메뉴 건너뛰기




Volumn 33, Issue 1, 1986, Pages 550-555

Event localization in a continuous scintillation detector using digital processing

Author keywords

[No Author keywords available]

Indexed keywords


EID: 0001181001     PISSN: 00189499     EISSN: 15581578     Source Type: Journal    
DOI: 10.1109/TNS.1986.4337163     Document Type: Article
Times cited : (51)

References (17)
  • 1
    • 84920998524 scopus 로고    scopus 로고
    • Karp JS: A positron camera using position-sensitive detectors: PENN-PET. (in press)
    • Muehllehner G, Karp JS: A positron camera using position-sensitive detectors: PENN-PET. J Nucl Med (in press).
    • J Nucl Med
    • Muehllehner, G.1
  • 2
    • 0021830446 scopus 로고
    • Performance of a position-sensitive scintillation detector
    • Karp JS, Muehllehner G: Performance of a position-sensitive scintillation detector. Phys Med Biol 30:643-655, 1985.
    • (1985) Phys Med Biol , vol.30 , pp. 643-655
    • Karp, J.S.1    Muehllehner, G.2
  • 3
    • 84939007911 scopus 로고    scopus 로고
    • A method for reconstructing images from data obtained with a hexagonal bar positron camera. (in press)
    • Muehllehner G, Karp JS, Guvenis A: A method for reconstructing images from data obtained with a hexagonal bar positron camera. IEEE, Trans Medical Imaging (in press).
    • IEEE, Trans Medical Imaging
    • Muehllehner, G.1    Karp, J.S.2    Guvenis, A.3
  • 4
    • 0021374888 scopus 로고
    • One- and two-dimensional position sensitive scintillation detectors for thermal neutrons
    • Kurz R, Naday I, Schelten J: One- and two-dimensional position sensitive scintillation detectors for thermal neutrons. IEEE, NS-32:453-456, 1985.
    • (1985) IEEE , vol.NS-32 , pp. 453-456
    • Kurz, R.1    Naday, I.2    Schelten, J.3
  • 5
    • 0019470324 scopus 로고
    • Digital scintigrapy: principles, design and performance
    • Genna S, Pang S, Smith A: Digital scintigrapy: principles, design and performance. J Nucl Med 22:365-371, 1981.
    • (1981) J Nucl Med , vol.22 , pp. 365-371
    • Genna, S.1    Pang, S.2    Smith, A.3
  • 6
    • 0012922026 scopus 로고
    • Shortening of detector signals with passive filters for pile-up reduction
    • Amsel G, Bosshard R, Zajde C: Shortening of detector signals with passive filters for pile-up reduction. Nucl Instr Meth 71:1-12, 1969.
    • (1969) Nucl Instr Meth , vol.71 , pp. 1-12
    • Amsel, G.1    Bosshard, R.2    Zajde, C.3
  • 7
    • 84908720720 scopus 로고
    • Performance parameters of a positron imaging camera
    • Muehllehner G, Buchin MP, Dudek JH: Performance parameters of a positron imaging camera. IEEE, NS-23:528-537, 1976.
    • (1976) IEEE , vol.NS-23 , pp. 528-537
    • Muehllehner, G.1    Buchin, M.P.2    Dudek, J.H.3
  • 8
    • 13744265648 scopus 로고
    • Variable sampling-time technique for improved count rate performance of scintillation detectors
    • Tanaka E, Nohara N, Murayama H: Variable sampling-time technique for improved count rate performance of scintillation detectors. Nucl Instr Meth 158:459-466, 1979.
    • (1979) Nucl Instr Meth , vol.158 , pp. 459-466
    • Tanaka, E.1    Nohara, N.2    Murayama, H.3
  • 9
    • 0021370468 scopus 로고
    • Design consideration of small crystal positron camera systems
    • Kesselberg M, Bohm C, Litton JE et al: Design consideration of small crystal positron camera systems. IEEE, NS-32, 907–911, 1985.
    • (1985) IEEE , vol.NS-32 , pp. 907-911
    • Kesselberg, M.1    Bohm, C.2    Litton, J.E.3
  • 11
    • 0000233531 scopus 로고
    • Sensitivity, resolution and linearity of the scintillation camera
    • Anger HO: Sensitivity, resolution and linearity of the scintillation camera. IEEE, NS-13:380-392, 1966.
    • (1966) IEEE , vol.NS-13 , pp. 380-392
    • Anger, H.O.1
  • 12
    • 0015292225 scopus 로고
    • Improved resolution of the Anger scintillation camera through the use of threshold preamplifiers
    • Kulberg GH, van Dijk N, Muehllehner G: Improved resolution of the Anger scintillation camera through the use of threshold preamplifiers. J Nuci Med 13:169-171, 1972.
    • (1972) J Nuci Med , vol.13 , pp. 169-171
    • Kulberg, G.H.1    van Dijk, N.2    Muehllehner, G.3
  • 13
    • 0016922847 scopus 로고
    • Maximum a posteriori estimation of position in scintillation cameras
    • Gray RM and Macovski A: Maximum a posteriori estimation of position in scintillation cameras. IEEE Trans Nucl Sci 23:849-852, 1976.
    • (1976) IEEE Trans Nucl Sci , vol.23 , pp. 849-852
    • Gray, R.M.1    Macovski, A.2
  • 14
    • 0018984993 scopus 로고
    • One dimensional scintillation cameras for positron ECT ring detectors
    • Burnham C, Bradshaw J, Kaufman D et al: One dimensional scintillation cameras for positron ECT ring detectors. IEEE, Trans Nucl Sci 28:109-113, 1981.
    • (1981) IEEE, Trans Nucl Sci , vol.28 , pp. 109-113
    • Burnham, C.1    Bradshaw, J.2    Kaufman, D.3
  • 15
    • 0021376863 scopus 로고
    • Digital position estimation for the modular scintillation camera
    • Milster TD, Selberg LA, Barrett HH et al: Digital position estimation for the modular scintillation camera. IEEE Trans Nucl Sci 32:748-752, 1985.
    • (1985) IEEE Trans Nucl Sci. , vol.32 , pp. 748-752
    • Milster, T.D.1    Selberg, L.A.2    Barrett, H.H.3
  • 16
    • 0018436018 scopus 로고
    • Use of position sensitive detectors in positron imaging
    • MUehllehner G, Colsher JG: Use of position sensitive detectors in positron imaging. IEEE, NS-27:569-571, 1980.
    • (1980) IEEE , vol.NS-27 , pp. 569-571
    • Muehllehner, G.1    Colsher, J.G.2
  • 17
    • 0021375227 scopus 로고
    • A single chip pulse processor for nuclear spectroscopy
    • Hilsenrath F, Voss HD, Bakke JC: A single chip pulse processor for nuclear spectroscopy. IEEE, NS-32:145-149, 1985.
    • (1985) IEEE , vol.NS-32 , pp. 145-149
    • Hilsenrath, F.1    Voss, H.D.2    Bakke, J.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.