메뉴 건너뛰기




Volumn 2980, Issue , 1997, Pages 187-194

Enhanced biosensor performance using an avidin-biotin bridge for antibody immobilization

Author keywords

Antibody immobilization techniques; Avidin biotin; Biosensors; Fiber optics

Indexed keywords

ADSORPTION; BACTERIOLOGY; BIOSENSORS; COENZYMES; FIBER OPTICS; FIBERS; FLUORESCENCE; OPTICAL FIBERS; SIGNAL TRANSDUCTION;

EID: 0001486485     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.273534     Document Type: Conference Paper
Times cited : (11)

References (12)
  • 2
    • 85076628343 scopus 로고
    • Toxin detection using a fiber optic-based biosensor
    • R. A. Ogert, L. C. Shriver-Lake, and F. S. Ligler. "Toxin detection using a fiber optic-based biosensor," SPIE, Vol. 1885, pp. 11-17, 1993.
    • (1993) SPIE , vol.1885 , pp. 11-17
    • Ogert, R.A.1    Shriver-Lake, L.C.2    Ligler, F.S.3
  • 3
    • 0030051517 scopus 로고    scopus 로고
    • Quantitating staphylococcal enterotoxin B in diverse media using a portable fiber optic biosensor
    • L. A. Templelman, K. D. King, G. P. Anderson, and F. S. Ligler. "Quantitating staphylococcal enterotoxin B in diverse media using a portable fiber optic biosensor," Anal. Biochem., Vol. 223, pp. 50-57, 1996.
    • (1996) Anal. Biochem , vol.223 , pp. 50-57
    • Templelman, L.A.1    King, K.D.2    Anderson, G.P.3    Ligler, F.S.4
  • 4
    • 0026803262 scopus 로고
    • Detection of Clostridium botulinum toxin A using a fiber optic-based biosensor
    • R. A. Ogert, J. E. Brown, B. R. Singh, L. C. Shriver-Lake, and F. S. Ligler. "Detection of Clostridium botulinum toxin A using a fiber optic-based biosensor," Anal. Biochem., Vol. 205, pp. 306-312, 1992.
    • (1992) Anal. Biochem , vol.205 , pp. 306-312
    • Ogert, R.A.1    Brown, J.E.2    Singh, B.R.3    Shriver-Lake, L.C.4    Ligler, F.S.5
  • 5
    • 0028796386 scopus 로고
    • Detection of Yersinia pestis F1 antigen by a fiber optic biosensor
    • L. K. Cao, G. P. Anderson, F. S. Ligler, and J. Ezzell. "Detection of Yersinia pestis F1 antigen by a fiber optic biosensor," J. Clin. Micro, Vol. 33, pp. 336-341, 1995.
    • (1995) J. Clin. Micro , vol.33 , pp. 336-341
    • Cao, L.K.1    Anderson, G.P.2    Ligler, F.S.3    Ezzell, J.4
  • 8
    • 58049154463 scopus 로고    scopus 로고
    • H. H. Weetall. Immobilized enzymes, antigens, antibodies, and peptides: Preparation and characterization, Chap. 6, pp. 246-292 and chap. 8, pp. 419-497, Marcell Dekker, New York, 1975.
    • H. H. Weetall. Immobilized enzymes, antigens, antibodies, and peptides: Preparation and characterization, Chap. 6, pp. 246-292 and chap. 8, pp. 419-497, Marcell Dekker, New York, 1975.
  • 11
    • 0024596397 scopus 로고
    • Use of thiol-terminal silanes and heterobifunctional crosslinkers for immobilization of antibodies on silica surfaces
    • S. K. Bhatia, L. C. Shriver-Lake, K. J. Prior, J. H. Georger, J. M. Calvert, R. Bredehorst, and F. S. Ligler. "Use of thiol-terminal silanes and heterobifunctional crosslinkers for immobilization of antibodies on silica surfaces," Anal. Biochem., Vol. 178, pp. 408-413, 1989.
    • (1989) Anal. Biochem , vol.178 , pp. 408-413
    • Bhatia, S.K.1    Shriver-Lake, L.C.2    Prior, K.J.3    Georger, J.H.4    Calvert, J.M.5    Bredehorst, R.6    Ligler, F.S.7
  • 12
    • 0001638758 scopus 로고
    • Influence of biotin lipid surface density and accessibility on avidin binding to the tip of an optical fiber sensor
    • S. Zhao and W. M. Reichert. "Influence of biotin lipid surface density and accessibility on avidin binding to the tip of an optical fiber sensor," Langmuir, Vol. 8, pp. 2785-2791, 1992.
    • (1992) Langmuir , vol.8 , pp. 2785-2791
    • Zhao, S.1    Reichert, W.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.