.D.4
  • 7
    • 0022374775 scopus 로고
    • Prediction of postmenopausal fracture risk with use of bone mineral measurements
    • Wasnich RD, Ross PD, Heilbrun LK, Vogel JM (1985) Prediction of postmenopausal fracture risk with use of bone mineral measurements. Am J Obstet Gynecol 153: 745-751
    • (1985) Am J Obstet Gynecol , vol.153 , pp. 745-751
    • Wasnich, R.D.1    Ross, P.D.2    Heilbrun, L.K.3    Vogel, J.M.4
  • 8
    • 0014073728 scopus 로고
    • An assessment of radiological criteria used in the study of spinal osteoporosis
    • Doyle FH, Gutteridge DH, Joplin OF, Fraser R (1967) An assessment of radiological criteria used in the study of spinal osteoporosis. Br J Radiol 40: 241-250
    • (1967) Br J Radiol , vol.40 , pp. 241-250
    • Doyle, F.H.1    Gutteridge, D.H.2    Joplin, O.F.3    Fraser, R.4
  • 11
    • 0027067771 scopus 로고
    • Osteoporosis and bone mineral densitometry
    • Adams JE (1992) Osteoporosis and bone mineral densitometry. Curr Opin Radiol 4: 11-19
    • (1992) Curr Opin Radiol , vol.4 , pp. 11-19
    • Adams, J.E.1
  • 12
    • 0026344488 scopus 로고
    • Non invasive measurements of bone mass, structure and strength: Current methods and experimental techniques
    • Faulkner KG, Gluer CC, Majumdar S, Lang P, Engelke K, Genant HK (1991) Non invasive measurements of bone mass, structure and strength: current methods and experimental techniques. Am J Radiol 157: 1229-1237
    • (1991) Am J Radiol , vol.157 , pp. 1229-1237
    • Faulkner, K.G.1    Gluer, C.C.2    Majumdar, S.3    Lang, P.4    Engelke, K.5    Genant, H.K.6
  • 14
    • 0009965652 scopus 로고    scopus 로고
    • Quantitative assessment of osteoporosis: Current and future trends
    • Sartoris DJ (ed) Marcel Dekker, New York
    • Grampp S, Jergas M, Lang P, Genant HK, Gluer CC (1996) Quantitative assessment of osteoporosis: current and future trends. In: Sartoris DJ (ed) Osteoporosis: diagnosis and treatment. Marcel Dekker, New York, pp232-265
    • (1996) Osteoporosis: Diagnosis and Treatment , pp. 232-265
    • Grampp, S.1    Jergas, M.2    Lang, P.3    Genant, H.K.4    Gluer, C.C.5
  • 15
    • 0001726827 scopus 로고
    • Measurement of bone mineral in vivo: An improved method
    • Cameron JR, Sorenson J (1963) Measurement of bone mineral in vivo: an improved method. Science 142: 230-232
    • (1963) Science , vol.142 , pp. 230-232
    • Cameron, J.R.1    Sorenson, J.2
  • 16
    • 0026331482 scopus 로고
    • Methods for measuring bone mass
    • Whitehouse RW (1991) Methods for measuring bone mass. Curr Imaging 3: 213-220
    • (1991) Curr Imaging , vol.3 , pp. 213-220
    • Whitehouse, R.W.1
  • 17
    • 0014290743 scopus 로고
    • Precision and accuracy of bone mineral determination by direct photo absorptiometry
    • Cameron JR, Mazess RB, Sorensori JA (1968) Precision and accuracy of bone mineral determination by direct photo absorptiometry. Invest Radiol 3: 141-150
    • (1968) Invest Radiol , vol.3 , pp. 141-150
    • Cameron, J.R.1    Mazess, R.B.2    Sorensori, J.A.3
  • 18
  • 19
    • 0024477262 scopus 로고
    • Ultradistal and cortical forearm bone density in assessment of postmenopausal bone loss and non-axial fracture risk
    • Price RI, Barnes MP, Gutteridge DH, Baron-Hay M (1989) Ultradistal and cortical forearm bone density in assessment of postmenopausal bone loss and non-axial fracture risk. J Bone Miner Res 4: 149-154
    • (1989) J Bone Miner Res , vol.4 , pp. 149-154
    • Price, R.I.1    Barnes, M.P.2    Gutteridge, D.H.3    Baron-Hay, M.4
  • 20
    • 0014290743 scopus 로고
    • Precision and accuracy of bone mineral determination by direct photon absorptiometry
    • Cameron JR, Mazess RB, Sorenson JA (1968) Precision and accuracy of bone mineral determination by direct photon absorptiometry. Invest Radiol 3: 141-150
    • (1968) Invest Radiol , vol.3 , pp. 141-150
    • Cameron, J.R.1    Mazess, R.B.2    Sorenson, J.A.3
  • 21
    • 0022250655 scopus 로고
    • Comparison of single and dual-photon absorptiometry in post menopausal bone mineral loss
    • Nilas L, Borg J, Gotfredsen A, Christiansen C (1985) Comparison of single and dual-photon absorptiometry in post menopausal bone mineral loss. J Nucl Med 26: 1257-1262
    • (1985) J Nucl Med , vol.26 , pp. 1257-1262
    • Nilas, L.1    Borg, J.2    Gotfredsen, A.3    Christiansen, C.4
  • 22
    • 0025060311 scopus 로고
    • Appendicular bone density and age predict hip fracture in women
    • Cummings SR, Black DM, Nevitt MC (1990) Appendicular bone density and age predict hip fracture in women. J Am Med Ass 263: 665-668
    • (1990) J Am Med Ass , vol.263 , pp. 665-668
    • Cummings, S.R.1    Black, D.M.2    Nevitt, M.C.3
  • 24
    • 0018950934 scopus 로고
    • Measurement of bone mineral content in human vertebrae and hip by dual photon absorptiometry
    • Dunn WL, Wahner HW, Riggs BL (1980) Measurement of bone mineral content in human vertebrae and hip by dual photon absorptiometry. Radiology 136: 485-487
    • (1980) Radiology , vol.136 , pp. 485-487
    • Dunn, W.L.1    Wahner, H.W.2    Riggs, B.L.3
  • 25
    • 0019163550 scopus 로고
    • Measurement of bone mineral content (BMC) of the lumbar spine. Theory and application of a new two-dimensional dual photon attenuation method
    • Krolner B, Neilson SP (1980) Measurement of bone mineral content (BMC) of the lumbar spine. Theory and application of a new two-dimensional dual photon attenuation method. Scand J Clin Lab Invest 40: 653-663
    • (1980) Scand J Clin Lab Invest , vol.40 , pp. 653-663
    • Krolner, B.1    Neilson, S.P.2
  • 26
    • 0019868386 scopus 로고
    • Total body bone mineral and lean body mass by dual-photon absorptiometry
    • Peppler WW, Mazess RB (1981) Total body bone mineral and lean body mass by dual-photon absorptiometry. Calcif Tissue Int 33: 353-359
    • (1981) Calcif Tissue Int , vol.33 , pp. 353-359
    • Peppler, W.W.1    Mazess, R.B.2
  • 27
    • 0021805977 scopus 로고
    • Dual photon (Gd-153) absorptiometry of bone
    • Wahner HW, Dunn WL, Mazess RB (1985) Dual photon (Gd-153) absorptiometry of bone. Radiology 156: 203-206
    • (1985) Radiology , vol.156 , pp. 203-206
    • Wahner, H.W.1    Dunn, W.L.2    Mazess, R.B.3
  • 28
    • 0024578459 scopus 로고
    • Dual-energy radiographic absorptiometry for bone densitometry
    • Sartoris DJ, Resnick D (1989) Dual-energy radiographic absorptiometry for bone densitometry. Am J Radiol 152: 241-246
    • (1989) Am J Radiol , vol.152 , pp. 241-246
    • Sartoris, D.J.1    Resnick, D.2
  • 30
    • 0025954621 scopus 로고
    • Comparison of dual photon and dual-energy X-ray bone densitometers in a clinic setting
    • Nelson DA, Bown EB, Flynn MJ, Cody DD, Shaffer S (1991) Comparison of dual photon and dual-energy X-ray bone densitometers in a clinic setting. Skeletal Radiol 20: 591-595
    • (1991) Skeletal Radiol , vol.20 , pp. 591-595
    • Nelson, D.A.1    Bown, E.B.2    Flynn, M.J.3    Cody, D.D.4    Shaffer, S.5
  • 31
    • 0023765128 scopus 로고
    • Quantitative digital radiography versus dual photon absorptiometry of the lumbar spine
    • Kelly TL, Slovik DM, Schoenfeld DA, Neer RM (1988) Quantitative digital radiography versus dual photon absorptiometry of the lumbar spine. J Clin Endocrinol Metab 67: 839-844
    • (1988) J Clin Endocrinol Metab , vol.67 , pp. 839-844
    • Kelly, T.L.1    Slovik, D.M.2    Schoenfeld, D.A.3    Neer, R.M.4
  • 32
    • 0024336819 scopus 로고
    • X-ray dual-photon absorptiometry: A new method for measurement of bone density
    • Cullum ID, Ell PJ, Ryder JP (1989) X-ray dual-photon absorptiometry: a new method for measurement of bone density. Br J Radiol 62: 587-592
    • (1989) Br J Radiol , vol.62 , pp. 587-592
    • Cullum, I.D.1    Ell, P.J.2    Ryder, J.P.3
  • 33
    • 0001534207 scopus 로고
    • Measurement of bone density with dual-energy X-ray absorptiometry (DEXA)
    • Kellie SE (1992) Measurement of bone density with dual-energy X-ray absorptiometry (DEXA) J Am Med Assoc 267: 286-294
    • (1992) J Am Med Assoc , vol.267 , pp. 286-294
    • Kellie, S.E.1
  • 35
    • 0025977294 scopus 로고
    • The effect of positioning on dual-energy X-ray absorptiometry of the proximal femur
    • Wilson CR, Fogelman I, Blake GM, Rodin A (1991) The effect of positioning on dual-energy X-ray absorptiometry of the proximal femur. Bone Miner 13: 69-76
    • (1991) Bone Miner , vol.13 , pp. 69-76
    • Wilson, C.R.1    Fogelman, I.2    Blake, G.M.3    Rodin, A.4
  • 36
    • 0028863493 scopus 로고
    • Effect of femoral rotation on bone mineral density measurements with dual energy X-ray absorptiometry
    • Goh JC, Low SL, Bose K (1995) Effect of femoral rotation on bone mineral density measurements with dual energy X-ray absorptiometry. Calcif Tissue Int 57: 340-343
    • (1995) Calcif Tissue Int , vol.57 , pp. 340-343
    • Goh, J.C.1    Low, S.L.2    Bose, K.3
  • 37
    • 0024212997 scopus 로고
    • Measurement of bone by dual-photon absorptiometry (DPA) and dual-energy X-ray absorptiometry (DEXA)
    • Mazess RB, Barden HS (1988) Measurement of bone by dual-photon absorptiometry (DPA) and dual-energy X-ray absorptiometry (DEXA) Ann Chir Gynaecol 77: 197-203
    • (1988) Ann Chir Gynaecol , vol.77 , pp. 197-203
    • Mazess, R.B.1    Barden, H.S.2
  • 38
    • 0025107766 scopus 로고
    • Comparative study of the performance of X-ray and gadolinium 153 bone densitometers at the level of the spine, femoral neck and femoral shaft
    • Slosman DO, Rizzoli R, Buchs B, Piana F, Donath A, Bonjour JP (1990) Comparative study of the performance of X-ray and gadolinium 153 bone densitometers at the level of the spine, femoral neck and femoral shaft. Eur J Nucl Med 17: 3-9
    • (1990) Eur J Nucl Med , vol.17 , pp. 3-9
    • Slosman, D.O.1    Rizzoli, R.2    Buchs, B.3    Piana, F.4    Donath, A.5    Bonjour, J.P.6
  • 39
    • 0026082108 scopus 로고
    • The interchangeability of radioisotope and X-ray based measurements of bone density
    • Adachi JD, Webber CE (1991) The interchangeability of radioisotope and X-ray based measurements of bone density. Br J Radiol 64: 217-220
    • (1991) Br J Radiol , vol.64 , pp. 217-220
    • Adachi, J.D.1    Webber, C.E.2
  • 40
    • 0026604152 scopus 로고
    • An evaluation of dual-energy X-ray absorptiometry and comparison with dual-photon absorptiometry
    • Lees B, Stevenson JC (1992) An evaluation of dual-energy X-ray absorptiometry and comparison with dual-photon absorptiometry. Osteoporos Int 2: 146-152
    • (1992) Osteoporos Int , vol.2 , pp. 146-152
    • Lees, B.1    Stevenson, J.C.2
  • 41
    • 0025358771 scopus 로고
    • Accuracy of dual-energy radiographic absorptiometry of the lumbar spine: Cadaver study
    • Ho CP, Kim RW, Schaffler MB, Sartoris DJ (1990) Accuracy of dual-energy radiographic absorptiometry of the lumbar spine: cadaver study. Radiology 176: 171-173
    • (1990) Radiology , vol.176 , pp. 171-173
    • Ho, C.P.1    Kim, R.W.2    Schaffler, M.B.3    Sartoris, D.J.4
  • 42
    • 0027415863 scopus 로고
    • Accuracy of dual-energy X-ray absorptiometry for the determination of bone mineral content in the thoracic and lumbar spine: An in-vitro study
    • Edmondston SJ, Singer KP, Price RL, Breidahl PD (1993) Accuracy of dual-energy X-ray absorptiometry for the determination of bone mineral content in the thoracic and lumbar spine: an in-vitro study. Br J Radiol 66: 309-313
    • (1993) Br J Radiol , vol.66 , pp. 309-313
    • Edmondston, S.J.1    Singer, K.P.2    Price, R.L.3    Breidahl, P.D.4
  • 43
    • 0027205520 scopus 로고
    • Precision and accuracy of rat whole body and femur bone mineral determination with dual X-ray absorptiometry
    • Hagiwara S, Lane N, Engelke K, Sebastian A, Kimmel DB, Genant HK (1993) Precision and accuracy of rat whole body and femur bone mineral determination with dual X-ray absorptiometry. Bone Miner 22: 57-68
    • (1993) Bone Miner , vol.22 , pp. 57-68
    • Hagiwara, S.1    Lane, N.2    Engelke, K.3    Sebastian, A.4    Kimmel, D.B.5    Genant, H.K.6
  • 44
    • 0026168286 scopus 로고
    • In vivo and in vitro precision of bone density measured by dual energy X-ray absorptiometry
    • Lilley J, Walters BC, Heath DA, Drotc Z (1991) In vivo and in vitro precision of bone density measured by dual energy X-ray absorptiometry. Osteoporos Int 1: 141-146
    • (1991) Osteoporos Int , vol.1 , pp. 141-146
    • Lilley, J.1    Walters, B.C.2    Heath, D.A.3    Drotc, Z.4
  • 45
    • 0026034394 scopus 로고
    • Longitudinal precision of dual-energy X-ray absorptiometry in a multicentre study
    • Orwell ES, Eviatt SK (1991) Longitudinal precision of dual-energy X-ray absorptiometry in a multicentre study. J Bone Miner Res 6: 191-197
    • (1991) J Bone Miner Res , vol.6 , pp. 191-197
    • Orwell, E.S.1    Eviatt, S.K.2
  • 46
    • 0025950822 scopus 로고
    • Precision and sensitivity of dual-energy X-ray absorptiometry in spinal osteoporosis
    • Pouilles JM, Tremollieres F, Todorovsky N, Ribot C (1991) Precision and sensitivity of dual-energy X-ray absorptiometry in spinal osteoporosis. J Bone Miner Res 6: 997-1002
    • (1991) J Bone Miner Res , vol.6 , pp. 997-1002
    • Pouilles, J.M.1    Tremollieres, F.2    Todorovsky, N.3    Ribot, C.4
  • 48
    • 0026736215 scopus 로고
    • Precision of dual-energy X-ray absorptiometry in determining bone mineral density and content of various skeletal sites
    • Sievänen H, Oja P, Vuori I (1992) Precision of dual-energy X-ray absorptiometry in determining bone mineral density and content of various skeletal sites. J Nucl Med 33: 1137-1142
    • (1992) J Nucl Med , vol.33 , pp. 1137-1142
    • Sievänen, H.1    Oja, P.2    Vuori, I.3
  • 49
    • 0027518805 scopus 로고
    • Precision of dual-energy X-ray absorptiometry in the upper extremities
    • Sievänen H, Kannus P, Oja P, Vuori I (1993) Precision of dual-energy X-ray absorptiometry in the upper extremities. J Bone Miner Res 20: 235-243
    • (1993) J Bone Miner Res , vol.20 , pp. 235-243
    • Sievänen, H.1    Kannus, P.2    Oja, P.3    Vuori, I.4
  • 52
    • 0026047329 scopus 로고
    • An evaluation of forearm bone mineral measurement with dual-energy X-ray absorptiometry
    • Larcos G, Wahner HW (1991) An evaluation of forearm bone mineral measurement with dual-energy X-ray absorptiometry. J Nucl Med 32: 2101-2106
    • (1991) J Nucl Med , vol.32 , pp. 2101-2106
    • Larcos, G.1    Wahner, H.W.2
  • 53
    • 0026581838 scopus 로고
    • Measurement of forearm BMD in normal women by dual-energy X-ray absorptiometry
    • Ryan PJ, Blake GM, Fogelman I (1992) Measurement of forearm BMD in normal women by dual-energy X-ray absorptiometry. Br J Radiol 65: 127-131
    • (1992) Br J Radiol , vol.65 , pp. 127-131
    • Ryan, P.J.1    Blake, G.M.2    Fogelman, I.3
  • 54
    • 0025787190 scopus 로고
    • Validation of body composition by dual-energy X-ray absorptiometry (DEXA)
    • Haarbo J, Gotfredsen A, Hassager C, Christiansen C (1991) Validation of body composition by dual-energy X-ray absorptiometry (DEXA) Clin Physiol 11: 331-341
    • (1991) Clin Physiol , vol.11 , pp. 331-341
    • Haarbo, J.1    Gotfredsen, A.2    Hassager, C.3    Christiansen, C.4
  • 56
    • 0026552865 scopus 로고
    • Assessment of the composition of major body regions by dual energy X-ray absorptiometry (DEXA) with special reference to limb muscle mass
    • Fuller NJ, Laskey MA, Elia M (1992) Assessment of the composition of major body regions by dual energy X-ray absorptiometry (DEXA) with special reference to limb muscle mass. Clin Physiol 12: 253-266
    • (1992) Clin Physiol , vol.12 , pp. 253-266
    • Fuller, N.J.1    Laskey, M.A.2    Elia, M.3
  • 57
    • 0027466859 scopus 로고
    • Total body studies in normal British women using dual-energy X-ray absorptiometry
    • Herd RJM, Blake GM, Parker JC, Ryan PJ, Fogelman I (1993) Total body studies in normal British women using dual-energy X-ray absorptiometry. Br J Radiol 66: 303-308
    • (1993) Br J Radiol , vol.66 , pp. 303-308
    • Herd, R.J.M.1    Blake, G.M.2    Parker, J.C.3    Ryan, P.J.4    Fogelman, I.5
  • 58
    • 0029382221 scopus 로고
    • Body composition by DXA: Tried and true?
    • Kohrt WM (1995) Body composition by DXA: tried and true? Med Sci Sports Exerc 27: 1349-1354
    • (1995) Med Sci Sports Exerc , vol.27 , pp. 1349-1354
    • Kohrt, W.M.1
  • 59
    • 0025900350 scopus 로고
    • Comparison of total body measurements by dual-energy X-ray absorptiometry and dual-photon absorptiometry
    • Nuti R, Martini G, Righe G, Frediani B, Turchetti V (1991) Comparison of total body measurements by dual-energy X-ray absorptiometry and dual-photon absorptiometry. J Bone Miner Res 6: 681-687
    • (1991) J Bone Miner Res , vol.6 , pp. 681-687
    • Nuti, R.1    Martini, G.2    Righe, G.3    Frediani, B.4    Turchetti, V.5
  • 61
    • 0027287990 scopus 로고
    • Dual-energy X-ray absorptiometry of the rat: Accuracy, precision and measurement of bone loss
    • Griffin MC, Kimble R, Hopfer W, Pacifia R (1993) Dual-energy X-ray absorptiometry of the rat: accuracy, precision and measurement of bone loss. J Bone Miner Res 8: 795-800
    • (1993) J Bone Miner Res , vol.8 , pp. 795-800
    • Griffin, M.C.1    Kimble, R.2    Hopfer, W.3    Pacifia, R.4
  • 62
    • 0029029287 scopus 로고
    • Specific evaluation of localized bone mass and bone loss in the rat using dual-energy X-ray absorptiometry subregional analysis
    • Pastoureau P, Chomel A, Bonnet J (1995) Specific evaluation of localized bone mass and bone loss in the rat using dual-energy X-ray absorptiometry subregional analysis. Osteoporos Int 5: 143-149
    • (1995) Osteoporos Int , vol.5 , pp. 143-149
    • Pastoureau, P.1    Chomel, A.2    Bonnet, J.3
  • 63
    • 0028935916 scopus 로고
    • Dual-energy X-ray absorptiometry of the calcaneus: Comparison with vertebral X-ray absorptiometry and quantitative computed tomography
    • Laval-Jeantet AM, Bergot C, Williams M, Davidson K, Laval-Jeantet M (1995) Dual-energy X-ray absorptiometry of the calcaneus: comparison with vertebral X-ray absorptiometry and quantitative computed tomography. Calcif Tissue Int 56: 14-18
    • (1995) Calcif Tissue Int , vol.56 , pp. 14-18
    • Laval-Jeantet, A.M.1    Bergot, C.2    Williams, M.3    Davidson, K.4    Laval-Jeantet, M.5
  • 65
    • 0028222513 scopus 로고
    • Automated evaluation of hip axis length of predicting hip fracture
    • Faulkner KT, McClung M, Cummings SE (1994) Automated evaluation of hip axis length of predicting hip fracture. J Bone Miner Res 9: 1065-1070
    • (1994) J Bone Miner Res , vol.9 , pp. 1065-1070
    • Faulkner, K.T.1    McClung, M.2    Cummings, S.E.3
  • 66
    • 0027976849 scopus 로고
    • Dual-energy X-ray absorptiometry is also an accurate and precise method to measure the dimensions of human long bones
    • Sieranen H, Kannus P, Oja P, Vuori I (1994) Dual-energy X-ray absorptiometry is also an accurate and precise method to measure the dimensions of human long bones. Calcif Tissue Int 54: 101-105
    • (1994) Calcif Tissue Int , vol.54 , pp. 101-105
    • Sieranen, H.1    Kannus, P.2    Oja, P.3    Vuori, I.4
  • 67
    • 0028876258 scopus 로고
    • Recent developments in DXA quality of new DXA/MXA devices for densitometry and morphometry
    • Felsenberg D, Gowin W, Diessel E, Armburst S, Mews J (1995) Recent developments in DXA quality of new DXA/MXA devices for densitometry and morphometry. Eur J Radiol 20: 179-184
    • (1995) Eur J Radiol , vol.20 , pp. 179-184
    • Felsenberg, D.1    Gowin, W.2    Diessel, E.3    Armburst, S.4    Mews, J.5
  • 68
    • 0025317879 scopus 로고
    • Measurement of bone mineral content of the lumbar spine by dual-energy X-ray absorptiometry in normal children: Correlations with growth parameters
    • Glastre C, Braillon P, David L, Cochat P, Meunier PJ, Delmas PD (1990) Measurement of bone mineral content of the lumbar spine by dual-energy X-ray absorptiometry in normal children: correlations with growth parameters. J Clin Endocrnol Metab 70: 1330-1333
    • (1990) J Clin Endocrnol Metab , vol.70 , pp. 1330-1333
    • Glastre, C.1    Braillon, P.2    David, L.3    Cochat, P.4    Meunier, P.J.5    Delmas, P.D.6
  • 69
    • 0026071838 scopus 로고
    • Normative data for lumbar spine bone mineral content in children: Influence of age, height, weight and pubertal state
    • De Schepper J, Derde MP, Van den Broeck M, Piepsz A, Jonckheer MH (1991) Normative data for lumbar spine bone mineral content in children: influence of age, height, weight and pubertal state. J Nucl Med 32: 216-220
    • (1991) J Nucl Med , vol.32 , pp. 216-220
    • De Schepper, J.1    Derde, M.P.2    Van den Broeck, M.3    Piepsz, A.4    Jonckheer, M.H.5
  • 70
    • 0025940870 scopus 로고
    • Bone density in adolescents
    • Ott SM (1991) Bone density in adolescents. N Engl J Med 23: 1646-1647
    • (1991) N Engl J Med , vol.23 , pp. 1646-1647
    • Ott, S.M.1
  • 72
    • 0026717266 scopus 로고
    • Dual-energy X-ray absorptiometry measurement of bone mineral content in new-borns: Validation of the technique
    • Braillon PM, Salle BL, Brunet J (1992) Dual-energy X-ray absorptiometry measurement of bone mineral content in new-borns: validation of the technique. Paediatr Res 32: 77-80
    • (1992) Paediatr Res , vol.32 , pp. 77-80
    • Braillon, P.M.1    Salle, B.L.2    Brunet, J.3
  • 73
    • 0027069482 scopus 로고
    • Lumbar bone mineral content measured by dual-energy X-ray absorptiometry in newborns and infants
    • Salle BL, Braillon P, Glorieux FH (1992) Lumbar bone mineral content measured by dual-energy X-ray absorptiometry in newborns and infants. Acta Paediatr 81: 953-958
    • (1992) Acta Paediatr , vol.81 , pp. 953-958
    • Salle, B.L.1    Braillon, P.2    Glorieux, F.H.3
  • 75
    • 0029007703 scopus 로고
    • Validation of accuracy and precision of dual-energy X-ray absorptiometry for infants
    • Koo WW, Massom LR, Walters J (1995) Validation of accuracy and precision of dual-energy X-ray absorptiometry for infants. J Bone Miner Res 10: 1111-1115
    • (1995) J Bone Miner Res , vol.10 , pp. 1111-1115
    • Koo, W.W.1    Massom, L.R.2    Walters, J.3
  • 76
    • 0030066046 scopus 로고    scopus 로고
    • Evaluation of dual-energy X-ray absorptiometry for body composition assessment in piglets and term human neonates
    • Picaud JC, Rigo J, Nyamugato K, Milet J, Senterre J (1996) Evaluation of dual-energy X-ray absorptiometry for body composition assessment in piglets and term human neonates. Am J Clin Nutr 63: 157-163
    • (1996) Am J Clin Nutr , vol.63 , pp. 157-163
    • Picaud, J.C.1    Rigo, J.2    Nyamugato, K.3    Milet, J.4    Senterre, J.5
  • 78
    • 0026093033 scopus 로고
    • Effect of aortic sclerosis on bone mineral measurements by dual-photon absorptiometry
    • Frohn J, Wilken T, Falk S, Stutte HJ, Kollath J, Hor G (1991) Effect of aortic sclerosis on bone mineral measurements by dual-photon absorptiometry. J Nucl Med 32: 259-262
    • (1991) J Nucl Med , vol.32 , pp. 259-262
    • Frohn, J.1    Wilken, T.2    Falk, S.3    Stutte, H.J.4    Kollath, J.5    Hor, G.6
  • 79
    • 0028956926 scopus 로고
    • Evaluation of dual-energy X-ray absorptiometry bone mineral measurement - Comparison of a single-beam and fan-beam design: The effect of osteophytic calcification on spine bone mineral density
    • Franck H, Munz M, Secherrer M (1995) Evaluation of dual-energy X-ray absorptiometry bone mineral measurement - comparison of a single-beam and fan-beam design: the effect of osteophytic calcification on spine bone mineral density. Calcif Tissue Int 56: 192-195
    • (1995) Calcif Tissue Int , vol.56 , pp. 192-195
    • Franck, H.1    Munz, M.2    Secherrer, M.3
  • 80
    • 0025341080 scopus 로고
    • Lateral dual-energy radiography: A new method for measuring vertebral bone density: a preliminary study
    • Rupich R, Pacifici R, Griffin M, Vered I, Susman N, Avioli LV (1990) Lateral dual-energy radiography: a new method for measuring vertebral bone density: a preliminary study. J Clin Endocrinol Metab 70: 1768-1770
    • (1990) J Clin Endocrinol Metab , vol.70 , pp. 1768-1770
    • Rupich, R.1    Pacifici, R.2    Griffin, M.3    Vered, I.4    Susman, N.5    Avioli, L.V.6
  • 81
    • 0025495344 scopus 로고
    • Vertebral bone mineral density measured laterally by dual-energy X-ray absorptiometry
    • Slosman DO, Rizzoli R, Donath A, Bonjour J-Ph (1990) Vertebral bone mineral density measured laterally by dual-energy X-ray absorptiometry. Osteoporos Int 1: 23-29
    • (1990) Osteoporos Int , vol.1 , pp. 23-29
    • Slosman, D.O.1    Rizzoli, R.2    Donath, A.3    Bonjour, J.-P.4
  • 82
    • 0025312435 scopus 로고
    • Lateral dual-photon absorptiometry: A new technique to measure bone mineral density at the lumbar spine
    • Uebelhart D, Duboeuf F, Meunier PJ, Delmas PD (1990) Lateral dual-photon absorptiometry: a new technique to measure bone mineral density at the lumbar spine. J Bone Miner Res 5: 525-531
    • (1990) J Bone Miner Res , vol.5 , pp. 525-531
    • Uebelhart, D.1    Duboeuf, F.2    Meunier, P.J.3    Delmas, P.D.4
  • 84
    • 0028343129 scopus 로고
    • Dual-energy X-ray absorptiometry of the lumbar spine: The precision of paired anteroposterior/lateral studies
    • Blake GM, Jagathesan T, Herd RJ, Fogelman I (1994) Dual-energy X-ray absorptiometry of the lumbar spine: the precision of paired anteroposterior/lateral studies. Br J Radiol 67: 624-630
    • (1994) Br J Radiol , vol.67 , pp. 624-630
    • Blake, G.M.1    Jagathesan, T.2    Herd, R.J.3    Fogelman, I.4
  • 85
    • 0029059588 scopus 로고
    • Anteroposterior versus lateral bone mineral density of spine assessed by dual X-ray absorptiometry
    • Del Rio L, Pons F, Huguet M, Setoain FJ, Setoain J (1995) Anteroposterior versus lateral bone mineral density of spine assessed by dual X-ray absorptiometry. Eur J Nucl Med 22: 407-112
    • (1995) Eur J Nucl Med , vol.22 , pp. 407-1112
    • Del Rio, L.1    Pons, F.2    Huguet, M.3    Setoain, F.J.4    Setoain, J.5
  • 88
    • 0028049747 scopus 로고
    • Osteoporosis: Diagnosis with lateral and posteroanterior dual X-ray absorptiometry compared with quantitative CT
    • Guglielmi G, Grimston SK, Fischer KC, Pacifici R (1994) Osteoporosis: diagnosis with lateral and posteroanterior dual X-ray absorptiometry compared with quantitative CT. Radiology 192: 845-850
    • (1994) Radiology , vol.192 , pp. 845-850
    • Guglielmi, G.1    Grimston, S.K.2    Fischer, K.C.3    Pacifici, R.4
  • 89
    • 0026466078 scopus 로고
    • Lateral spine densitometry is a more sensitive indicator of glucocorticoid-induced bone loss
    • Reid IR, Evans MC, Stapleton J (1992) Lateral spine densitometry is a more sensitive indicator of glucocorticoid-induced bone loss. J Bone Miner Res 7: 1221-1225
    • (1992) J Bone Miner Res , vol.7 , pp. 1221-1225
    • Reid, I.R.1    Evans, M.C.2    Stapleton, J.3
  • 90
    • 0029029258 scopus 로고
    • Estimates of volumetric bone density from projectional measurements improve the discriminatory capability of dual X-ray absorptiometry
    • Jergas M, Breitenseheer M, Gluer CC, Yu W, Genant HK (1995) Estimates of volumetric bone density from projectional measurements improve the discriminatory capability of dual X-ray absorptiometry. J Bone Miner Res 10: 1101-1110
    • (1995) J Bone Miner Res , vol.10 , pp. 1101-1110
    • Jergas, M.1    Breitenseheer, M.2    Gluer, C.C.3    Yu, W.4    Genant, H.K.5
  • 92
    • 0028846896 scopus 로고
    • Technical considerations of dual-energy X-ray absorptiometry-based bone mineral measurements for paediatric studies
    • Koo WW, Walters J, Bush AJ (1995) Technical considerations of dual-energy X-ray absorptiometry-based bone mineral measurements for paediatric studies. J Bone Miner Res 10: 1998-2004
    • (1995) J Bone Miner Res , vol.10 , pp. 1998-2004
    • Koo, W.W.1    Walters, J.2    Bush, A.J.3
  • 93
    • 0030007089 scopus 로고
    • Assessment of changes in dual-energy X-ray absorptiometry performance following a system upgrade
    • Simmons A, Barrington SF, Archbold LJ, O'Doherty MJ, Coakley AJ (1995) Assessment of changes in dual-energy X-ray absorptiometry performance following a system upgrade. Nucl Med Commun 17: 331-341
    • (1995) Nucl Med Commun , vol.17 , pp. 331-341
    • Simmons, A.1    Barrington, S.F.2    Archbold, L.J.3    O'Doherty, M.J.4    Coakley, A.J.5
  • 94
    • 0028791592 scopus 로고
    • Hologic QDR 2000 whole-body scans: A comparison of three combinations of scan modes and analysis software
    • Spector E, Le Blanc A, Shackelford L (1995) Hologic QDR 2000 whole-body scans: a comparison of three combinations of scan modes and analysis software. Osteoporos Int 5: 440-445
    • (1995) Osteoporos Int , vol.5 , pp. 440-445
    • Spector, E.1    Le Blanc, A.2    Shackelford, L.3
  • 95
    • 0027986512 scopus 로고
    • Comparison between Hologic, Lunar and Norland dual-energy X-ray absorptiometers and other techniques used for whole-body soft tissue measurements
    • Tothill P, Avenell A, Love J, Reid DM (1994) Comparison between Hologic, Lunar and Norland dual-energy X-ray absorptiometers and other techniques used for whole-body soft tissue measurements. Eur J Clin Nutr 48: 781-794
    • (1994) Eur J Clin Nutr , vol.48 , pp. 781-794
    • Tothill, P.1    Avenell, A.2    Love, J.3    Reid, D.M.4
  • 96
    • 0028568086 scopus 로고
    • Precision and accuracy of measurements of whole-bone mineral: Comparisons between Hologic, Lunar and Norland dual-energy X-ray absorptiometers
    • Tothill P, Avenell A, Reid DM (1994) Precision and accuracy of measurements of whole-bone mineral: comparisons between Hologic, Lunar and Norland dual-energy X-ray absorptiometers. Br J Radiol 67: 1210-1217
    • (1994) Br J Radiol , vol.67 , pp. 1210-1217
    • Tothill, P.1    Avenell, A.2    Reid, D.M.3
  • 97
    • 0029000960 scopus 로고
    • Comparisons between three dual-energy X-ray absorptiometers used for measuring spine and femur
    • Tothill P, Fenner JA, Reid DM (1995) Comparisons between three dual-energy X-ray absorptiometers used for measuring spine and femur. Br J Radiol 68: 621-629
    • (1995) Br J Radiol , vol.68 , pp. 621-629
    • Tothill, P.1    Fenner, J.A.2    Reid, D.M.3
  • 98
    • 0025780560 scopus 로고
    • Intersite comparison of the Hologic QDR-1000 dual energy X-ray densitometer
    • Blake GM, Tong CM, Fogelman I (1991) Intersite comparison of the Hologic QDR-1000 dual energy X-ray densitometer. Br J Radiol 64: 440-446
    • (1991) Br J Radiol , vol.64 , pp. 440-446
    • Blake, G.M.1    Tong, C.M.2    Fogelman, I.3
  • 100
    • 0026735628 scopus 로고
    • Comparison of single photon and dual-energy X-ray absorptiometry of the radius
    • Nelson D, Feingold M, Mascha E, Kleerkloper M (1992) Comparison of single photon and dual-energy X-ray absorptiometry of the radius. Bone Miner 18: 77-83
    • (1992) Bone Miner , vol.18 , pp. 77-83
    • Nelson, D.1    Feingold, M.2    Mascha, E.3    Kleerkloper, M.4
  • 101
    • 0028077289 scopus 로고
    • Switching from DXA pencil-beam to fan beam. I Studies in vitro at four centres
    • Elken P, Barenholdt O, Bjorn Jensen L, Gram J, Pors Nielsen S (1994) Switching from DXA pencil-beam to fan beam. I Studies in vitro at four centres. Bone 15: 667-670
    • (1994) Bone , vol.15 , pp. 667-670
    • Elken, P.1    Barenholdt, O.2    Bjorn Jensen, L.3    Gram, J.4    Pors Nielsen, S.5
  • 102
    • 0029666110 scopus 로고    scopus 로고
    • Cross-calibration of a fan-beam X-ray densitomctry with a pencil-beam system
    • Bouyoucef SE, Cullen ID, Ell PJ (1996) Cross-calibration of a fan-beam X-ray densitomctry with a pencil-beam system. Br J Radiol 69: 522-531
    • (1996) Br J Radiol , vol.69 , pp. 522-531
    • Bouyoucef, S.E.1    Cullen, I.D.2    Ell, P.J.3
  • 103
    • 0028924474 scopus 로고
    • Bilateral comparison of femoral bone density and hip axis length from single and fan beam DXA scans
    • Faulkner KG, Genant HK, McClung M (1995) Bilateral comparison of femoral bone density and hip axis length from single and fan beam DXA scans. Calcif Tissue Int 56: 26-31
    • (1995) Calcif Tissue Int , vol.56 , pp. 26-31
    • Faulkner, K.G.1    Genant, H.K.2    McClung, M.3
  • 104
    • 0028865278 scopus 로고
    • Comparison of rates of bone loss from the spine measured using two manufacturers' densitometers
    • Peel NF, Eastell R (1995) Comparison of rates of bone loss from the spine measured using two manufacturers' densitometers. J Bone Miner Res 10: 1796-1801
    • (1995) J Bone Miner Res , vol.10 , pp. 1796-1801
    • Peel, N.F.1    Eastell, R.2
  • 106
    • 0027855527 scopus 로고
    • Bone density measurements in clinical trials: The challenge of ensuring optimal data
    • Miller CG (1993) Bone density measurements in clinical trials: the challenge of ensuring optimal data. Br J Clin Res 4: 113-120
    • (1993) Br J Clin Res , vol.4 , pp. 113-120
    • Miller, C.G.1
  • 107
    • 0028364532 scopus 로고
    • Quality control of bone densitometry in a National Health Survey (NHANES III) using three mobile examination centres
    • Wahner HW, Looker A, Dunn WL, Walters LC, Hauser MF, Novak C (1994) Quality control of bone densitometry in a National Health Survey (NHANES III) using three mobile examination centres. J Bone Miner Res 9: 951-960
    • (1994) J Bone Miner Res , vol.9 , pp. 951-960
    • Wahner, H.W.1    Looker, A.2    Dunn, W.L.3    Walters, L.C.4    Hauser, M.F.5    Novak, C.6
  • 108
    • 0028991317 scopus 로고
    • Quality control of DXA instruments in multicenter trials
    • Faulkner KG, McClung MR (1995) Quality control of DXA instruments in multicenter trials. Osteoporos Int 5: 218-227
    • (1995) Osteoporos Int , vol.5 , pp. 218-227
    • Faulkner, K.G.1    McClung, M.R.2
  • 109
    • 0026749121 scopus 로고
    • Work in progress: A cross-calibration study of four DXA instruments designed to culminate in inter-manufacturer standardization
    • Nord RH (1992) Work in progress: a cross-calibration study of four DXA instruments designed to culminate in inter-manufacturer standardization. Osteoporos Int 2: 210-211
    • (1992) Osteoporos Int , vol.2 , pp. 210-211
    • Nord, R.H.1
  • 110
    • 0028051591 scopus 로고
    • Comparison of four methods for cross-calibrating dual-energy X-ray absorptiometers to eliminate systematic errors when upgrading equipment
    • Finkelstein JS, Butler JP, Cleary RL, Neer RM (1994) Comparison of four methods for cross-calibrating dual-energy X-ray absorptiometers to eliminate systematic errors when upgrading equipment. J Bone Miner Res 9: 1945-1952
    • (1994) J Bone Miner Res , vol.9 , pp. 1945-1952
    • Finkelstein, J.S.1    Butler, J.P.2    Cleary, R.L.3    Neer, R.M.4
  • 111
    • 0029123724 scopus 로고
    • Cross-calibration of QDR-2000 and QDR-1000 dual-energy X-ray densitometers for bone mineral and soft tissue measurements
    • Abrahamsen B, Gram J, Hansen TB, Beck-Nielsen H (1995) Cross-calibration of QDR-2000 and QDR-1000 dual-energy X-ray densitometers for bone mineral and soft tissue measurements. Bone 16: 385-390
    • (1995) Bone , vol.16 , pp. 385-390
    • Abrahamsen, B.1    Gram, J.2    Hansen, T.B.3    Beck-Nielsen, H.4
  • 113
    • 0029080928 scopus 로고
    • The European Spine Phantom: A tool for standardisation and quality control in spinal bone mineral measurement by DXA and QCT
    • Kalender WA, Felsenberg D, Genant HK, Dequeker J, Reeve J (1995) The European Spine Phantom: A tool for standardisation and quality control in spinal bone mineral measurement by DXA and QCT. Eur J Radiol 20: 83-92
    • (1995) Eur J Radiol , vol.20 , pp. 83-92
    • Kalender, W.A.1    Felsenberg, D.2    Genant, H.K.3    Dequeker, J.4    Reeve, J.5
  • 114
    • 0026607069 scopus 로고
    • Effective dose values in bone mineral measurements by photon absorptiometry and computed tomography
    • Kalender WA (1992) Effective dose values in bone mineral measurements by photon absorptiometry and computed tomography. Osteoporos Int 2: 82-87
    • (1992) Osteoporos Int , vol.2 , pp. 82-87
    • Kalender, W.A.1
  • 115
    • 0029884750 scopus 로고    scopus 로고
    • Patient doses in bone mineral densitometry
    • Huda W, Morin RL (1996) Patient doses in bone mineral densitometry. Br J Radiol 69: 422-425
    • (1996) Br J Radiol , vol.69 , pp. 422-425
    • Huda, W.1    Morin, R.L.2
  • 117
    • 0029875881 scopus 로고    scopus 로고
    • Radiological assessment of a new bone densitometer: The Lunar Expert
    • Njeh CF, Apple K, Temperton DH, Boivin CM (1996) Radiological assessment of a new bone densitometer: the Lunar Expert. Br J Radiol 69: 335-340
    • (1996) Br J Radiol , vol.69 , pp. 335-340
    • Njeh, C.F.1    Apple, K.2    Temperton, D.H.3    Boivin, C.M.4
  • 118
    • 0029899222 scopus 로고    scopus 로고
    • Occupational dose to the radiographer in dual X-ray absorptiometry: A comparison of pencil-beam and fan-beam systems
    • Patel R, Blake GM, Batchelor S, Fogelman I (1996) Occupational dose to the radiographer in dual X-ray absorptiometry: a comparison of pencil-beam and fan-beam systems. Br J Radiol 69: 539-543
    • (1996) Br J Radiol , vol.69 , pp. 539-543
    • Patel, R.1    Blake, G.M.2    Batchelor, S.3    Fogelman, I.4
  • 119
    • 0023552438 scopus 로고
    • Bone mineral densitometry
    • Cummings SR (1987) Bone mineral densitometry. Ann Int Med 107: 932-936
    • (1987) Ann Int Med , vol.107 , pp. 932-936
    • Cummings, S.R.1
  • 121
    • 84991113805 scopus 로고
    • Clinical indications for bone mass measurement. A report from the Scientific Advisory Board of the National Osteoporosis Foundation
    • Johnson CC, Melton LJ, Lindsay R, Eddy DM (1989) Clinical indications for bone mass measurement. A report from the Scientific Advisory Board of the National Osteoporosis Foundation. J Bone Miner Res 4 [Suppl 2]: 1-28
    • (1989) J Bone Miner Res , vol.4 , Issue.2 SUPPL. , pp. 1-28
    • Johnson, C.C.1    Melton, L.J.2    Lindsay, R.3    Eddy, D.M.4
  • 124
    • 0023908934 scopus 로고
    • Bone mass measurement: Which site to measure
    • Slemenda CW, Johnson CC (1988) Bone mass measurement: which site to measure. Am J Med 84: 643-645
    • (1988) Am J Med , vol.84 , pp. 643-645
    • Slemenda, C.W.1    Johnson, C.C.2
  • 126
    • 0023547937 scopus 로고
    • Definition of spine fracture threshold based upon prospective fracture risk
    • Ross PD, Wasnich RD, Heilbrun LK, Vogel JM (1987) Definition of spine fracture threshold based upon prospective fracture risk. Bone 8: 271-278
    • (1987) Bone , vol.8 , pp. 271-278
    • Ross, P.D.1    Wasnich, R.D.2    Heilbrun, L.K.3    Vogel, J.M.4
  • 128
    • 0026708122 scopus 로고
    • Axial and appendicular bone density predict fractures in older women
    • Black DM, Cummings SR, Genant HK (1992) Axial and appendicular bone density predict fractures in older women. J Bone Miner Res 6: 633-638
    • (1992) J Bone Miner Res , vol.6 , pp. 633-638
    • Black, D.M.1    Cummings, S.R.2    Genant, H.K.3
  • 130
    • 0027167008 scopus 로고
    • Predicting various fragility fractures in women by forearm densitometry: A follow-up study
    • Gardsell P, Johnell O, Nilsson BE, Gullberg B (1993) Predicting various fragility fractures in women by forearm densitometry: a follow-up study. Calcif Tissue Int 52: 348-353
    • (1993) Calcif Tissue Int , vol.52 , pp. 348-353
    • Gardsell, P.1    Johnell, O.2    Nilsson, B.E.3    Gullberg, B.4
  • 131
    • 0025287148 scopus 로고
    • Interpretation of bone densitometry measurements; disadvantages of a percentage scale and a discussion of some alternatives
    • Parfitt AM (1990) Interpretation of bone densitometry measurements; disadvantages of a percentage scale and a discussion of some alternatives. J Bone Miner Res 5: 537-540
    • (1990) J Bone Miner Res , vol.5 , pp. 537-540
    • Parfitt, A.M.1
  • 132
    • 0028188829 scopus 로고
    • Assessment of fracture risk and its application to screening for postmenopausal osteoporosis
    • World Health Organization, Geneva
    • World Health Organisation (1994) Assessment of fracture risk and its application to screening for postmenopausal osteoporosis. Technical report series 843, World Health Organization, Geneva
    • (1994) Technical Report Series , vol.843
  • 133
    • 0026509352 scopus 로고
    • Dual energy X-ray absorptiometry in normal women: A cross-sectional study of 717 Finnish volunteers
    • Kroger H, Heikkinen J, Laitinen K, Kotaniemi A (1992) Dual energy X-ray absorptiometry in normal women: a cross-sectional study of 717 Finnish volunteers. Osteoporos Int 2: 135-140
    • (1992) Osteoporos Int , vol.2 , pp. 135-140
    • Kroger, H.1    Heikkinen, J.2    Laitinen, K.3    Kotaniemi, A.4
  • 135
    • 0029615478 scopus 로고
    • A survey of dual-energy X-ray absorptiometry (DEXA) normal reference ranges used within the UK and their effect on classification
    • Simmons A, O'Doherty MJ, Barrington SF, Coakley AJ (1995) A survey of dual-energy X-ray absorptiometry (DEXA) normal reference ranges used within the UK and their effect on classification. Nucl Med Commun 16: 1041-1053
    • (1995) Nucl Med Commun , vol.16 , pp. 1041-1053
    • Simmons, A.1    O'Doherty, M.J.2    Barrington, S.F.3    Coakley, A.J.4
  • 136
  • 139
    • 0026012809 scopus 로고
    • The clinical application of serial bone mass measurements
    • Ross PD, Davis JW, Wasnick RD, Vogel JM (1991) The clinical application of serial bone mass measurements. Bone Miner 12: 189-199
    • (1991) Bone Miner , vol.12 , pp. 189-199
    • Ross, P.D.1    Davis, J.W.2    Wasnick, R.D.3    Vogel, J.M.4
  • 141
    • 0029112340 scopus 로고
    • Accurate assessment of precision errors: How to measure the reproducibility of bone densitometry techniques
    • Gluer CC, Blake G, Lu Y, Blunt BA, Jergas M, Genant HK (1995) Accurate assessment of precision errors: how to measure the reproducibility of bone densitometry techniques. Osteoporos Int 5: 262-280
    • (1995) Osteoporos Int , vol.5 , pp. 262-280
    • Gluer, C.C.1    Blake, G.2    Lu, Y.3    Blunt, B.A.4    Jergas, M.5    Genant, H.K.6