메뉴 건너뛰기




Volumn , Issue , 1999, Pages 345-347

Current monitoring for detecting inter-turn short circuits in induction motors

Author keywords

[No Author keywords available]

Indexed keywords

AIR-GAP FLUX; CURRENT MONITORING; INTER-TURN SHORT CIRCUIT; LOWER SIDEBANDS; ROTATIONAL FREQUENCY;

EID: 0002782292     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMDC.1999.769110     Document Type: Conference Paper
Times cited : (27)

References (7)
  • 1
    • 0017965046 scopus 로고
    • Analysis of winding failures in three-phase squirrel cage induction motors
    • Bonnet, A. H.:"Analysis of Winding Failures in Three-Phase Squirrel Cage Induction Motors", IEEE Trans, on IA, Vol. 14, No. 3,1978, pp. 223-226.
    • (1978) IEEE Trans, on IA , vol.14 , Issue.3 , pp. 223-226
    • Bonnet, A.H.1
  • 2
    • 0027657567 scopus 로고
    • Partial discharges in hv machines; Initial considerations for a pd specification
    • Wood, J. W, Sedding, H. G., Hogg, W. K., Kemp, I. J., Zhu, H.:"Partial Discharges in HV Machines; Initial Considerations for a PD Specification", Proc. IEE-A, Vol. 140, No. 5,1993, pp. 409-416.
    • (1993) Proc. IEE-A , vol.140 , Issue.5 , pp. 409-416
    • Wood, W.J.1    Sedding, H.G.2    Hogg, W.K.3    Kemp, I.J.4    Zhu, H.5
  • 3
    • 0018491939 scopus 로고
    • Radio frequency sensing of incipient arcing faults within large turbine generators
    • Harrold, R. T., Emery, F. T., Murphy, S. A., Drinkut, S. A.:"Radio Frequency Sensing of Incipient Arcing Faults Within Large Turbine Generators", IEEE Trans, on PAS, Vol. 98, No. 4,1979, pp. 1167-1173.
    • (1979) IEEE Trans, on PAS , vol.98 , Issue.4 , pp. 1167-1173
    • Harrold, R.T.1    Emery, F.T.2    Murphy, S.A.3    Drinkut, S.A.4
  • 4
    • 0022576973 scopus 로고
    • Condition monitoring of electrical drives
    • Penman, J., Dey, M. N., Tait, A. J., Bryan, W. E.:"Condition monitoring of electrical drives", Proc. IEE, vol. 133, Pt. B, No 3,1986, pp. 142-148.
    • (1986) Proc. IEE , vol.133 , Issue.3 PART B , pp. 142-148
    • Penman, J.1    Dey, M.N.2    Tait, A.J.3    Bryan, W.E.4
  • 6
    • 0027831326 scopus 로고
    • An on-line method to detect incipient failure of turn insulation in random-wound motors
    • Sottile, J., Kohler, J. L.:"An On-Line Method to Detect Incipient Failure of Turn Insulation in Random-Wound Motors", IEEE Trans, on Energy Conversion, Vol. 8, No. 4,1993, pp 762-768.
    • (1993) IEEE Trans, on Energy Conversion , vol.8 , Issue.4 , pp. 762-768
    • Sottile, J.1    Kohler, J.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.