메뉴 건너뛰기




Volumn 93, Issue 1, 1998, Pages 67-74

Using end-tidal carbon dioxide to monitor patients

Author keywords

[No Author keywords available]

Indexed keywords


EID: 0001962131     PISSN: 87507943     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Conference Paper
Times cited : (10)

References (27)
  • 1
    • 0019981391 scopus 로고
    • Capnographic monitoring in small animal anesthesia
    • Moens, Y.; Verstraiten, W.: Capnographic monitoring in small animal anesthesia. JAAHA 18:659-678; 1982.
    • (1982) JAAHA , vol.18 , pp. 659-678
    • Moens, Y.1    Verstraiten, W.2
  • 2
    • 0348113293 scopus 로고
    • Anesthesia Patient Safety Foundation, Park Ridge, Ill.
    • American Society of Anesthesiologists: Standards for Basic Intraoperative Monitoring. Anesthesia Patient Safety Foundation, Park Ridge, Ill., 1992.
    • (1992) Standards for Basic Intraoperative Monitoring
  • 3
    • 0026592293 scopus 로고
    • Noninvasive assessment of blood gases
    • Clark, J.S. et al: Noninvasive assessment of blood gases. Am. Rev. Respir. Dis. 145:220-252; 1992.
    • (1992) Am. Rev. Respir. Dis. , vol.145 , pp. 220-252
    • Clark, J.S.1
  • 4
    • 0019628181 scopus 로고
    • Use of infra-red carbon dioxide analysis during general anesthesia in the horse
    • Moens, Y.; DeMoor, A.: Use of infra-red carbon dioxide analysis during general anesthesia in the horse. Eq. Vet. J. 13:229-234; 1981.
    • (1981) Eq. Vet. J. , vol.13 , pp. 229-234
    • Moens, Y.1    DeMoor, A.2
  • 5
    • 0003109245 scopus 로고
    • Blood circulation and the cardiovascular system
    • (M.J. Swenson, ed.). Cornell University Press, Ithaca, N.Y.
    • Swenson, M.J.: Blood circulation and the cardiovascular system. Duke's Physiology of Domestic Animals, 10th Ed. (M.J. Swenson, ed.). Cornell University Press, Ithaca, N.Y., 1984; pp 15-40.
    • (1984) Duke's Physiology of Domestic Animals, 10th Ed. , pp. 15-40
    • Swenson, M.J.1
  • 6
    • 0019426820 scopus 로고
    • Relationship between arterial and peak expired carbon dioxide pressure during anesthesia and factors influencing the difference
    • Whitesell, R. et al. Relationship between arterial and peak expired carbon dioxide pressure during anesthesia and factors influencing the difference. Anesth. Analg. 60:508-512; 1981.
    • (1981) Anesth. Analg. , vol.60 , pp. 508-512
    • Whitesell, R.1
  • 7
    • 0002847889 scopus 로고
    • Monitoring gas exchange during mechanical ventilation
    • (M.J. Tobin, ed.). McGraw-Hill, New York, N.Y.
    • Jubran, A.; Tobin, M.J.: Monitoring gas exchange during mechanical ventilation. Principles and Practice of Mechanical Ventilation (M.J. Tobin, ed.). McGraw-Hill, New York, N.Y., 1994; pp 919-943.
    • (1994) Principles and Practice of Mechanical Ventilation , pp. 919-943
    • Jubran, A.1    Tobin, M.J.2
  • 8
    • 0343106765 scopus 로고
    • Respiration in mammals
    • (M.J. Swenson, ed.). Cornell University Press, Ithaca, N.Y.
    • Reece, W.O.: Respiration in mammals. Duke's Physiology of Domestic Animals, 10th Ed. (M.J. Swenson, ed.). Cornell University Press, Ithaca, N.Y., 1984; pp 226-254.
    • (1984) Duke's Physiology of Domestic Animals, 10th Ed. , pp. 226-254
    • Reece, W.O.1
  • 9
    • 0029098479 scopus 로고
    • Intraoperative end-tidal carbon dioxide values and derived calculations correlated with outcome: Prognosis and capnography
    • Domsky, M. et al: Intraoperative end-tidal carbon dioxide values and derived calculations correlated with outcome: Prognosis and capnography. Crit. Care Med. 23:1497-1503; 1995.
    • (1995) Crit. Care Med. , vol.23 , pp. 1497-1503
    • Domsky, M.1
  • 10
    • 0040114343 scopus 로고
    • Dealing with a new method for gas analysis with ultrared light without spectral analysis
    • Luft, K.: Dealing with a new method for gas analysis with ultrared light without spectral analysis. Ztschr. F. Techn. Phys. 24:97; 1943.
    • (1943) Ztschr. F. Techn. Phys. , vol.24 , pp. 97
    • Luft, K.1
  • 11
    • 72849165961 scopus 로고
    • 2 tension difference in anesthetized man
    • 2 tension difference in anesthetized man. J. Appl. Physiol. 15:383-389; 1960.
    • (1960) J. Appl. Physiol. , vol.15 , pp. 383-389
    • Nunn, J.F.1    Hill, D.W.2
  • 12
    • 0019001513 scopus 로고
    • 2 during various ventilatory regimens in halothane-anesthetized dogs
    • 2 during various ventilatory regimens in halothane-anesthetized dogs. AJVR 41:610-612; 1980.
    • (1980) AJVR , vol.41 , pp. 610-612
    • Hightower, C.E.1
  • 13
    • 0023305008 scopus 로고
    • Mass spectrometer and/or capnograph use during low-flow closed circuit anesthesia administration
    • Huffman, L.M.; Riddle, R.T.: Mass spectrometer and/or capnograph use during low-flow closed circuit anesthesia administration. Anesthesiology 66:439-440; 1987.
    • (1987) Anesthesiology , vol.66 , pp. 439-440
    • Huffman, L.M.1    Riddle, R.T.2
  • 14
    • 0014923035 scopus 로고
    • Hidden hypercapnia in hemorrhagic hypotension
    • Halmagyi, D.F.J. et al: Hidden hypercapnia in hemorrhagic hypotension. Anesthesiology 33:594-601; 1970.
    • (1970) Anesthesiology , vol.33 , pp. 594-601
    • Halmagyi, D.F.J.1
  • 15
    • 0020973765 scopus 로고
    • 2 between arterial blood and peak expired gas during anesthesia
    • 2 between arterial blood and peak expired gas during anesthesia. Anesth. Analg. 62:1065-1069; 1983.
    • (1983) Anesth. Analg. , vol.62 , pp. 1065-1069
    • Raemer, D.B.1
  • 16
    • 0023160209 scopus 로고
    • 2 monitoring in infants and children ventilated with either a partial rebreathing or a non-rebreathing circuit
    • 2 monitoring in infants and children ventilated with either a partial rebreathing or a non-rebreathing circuit. Anesthesiology 66:405-410; 1987.
    • (1987) Anesthesiology , vol.66 , pp. 405-410
    • Badgwell, J.M.1
  • 17
    • 0021939871 scopus 로고
    • 2 tension and alveolar dead space in isoflurane-anesthetized ponies
    • 2 tension and alveolar dead space in isoflurane-anesthetized ponies. AJVR 46:597-599; 1985.
    • (1985) AJVR , vol.46 , pp. 597-599
    • Meyer, R.E.1    Short, C.E.2
  • 18
    • 0026616857 scopus 로고
    • 2 values in isoflurane-anesthetized equine neonates
    • 2 values in isoflurane-anesthetized equine neonates. AJVR 53:1617-1621; 1992.
    • (1992) AJVR , vol.53 , pp. 1617-1621
    • Geiser, D.R.1    Rohrbach, B.W.2
  • 19
    • 0023671746 scopus 로고
    • Capnographic monitoring during anesthesia with controlled ventilation in the horse
    • Crib, P.H.: Capnographic monitoring during anesthesia with controlled ventilation in the horse. Vet. Surg. 17:48-52; 1988.
    • (1988) Vet. Surg. , vol.17 , pp. 48-52
    • Crib, P.H.1
  • 20
    • 0017622955 scopus 로고
    • 2 in the human neonate and the rabbit
    • 2 in the human neonate and the rabbit. Br. J. Anaesth. 49:761-764; 1977.
    • (1977) Br. J. Anaesth. , vol.49 , pp. 761-764
    • Evans, J.M.1
  • 21
    • 84995123544 scopus 로고
    • Practicality and usefulness, and limits of end-tidal carbon dioxide monitoring in critical small animal patients
    • Hendricks, J.C.; King, L.G.: Practicality and usefulness, and limits of end-tidal carbon dioxide monitoring in critical small animal patients. J. Vet. Emerg. Crit. Care 4:29-39; 1994.
    • (1994) J. Vet. Emerg. Crit. Care , vol.4 , pp. 29-39
    • Hendricks, J.C.1    King, L.G.2
  • 22
    • 0022510483 scopus 로고
    • Intraoperative events diagnosed by expired carbon dioxide monitoring in children
    • Cotè, C.J. et al: Intraoperative events diagnosed by expired carbon dioxide monitoring in children. Can. Anaesth. Soc. J. 33:315-320; 1986.
    • (1986) Can. Anaesth. Soc. J. , vol.33 , pp. 315-320
    • Cotè, C.J.1
  • 23
    • 0020961807 scopus 로고
    • Early detection of endotracheal tube accidents by monitoring carbon dioxide concentration in respiratory gas
    • Murray, I.P.; Modell, J.H.: Early detection of endotracheal tube accidents by monitoring carbon dioxide concentration in respiratory gas. Anesthesiology 59:344-346; 1983.
    • (1983) Anesthesiology , vol.59 , pp. 344-346
    • Murray, I.P.1    Modell, J.H.2
  • 24
    • 0022372478 scopus 로고
    • Cardiac output and end-tidal carbon dioxide
    • Weil, M.H. et al: Cardiac output and end-tidal carbon dioxide. Crit. Care Med. 13:907-911; 1985.
    • (1985) Crit. Care Med. , vol.13 , pp. 907-911
    • Weil, M.H.1
  • 25
    • 0016286771 scopus 로고
    • The arterial to end-expiratory carbon dioxide tension gradient in acute pulmonary embolism and other cardiopulmonary diseases
    • Hatle, L.; Rokseth, R.: The arterial to end-expiratory carbon dioxide tension gradient in acute pulmonary embolism and other cardiopulmonary diseases. Chest 66:352-357; 1974.
    • (1974) Chest , vol.66 , pp. 352-357
    • Hatle, L.1    Rokseth, R.2
  • 26
    • 0023889971 scopus 로고
    • Efficacy of pulse oximetry and capnometry in postoperative ventilatory weaning
    • Niehoff, J. et al. Efficacy of pulse oximetry and capnometry in postoperative ventilatory weaning. Crit. Care Med. 16:701-705; 1988.
    • (1988) Crit. Care Med. , vol.16 , pp. 701-705
    • Niehoff, J.1
  • 27
    • 0023881196 scopus 로고
    • Expired carbon dioxide: A noninvasive monitor of cardiopulmonary resuscitation
    • Gudipati, C.V. et al: Expired carbon dioxide: A noninvasive monitor of cardiopulmonary resuscitation. Circulation 77:234-239; 1988.
    • (1988) Circulation , vol.77 , pp. 234-239
    • Gudipati, C.V.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.