메뉴 건너뛰기




Volumn 3032, Issue , 1997, Pages 513-519

Recent developments in a CdTe-based x-ray detector for digital radiography

Author keywords

2D array detector; CdTe; Radiography; Semi conductor

Indexed keywords

2D ARRAY DETECTOR; CDTE; DIGITAL RADIOGRAPHY (DR); INDIUM BUMPS; READ-OUT CIRCUIT; SEMI-CONDUCTOR; SLIT METHOD; SMALL SIZE; SPATIAL RESOLUTION (SR);

EID: 0001250216     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.274023     Document Type: Conference Paper
Times cited : (10)

References (9)
  • 4
    • 0028732557 scopus 로고
    • Preliminary characterisation of a new hybrid structure with CdTe : X-ray imaging capabilities
    • X-Ray and UV Detectors, pp
    • M. Cuzin, F. Glasser, R. Mermet, N. Meunier, O. Peyret, P. Rambaud. "Preliminary characterisation of a new hybrid structure with CdTe : X-ray imaging capabilities", SPIE, vol. 2278 X-Ray and UV Detectors, pp. 21-27, 1994
    • (1994) SPIE , vol.2278 , pp. 21-27
    • Cuzin, M.1    Glasser, F.2    Mermet, R.3    Meunier, N.4    Peyret, O.5    Rambaud, P.6
  • 5
    • 84868881367 scopus 로고
    • Caract. de détecteurs à base de tellurure de cadmium pour l'imagerie radiologique
    • Grenoble
    • N. Meunier. "Caract. de détecteurs à base de tellurure de cadmium pour l'imagerie radiologique", Thesis, Grenoble, 1994
    • (1994) Thesis
    • Meunier, N.1
  • 6
    • 0029461478 scopus 로고
    • Preliminary characterisation of a new hybrid CdTe structure for X-ray dental imaging, in Medical Imaging 1995: Phys. of Medical Imaging
    • F. Glasser, M. Cuzin, O. Peyret, F. Mongellaz, P. Rambaud, M. Ravetto, B. Pitault, A. Salaville, S. Paltrier. "Preliminary characterisation of a new hybrid CdTe structure for X-ray dental imaging", in Medical Imaging 1995: Phys. of Medical Imaging, Proc. SPIE 2432, pp 442-453, 1995
    • (1995) Proc. SPIE , vol.2432 , pp. 442-453
    • Glasser, F.1    Cuzin, M.2    Peyret, O.3    Mongellaz, F.4    Rambaud, P.5    Ravetto, M.6    Pitault, B.7    Salaville, A.8    Paltrier, S.9
  • 8
    • 84868867968 scopus 로고    scopus 로고
    • Caracterisation d'un détecteur pixellisé de rayonnement X pour différentes applications
    • B. Bosset, "Caracterisation d'un détecteur pixellisé de rayonnement X pour différentes applications", internal report, 1996
    • (1996) internal report
    • Bosset, B.1
  • 9
    • 84868877536 scopus 로고    scopus 로고
    • Konstantinos Spartiotis, Risto Orava, Agamemnon Epenetos, Tom schulman, Jouni Pyyhtiä, Tieliang. Cao, Miltiadis Sarakinos, Ilkka Suni, Jaakko Salonen, Zaheed Karim, David Allison, Bal Sanghera, Melvyn Myers and Panu Jalas, A novel semiconductor pixel device and system for X-ray and gamma ray imaging, IEEE Nuclear-Science Symposium&Medical Imaging, 1996
    • Konstantinos Spartiotis, Risto Orava, Agamemnon Epenetos, Tom schulman, Jouni Pyyhtiä, Tieliang. Cao, Miltiadis Sarakinos, Ilkka Suni, Jaakko Salonen, Zaheed Karim, David Allison, Bal Sanghera, Melvyn Myers and Panu Jalas, "A novel semiconductor pixel device and system for X-ray and gamma ray imaging", IEEE Nuclear-Science Symposium&Medical Imaging, 1996


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.