메뉴 건너뛰기




Volumn 6, Issue 4, 1996, Pages 332-336

Transcatheter occlusion of arterial duct with new detachable coils

Author keywords

Arterial duct; Catheter intervention; Coil embolization; Detachable coil

Indexed keywords


EID: 0001446883     PISSN: 10479511     EISSN: None     Source Type: Journal    
DOI: 10.1017/s1047951100003978     Document Type: Article
Times cited : (14)

References (9)
  • 3
    • 0028092055 scopus 로고
    • Results of anterograde transcatheter closure of patent ductus arteriosus using single or multiple Gianturco coils
    • Hijazi ZM, Geggel RL. Results of anterograde transcatheter closure of patent ductus arteriosus using single or multiple Gianturco coils. Am J Cardiol 1994; 74: 925-929.
    • (1994) Am J Cardiol , vol.74 , pp. 925-929
    • Hijazi, Z.M.1    Geggel, R.L.2
  • 4
    • 0023153198 scopus 로고
    • Nonsurgical closure of patent ductus arteriosus: Clinical application of the Rashkind PDA Occluder System
    • Rashkind WJ, Mullins CE, Hellenbrand WE, Tait MA. Nonsurgical closure of patent ductus arteriosus: clinical application of the Rashkind PDA Occluder System. Circulaton 1987; 75: 583-592.
    • (1987) Circulaton , vol.75 , pp. 583-592
    • Rashkind, W.J.1    Mullins, C.E.2    Hellenbrand, W.E.3    Tait, M.A.4
  • 6
    • 0018839689 scopus 로고
    • A new improved coil for tapered-tip catheter for arterial occlusion
    • Chuang VP, Wallace S, Gianturco C. A new improved coil for tapered-tip catheter for arterial occlusion. Radiolgy 1980; 135: 507-509.
    • (1980) Radiolgy , vol.135 , pp. 507-509
    • Chuang, V.P.1    Wallace, S.2    Gianturco, C.3
  • 7
    • 0024558526 scopus 로고
    • Angiographic classification of the isolated, persistently patent ductus arteriosus and implication for percutaneous catheter occlusion
    • Krichenko A, Benson LN, Burrows P, Moes CAP, McLaughlin P, Freedom RM. Angiographic classification of the isolated, persistently patent ductus arteriosus and implication for percutaneous catheter occlusion. Am J Cardiol 1989; 63: 877-880.
    • (1989) Am J Cardiol , vol.63 , pp. 877-880
    • Krichenko, A.1    Benson, L.N.2    Burrows, P.3    Moes, C.A.P.4    McLaughlin, P.5    Freedom, R.M.6
  • 8
    • 0027967761 scopus 로고
    • Use of preformed nitinol snare to improve transcatheter coil delivery in occlusion of patent ductus arteriosus
    • Sommer RJ, Gutierrez A, Lai WW, Parness IA. Use of preformed nitinol snare to improve transcatheter coil delivery in occlusion of patent ductus arteriosus. Am J Cardiol 1994; 74: 836-839.
    • (1994) Am J Cardiol , vol.74 , pp. 836-839
    • Sommer, R.J.1    Gutierrez, A.2    Lai, W.W.3    Parness, I.A.4
  • 9
    • 0025750771 scopus 로고
    • Residual shunts after transcatheter closure of patent ductus arteriosus - A major concern or benign "Technomalady"?
    • Latson LA. Residual shunts after transcatheter closure of patent ductus arteriosus - a major concern or benign "Technomalady"? Circulation 1991; 84: 2591-2593.
    • (1991) Circulation , vol.84 , pp. 2591-2593
    • Latson, L.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.