Volumn 20, Issue 5, 1998, Pages 313-319

Influence of voltage transformers on operating conditions of ground-fault protection system for unit-connected generator

Author keywords

Generator; Ground fault; Voltage transformer

Indexed keywords


EID: 0001163901     PISSN: 01420615     EISSN: None     Source Type: Journal    
DOI: 10.1016/s0142-0615(98)00012-x     Document Type: Article
Times cited : (14)

References (14)
  • 2
    • 0021408203 scopus 로고
    • A comparison of 100% stator ground fault protection schemes for generator stator windings
    • Pope, J. W., A comparison of 100% stator ground fault protection schemes for generator stator windings. IEEE Transactions on Power Apparatus and Systems, PAS, 1984, 103(4), 832-840.
    • (1984) IEEE Transactions on Power Apparatus and Systems, PAS , vol.103 , Issue.4 , pp. 832-840
    • Pope, J.W.1
  • 3
    • 0025409174 scopus 로고
    • Adaptive ground fault protection schemes for turbogenerators based on third harmonic voltages
    • Yin, X. G., Malik, O., Hope, G. and Chen, D., Adaptive ground fault protection schemes for turbogenerators based on third harmonic voltages. IEEE Transactions on Power Delivery, 1990, 5(2), 595-603.
    • (1990) IEEE Transactions on Power Delivery , vol.5 , Issue.2 , pp. 595-603
    • Yin, X.G.1    Malik, O.2    Hope, G.3    Chen, D.4
  • 7
    • 0027266708 scopus 로고
    • Optimum settings for the 100% ground stator protection in the Tucurui, Balbina and Samuel hydro power plants-Elektronorte-Brazil
    • York, UK
    • Soares de Oliveira, A. J., Optimum settings for the 100% ground stator protection in the Tucurui, Balbina and Samuel hydro power plants-Elektronorte-Brazil. In Fifth International Conference on Developments in Power System Protection, York, UK, 1993, pp. 186-190.
    • (1993) Fifth International Conference on Developments in Power System Protection , pp. 186-190
    • Soares De Oliveira, A.J.1
  • 9
    • 0042117638 scopus 로고    scopus 로고
    • Influence of load on 3rd harmonic voltage in circuits of ground-fault protections of unit-connected generators
    • Gdańsk, Poland
    • Zielichowski, M. and Fulczyk, M., Influence of load on 3rd harmonic voltage in circuits of ground-fault protections of unit-connected generators. In Proceedings of the International Symposium APE'97, Gdańsk, Poland, 1997, pp. 223-230.
    • (1997) Proceedings of the International Symposium APE'97 , pp. 223-230
    • Zielichowski, M.1    Fulczyk, M.2
  • 11
    • 0019098054 scopus 로고
    • Erosion du circuit magnetique des stators de turbogenerateurs pendant les courts-circuits a la terre
    • Zielichowski, M., Erosion du circuit magnetique des stators de turbogenerateurs pendant les courts-circuits a la terre. Revue Electricite, 1980, IX(12), 226-234.
    • (1980) Revue Electricite , vol.9 , Issue.12 , pp. 226-234
    • Zielichowski, M.1
  • 12
    • 0043119524 scopus 로고
    • Earth-fault processes in the stators of the unit-connected turbogenerators
    • Scientific Papers of the Institute of Electrical Power Engineering of the Technical University of Wroclaw, No. 78
    • Zielichowski, M., Earth-fault processes in the stators of the unit-connected turbogenerators. Scientific Papers of the Institute of Electrical Power Engineering of the Technical University of Wroclaw, No. 78, Monographs No. 20, 1988.
    • (1988) Monographs , vol.20
    • Zielichowski, M.1
  • 14
    • 0041616752 scopus 로고    scopus 로고
    • Third harmonic ground fault protection schemes for generator stator windings
    • Nanyang Technology University, Singapore
    • Zielichowski, M. and Fulczyk, M., Third harmonic ground fault protection schemes for generator stator windings. In Proceedings of the International Power Engineering Conference IPEC'97, Nanyang Technology University, Singapore, 1997, pp. 587-592.*.
    • (1997) Proceedings of the International Power Engineering Conference IPEC'97 , pp. 587-592
    • Zielichowski, M.1    Fulczyk, M.2