메뉴 건너뛰기




Volumn 10, Issue 1, 2000, Pages 64-68

Image-guided spinal surgery

Author keywords

Image guidea surgery; Spine

Indexed keywords


EID: 0002099422     PISSN: 10486666     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1048-6666(00)80044-0     Document Type: Article
Times cited : (6)

References (28)
  • 1
    • 0002936907 scopus 로고
    • Image-guided intraoperative spinal localization
    • Andrews RJ (ed): Baltimore, MD, Williams and Wilkins
    • Foley KT, Smith KR, Bucholz RD: Image-guided intraoperative spinal localization, in Andrews RJ (ed): Intraoperative Neuroprotection. Baltimore, MD, Williams and Wilkins, 1995, pp 325-340
    • (1995) Intraoperative Neuroprotection , pp. 325-340
    • Foley, K.T.1    Smith, K.R.2    Bucholz, R.D.3
  • 4
    • 0029893644 scopus 로고    scopus 로고
    • Accuracy of pedicle screw placement in lumbar vertebrae
    • Castro WHM, Halm H, Jerosch J, et al: Accuracy of pedicle screw placement in lumbar vertebrae. Spine 21:1320-1324, 1996
    • (1996) Spine , vol.21 , pp. 1320-1324
    • Castro, W.H.M.1    Halm, H.2    Jerosch, J.3
  • 5
    • 0027484342 scopus 로고
    • Complications associated with the technique of pedicle screw fixation: A selected survey of ABS members
    • Esses SI, Barton LS, Vadim D: Complications associated with the technique of pedicle screw fixation: A selected survey of ABS members. Spine 18:2231-2239, 1993
    • (1993) Spine , vol.18 , pp. 2231-2239
    • Esses, S.I.1    Barton, L.S.2    Vadim, D.3
  • 6
    • 0028882788 scopus 로고
    • Complications of posterior cervical plating
    • Heller J, Silcox D, Sutterlin C: Complications of posterior cervical plating. Spine 20:2442-2448, 1995
    • (1995) Spine , vol.20 , pp. 2442-2448
    • Heller, J.1    Silcox, D.2    Sutterlin, C.3
  • 7
    • 0003115598 scopus 로고
    • Internal fixation with pedicle screws
    • White AH, Rothman RH, Roy CD (eds). St. Louis, MO, Mosby
    • Hsu J, Zucherman JF, White A, et al: Internal fixation with pedicle screws, in White AH, Rothman RH, Roy CD (eds). Lumbar Spinal Surgery. St. Louis, MO, Mosby, 1987, pp 322-338
    • (1987) Lumbar Spinal Surgery , pp. 322-338
    • Hsu, J.1    Zucherman, J.F.2    White, A.3
  • 8
    • 0029044493 scopus 로고
    • Accuracy of pedicle screw placement in lumbar fusion by plain radiographs and CT
    • Farber GL, Place HM, Mazur RA, et al: Accuracy of pedicle screw placement in lumbar fusion by plain radiographs and CT. Spine 20:1494-1499, 1995
    • (1995) Spine , vol.20 , pp. 1494-1499
    • Farber, G.L.1    Place, H.M.2    Mazur, R.A.3
  • 9
    • 0031438992 scopus 로고    scopus 로고
    • Accuracy of pedicle screw placement: A prospective CT study in 30 low back patients
    • Laine T, Makitalo K, Schlenzka D, et al: Accuracy of pedicle screw placement: A prospective CT study in 30 low back patients. Eur Spine J 6:402-405, 1997
    • (1997) Eur Spine J , vol.6 , pp. 402-405
    • Laine, T.1    Makitalo, K.2    Schlenzka, D.3
  • 10
    • 0031413907 scopus 로고    scopus 로고
    • Pedicle screw instrumentation of the thoracic spine in idiopathic scoliosis
    • Lilijenqvist UR, Halm HFH, Link TM: Pedicle screw instrumentation of the thoracic spine in idiopathic scoliosis. Spine 22:2239-2245, 1997
    • (1997) Spine , vol.22 , pp. 2239-2245
    • Lilijenqvist, U.R.1    Halm, H.F.H.2    Link, T.M.3
  • 11
    • 0030973318 scopus 로고    scopus 로고
    • Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique
    • Madawi A, Casey A, Solanki G, et al: Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique. J Neurosurg 86:961-968, 1997
    • (1997) J Neurosurg , vol.86 , pp. 961-968
    • Madawi, A.1    Casey, A.2    Solanki, G.3
  • 12
    • 0029773637 scopus 로고    scopus 로고
    • Accuracy of pedicle screw placement with the assistance of lateral plain radiography
    • Odgers CJ, Vaccaro AR, Pollack ME, et al: Accuracy of pedicle screw placement with the assistance of lateral plain radiography. J Spinal Disord 9:334-338, 1996
    • (1996) J Spinal Disord , vol.9 , pp. 334-338
    • Odgers, C.J.1    Vaccaro, A.R.2    Pollack, M.E.3
  • 13
    • 0029070230 scopus 로고
    • Segmental pedicle screw fixation in the treatment of thoracic idiopathic scoliosis
    • Suk S, Lee CK, Kim WJ, et al: Segmental pedicle screw fixation in the treatment of thoracic idiopathic scoliosis. Spine 20:1399-1405, 1995
    • (1995) Spine , vol.20 , pp. 1399-1405
    • Suk, S.1    Lee, C.K.2    Kim, W.J.3
  • 15
    • 0023790873 scopus 로고
    • Spinal pedicle fixation: Reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement
    • Weinstein JN, Spratt KF, Spengler D, et al: Spinal pedicle fixation: Reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement. Spine 13:1012-1018, 1988
    • (1988) Spine , vol.13 , pp. 1012-1018
    • Weinstein, J.N.1    Spratt, K.F.2    Spengler, D.3
  • 16
    • 0032076473 scopus 로고    scopus 로고
    • Anatomic consideration of pedicle screw placement in the thoracic spine
    • Xu R, Ebraheim NA, Ou Y, et al: Anatomic consideration of pedicle screw placement in the thoracic spine. Spine 23:1065-1068, 1998
    • (1998) Spine , vol.23 , pp. 1065-1068
    • Xu, R.1    Ebraheim, N.A.2    Ou, Y.3
  • 17
    • 0030909607 scopus 로고    scopus 로고
    • Planning and insertion of pedicle screws with computer assistance
    • Berlermann U, Monin D, Arm E, et al: Planning and insertion of pedicle screws with computer assistance. J Spinal Disord 10:117-124, 1997
    • (1997) J Spinal Disord , vol.10 , pp. 117-124
    • Berlermann, U.1    Monin, D.2    Arm, E.3
  • 18
    • 0030952473 scopus 로고    scopus 로고
    • In-vitro simulation: Early results of stereotaxy for pedicle screw placement
    • Carl AL, Khanuja HS, Sachs BL, et al: In-vitro simulation: Early results of stereotaxy for pedicle screw placement. Spine 22:1160-1164, 1997
    • (1997) Spine , vol.22 , pp. 1160-1164
    • Carl, A.L.1    Khanuja, H.S.2    Sachs, B.L.3
  • 19
    • 85031550911 scopus 로고    scopus 로고
    • Atlantoaxial transarticular screw fixation: Risk assessment and bone morphology using an image guidance system
    • in press
    • Foley KT, Silveri CP, Shah S, et al: Atlantoaxial transarticular screw fixation: Risk assessment and bone morphology using an image guidance system. Spine (in press).
    • Spine
    • Foley, K.T.1    Silveri, C.P.2    Shah, S.3
  • 22
    • 0006026676 scopus 로고    scopus 로고
    • Frameless stereotactic guidance of C1-2 transarticular screw placement: Clinical experience
    • abstr
    • Foley KT, Smith MM: Frameless stereotactic guidance of C1-2 transarticular screw placement: Clinical experience. J Neurosurg 86:360A, 1997 (abstr)
    • (1997) J Neurosurg , vol.86
    • Foley, K.T.1    Smith, M.M.2
  • 23
    • 0029760974 scopus 로고    scopus 로고
    • Computer-aided pedicle screw placement using frameless stereotaxis
    • Glossop ND, Hu RW, Randle JA: Computer-aided pedicle screw placement using frameless stereotaxis. Spine 21:2026-2034, 1996
    • (1996) Spine , vol.21 , pp. 2026-2034
    • Glossop, N.D.1    Hu, R.W.2    Randle, J.A.3
  • 24
    • 0029157802 scopus 로고
    • Application of frameless stereotaxy to pedicle screw fixation of the spine
    • Kalfas IH, Kormos DW, Murphy MA, et al: Application of frameless stereotaxy to pedicle screw fixation of the spine. J Neurosurg 83:641-647, 1995
    • (1995) J Neurosurg , vol.83 , pp. 641-647
    • Kalfas, I.H.1    Kormos, D.W.2    Murphy, M.A.3
  • 25
    • 0004912991 scopus 로고    scopus 로고
    • Placement of pedicle screws in the cervical spine: Comparative accuracy of cervical pedicle placement using three techniques
    • Palm Beach, FL, December
    • Kramer DL, Ludwig SC, Balderston RA, et al: Placement of pedicle screws in the cervical spine: Comparative accuracy of cervical pedicle placement using three techniques. 24th Annual Meeting of the Cervical Spine Research Society, Palm Beach, FL, December 1996
    • (1996) 24th Annual Meeting of the Cervical Spine Research Society
    • Kramer, D.L.1    Ludwig, S.C.2    Balderston, R.A.3
  • 26
    • 0030926450 scopus 로고    scopus 로고
    • Improved accuracy of pedicle screw insertion with computer-assisted surgery
    • Laine T, Schlenzka D, Makitalo K, et al: Improved accuracy of pedicle screw insertion with computer-assisted surgery. Spine 22:1254-1258, 1997
    • (1997) Spine , vol.22 , pp. 1254-1258
    • Laine, T.1    Schlenzka, D.2    Makitalo, K.3
  • 27
    • 0031696110 scopus 로고    scopus 로고
    • Pedicle screw placement using image guided techniques
    • Merloz P, Tonetti J, Pittet L, et al: Pedicle screw placement using image guided techniques. Clin Orthop 354:39-48, 1998
    • (1998) Clin Orthop , vol.354 , pp. 39-48
    • Merloz, P.1    Tonetti, J.2    Pittet, L.3
  • 28
    • 0031057090 scopus 로고    scopus 로고
    • Accuracy of computer-assisted pedicle screw placement: An in-vivo computed tomography analysis
    • Schwarzenbach O, Berlemann U, Jost B, et al: Accuracy of computer-assisted pedicle screw placement: An in-vivo computed tomography analysis. Spine 22:452-458, 1997
    • (1997) Spine , vol.22 , pp. 452-458
    • Schwarzenbach, O.1    Berlemann, U.2    Jost, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.