메뉴 건너뛰기




Volumn 38, Issue 34, 1999, Pages 7026-7034

Analysis of a low-finesse Fabry–Perot sensing interferometer illuminated by a multimode optical fiber

Author keywords

[No Author keywords available]

Indexed keywords


EID: 0002736868     PISSN: 1559128X     EISSN: 21553165     Source Type: Journal    
DOI: 10.1364/AO.38.007026     Document Type: Article
Times cited : (28)

References (13)
  • 1
    • 0344148174 scopus 로고
    • Fiber-optic Fabry-Perot interferometer and its sensor applications
    • T. Yoshino, K. Kurosawa, K. Itoh, and T. Ose, “Fiber-optic Fabry-Perot interferometer and its sensor applications,” IEEE Trans. Microwave Theory Tech. MTT-30, 1612-1621 (1982).
    • (1982) IEEE Trans. Microwave Theory Tech. , vol.MTT-30 , pp. 1612-1621
    • Yoshino, T.1    Kurosawa, K.2    Itoh, K.3    Ose, T.4
  • 2
    • 0026245019 scopus 로고
    • Development of medical pressure and temperature sensors employing optical spectrum modulation
    • R. A. Wolthius, G. L. Mitchell, E. Saaski, J. C. Hartl, and M. A. Afromowitz, “Development of medical pressure and temperature sensors employing optical spectrum modulation,” IEEE Trans. Biomed. Eng. 38, 974-981 (1991).
    • (1991) IEEE Trans. Biomed. Eng. , vol.38 , pp. 974-981
    • Wolthius, R.A.1    Mitchell, G.L.2    Saaski, E.3    Hartl, J.C.4    Afromowitz, M.A.5
  • 3
    • 84975571726 scopus 로고
    • Quadrature phase-shifted, extrinsic Fabry-Perot optical fiber sensors
    • A. K. Murphy, M. F. Gunter, A. M. Vengsarker, and R. O. Claus, “Quadrature phase-shifted, extrinsic Fabry-Perot optical fiber sensors,” Opt. Lett. 16, 273-275 (1991).
    • (1991) Opt. Lett. , vol.16 , pp. 273-275
    • Murphy, A.K.1    Gunter, M.F.2    Vengsarker, A.M.3    Claus, R.O.4
  • 4
    • 3042883191 scopus 로고
    • Exact analysis of the EFPI optical fiber sensor using Kirchhoffs diffraction formalism,”
    • V. Arya, M. J. de Vries, K. A. Murphy, A. Wang, and R. O. Claus, “Exact analysis of the EFPI optical fiber sensor using Kirchhoff’s diffraction formalism,” Opt. Fiber Technol. 1, 380-384 (1995).
    • (1995) Opt. Fiber Technol. , vol.1 , pp. 380-384
    • Arya, V.1    De Vries, M.J.2    Murphy, K.A.3    Wang, A.4    Claus, R.O.5
  • 5
    • 0020915757 scopus 로고
    • Fiber optic colour sensors based on Fabry-Perot interferometry
    • Optical Society of America, Washington, D.C
    • E. R. Cox and B. E. Jones, “Fiber optic colour sensors based on Fabry-Perot interferometry,” in Proceedings of the First International Conference on Optical Fiber Sensors (Optical Society of America, Washington, D.C., 1983), pp. 122-126.
    • (1983) Proceedings of the First International Conference on Optical Fiber Sensors , pp. 122-126
    • Cox, E.R.1    Jones, B.E.2
  • 6
    • 0031118065 scopus 로고    scopus 로고
    • A miniature optical fibre ultrasonic hydrophone using a Fabry-Perot polymer film interferometer
    • P. C. Beard and T. N. Mills, “A miniature optical fibre ultrasonic hydrophone using a Fabry-Perot polymer film interferometer,” Electron. Lett. 33, 801-803 (1997).
    • (1997) Electron. Lett. , vol.33 , pp. 801-803
    • Beard, P.C.1    Mills, T.N.2
  • 7
    • 0031963182 scopus 로고    scopus 로고
    • Acoustic performance and clinical use of a fibre-optic hydrophone, Ultrasound Med
    • A. J. Coleman, E. Draguioti, R. Tiptaf, N. Shotri, and J. E. Saunders, “Acoustic performance and clinical use of a fibre-optic hydrophone,” Ultrasound Med. Biol. 24, 143-151 (1998).
    • (1998) Biol. , vol.24 , pp. 143-151
    • Coleman, A.J.1    Draguioti, E.2    Tiptaf, R.3    Shotri, N.4    Saunders, J.E.5
  • 8
    • 0030080611 scopus 로고    scopus 로고
    • Extrinsic optical fiber ultrasound sensor with a thin polymer film as a low-finesse Fabry-Perot interferometer
    • P. C. Beard and T. N. Mills, “Extrinsic optical fiber ultrasound sensor with a thin polymer film as a low-finesse Fabry-Perot interferometer,” Appl. Opt. 35, 663-675 (1996).
    • (1996) Appl. Opt. , vol.35 , pp. 663-675
    • Beard, P.C.1    Mills, T.N.2
  • 9
    • 0000973144 scopus 로고    scopus 로고
    • Optical fiber photoacoustic-photothermal probe
    • P. C. Beard, F. Perennes, E. Draguioti, and T. N. Mills, “Optical fiber photoacoustic-photothermal probe,” Opt. Lett. 23, 1235-1237 (1998).
    • (1998) Opt. Lett. , vol.23 , pp. 1235-1237
    • Beard, P.C.1    Perennes, F.2    Draguioti, E.3    Mills, T.N.4
  • 11
    • 3042875250 scopus 로고    scopus 로고
    • Analysis of the performance of imperfect fiber endfaces on the performance of extrinsic Fabry-Perot interferometric optical fiber sensors
    • V. Arya, M. J. de Vries, M. Athreya, A. Wang, and R. O. Claus, “Analysis of the performance of imperfect fiber endfaces on the performance of extrinsic Fabry-Perot interferometric optical fiber sensors,” Opt. Eng. 35, 2262-2265 (1996).
    • (1996) Opt. Eng. , vol.35 , pp. 2262-2265
    • Arya, V.1    De Vries, M.J.2    Athreya, M.3    Wang, A.4    Claus, R.O.5
  • 12
    • 0004038250 scopus 로고
    • 2nd ed. (Addison-Wesley, Reading, Mass
    • E. Hecht, Optics, 2nd ed. (Addison-Wesley, Reading, Mass., 1987), pp. 364-366.
    • (1987) Optics , pp. 364-366
    • Hecht, E.1
  • 13
    • 0000961967 scopus 로고
    • Optical fiber sensing with a low-finesse Fabry-Perot cavity
    • J. L. Santos, A. P. Leite, and D. A. Jackson, “Optical fiber sensing with a low-finesse Fabry-Perot cavity,” Appl. Opt. 31, 7361-7366 (1992)
    • (1992) Appl. Opt. , vol.31 , pp. 7361-7366
    • Santos, J.L.1    Leite, A.P.2    Jackson, D.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.