메뉴 건너뛰기




Volumn 10, Issue 1, 2000, Pages 14-19

Computer-assisted periacetabular osteotomy

Author keywords

Computer assistance; Pelvic osteotomy

Indexed keywords


EID: 0002551007     PISSN: 10486666     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1048-6666(00)80038-5     Document Type: Article
Times cited : (5)

References (18)
  • 1
    • 0025829359 scopus 로고
    • The acetabular rim syndrome: A clinical presentation of dysplasia of the hip
    • Klaue K, Durnin CW, Ganz R: The acetabular rim syndrome: A clinical presentation of dysplasia of the hip. J Bone Joint Surg Br 73:423-429, 1991
    • (1991) J Bone Joint Surg Br , vol.73 , pp. 423-429
    • Klaue, K.1    Durnin, C.W.2    Ganz, R.3
  • 2
    • 0023026367 scopus 로고
    • Etiology of osteoarthritis of the hip
    • Harris WH: Etiology of osteoarthritis of the hip. Clin Orthop 212:20-33, 1986
    • (1986) Clin Orthop , vol.212 , pp. 20-33
    • Harris, W.H.1
  • 3
    • 77951387059 scopus 로고
    • Beckenosteotomie zur Pfannendachplastik
    • Chiari K: Beckenosteotomie zur Pfannendachplastik. Wien Med Wochenschr 103:707-714, 1953
    • (1953) Wien Med Wochenschr , vol.103 , pp. 707-714
    • Chiari, K.1
  • 4
    • 0023740810 scopus 로고
    • A new periacetabular osteotomy for the treatment of hip dysplasias: Technique and preliminary results
    • Ganz R, Klaue K, Vinh TS, et al: A new periacetabular osteotomy for the treatment of hip dysplasias: Technique and preliminary results. Clin Orthop 232:26-36, 1988
    • (1988) Clin Orthop , vol.232 , pp. 26-36
    • Ganz, R.1    Klaue, K.2    Vinh, T.S.3
  • 5
    • 0345593403 scopus 로고    scopus 로고
    • Bernese periacetabular osteotomy: A minimal follow-up of 10 years
    • Siebenrock KA, Schöll E, Lottenbach M, et al: Bernese periacetabular osteotomy: A minimal follow-up of 10 years. Clin Orthop 363:9-20, 1999
    • (1999) Clin Orthop , vol.363 , pp. 9-20
    • Siebenrock, K.A.1    Schöll, E.2    Lottenbach, M.3
  • 6
    • 0031761927 scopus 로고    scopus 로고
    • Berner periazetabuläre Osteotomie
    • Leunig M, Ganz R: Berner periazetabuläre Osteotomie. Orthopäde 27:743-750, 1998
    • (1998) Orthopäde , vol.27 , pp. 743-750
    • Leunig, M.1    Ganz, R.2
  • 7
    • 0023740808 scopus 로고
    • CT evaluation of coverage and congruency of the hip prior to osteotomy
    • Klaue K, Wallin A, Ganz R: CT evaluation of coverage and congruency of the hip prior to osteotomy. Clin Orthop 232:15-25, 1988
    • (1988) Clin Orthop , vol.232 , pp. 15-25
    • Klaue, K.1    Wallin, A.2    Ganz, R.3
  • 8
    • 0030909607 scopus 로고    scopus 로고
    • Planning and insertion of pedicle screws with computer assistance
    • Berlemann U, Monin D, Arm E, et al: Planning and insertion of pedicle screws with computer assistance. J Spinal Disord 10:117-124, 1997
    • (1997) J Spinal Disord , vol.10 , pp. 117-124
    • Berlemann, U.1    Monin, D.2    Arm, E.3
  • 9
    • 0031057090 scopus 로고    scopus 로고
    • Accuracy of computer-assisted pedicle screw placement - An in vivo CT analysis
    • Schwarzenbach O, Berlemann U, Jost B, et al: Accuracy of computer-assisted pedicle screw placement - An in vivo CT analysis. Spine 22:452-458, 1997
    • (1997) Spine , vol.22 , pp. 452-458
    • Schwarzenbach, O.1    Berlemann, U.2    Jost, B.3
  • 10
    • 0345084465 scopus 로고    scopus 로고
    • Computer assistance for pelvic osteotomies
    • Langlotz F, Bächler R, Berlemann U, et al: Computer assistance for pelvic osteotomies. Clin Orthop 354:92-102, 1998
    • (1998) Clin Orthop , vol.354 , pp. 92-102
    • Langlotz, F.1    Bächler, R.2    Berlemann, U.3
  • 11
    • 0033033058 scopus 로고    scopus 로고
    • A comparison of different surgical approaches for the periacetabular osteotomy
    • Hussel G, Mast JW, Howie D, et al: A comparison of different surgical approaches for the periacetabular osteotomy. Clin Orthop 363:64-72, 1999
    • (1999) Clin Orthop , vol.363 , pp. 64-72
    • Hussel, G.1    Mast, J.W.2    Howie, D.3
  • 12
    • 0027200992 scopus 로고
    • The treatment of acetabular fractures through the ilioinguinal approach
    • Letournel E: The treatment of acetabular fractures through the ilioinguinal approach. Clin Orthop 292:62-76, 1993
    • (1993) Clin Orthop , vol.292 , pp. 62-76
    • Letournel, E.1
  • 14
    • 0002375331 scopus 로고    scopus 로고
    • Registration for computer-integrated surgery: Methodology, state of the art
    • Taylor RH, Lavallée S, Burdea GC, Mösges R (eds): Cambridge, London, MIT Press
    • Lavallée S: Registration for computer-integrated surgery: Methodology, state of the art. in Taylor RH, Lavallée S, Burdea GC, Mösges R (eds): Computer-Integrated Surgery. Cambridge, London, MIT Press, 1996, pp 77-97
    • (1996) Computer-Integrated Surgery , pp. 77-97
    • Lavallée, S.1
  • 15
    • 0031412924 scopus 로고    scopus 로고
    • The first twelve cases of computer assisted periacetabular osteotomy
    • Langlotz F, Stucki M, Bächler R, et al: The first twelve cases of computer assisted periacetabular osteotomy. Comput Aided Surg 2:317-326, 1997
    • (1997) Comput Aided Surg , vol.2 , pp. 317-326
    • Langlotz, F.1    Stucki, M.2    Bächler, R.3
  • 16
    • 33750650124 scopus 로고    scopus 로고
    • Computer navigation system for rotational acetabular osteotomy in the hip joint
    • Lemke HU, Vannier MW, Inamura K, Farman A (eds): Amsterdam, Elsevier
    • Nishii T, Sugano N, Ohzono K, et al: Computer navigation system for rotational acetabular osteotomy in the hip joint, in Lemke HU, Vannier MW, Inamura K, Farman A (eds): Computer Assisted Radiology. Amsterdam, Elsevier, 1998, p 913
    • (1998) Computer Assisted Radiology , pp. 913
    • Nishii, T.1    Sugano, N.2    Ohzono, K.3
  • 17
    • 0030841544 scopus 로고    scopus 로고
    • Man-machine interfaces in computer assisted surgery
    • Visarius H, Gong J, Scheer C, et al: Man-machine interfaces in computer assisted surgery. Comp Aid Surg 2:102-107, 1997
    • (1997) Comp Aid Surg , vol.2 , pp. 102-107
    • Visarius, H.1    Gong, J.2    Scheer, C.3
  • 18
    • 33750677239 scopus 로고    scopus 로고
    • Restricted surface matching - Numerical optimization and technical evaluation
    • submitted
    • Bächler R, Bunke H, Nolte LP: Restricted surface matching - Numerical optimization and technical evaluation. Comput Aided Surg (submitted)
    • Comput Aided Surg
    • Bächler, R.1    Bunke, H.2    Nolte, L.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.