메뉴 건너뛰기




Volumn 1, Issue 5, 1997, Pages 285-294

Detection of methyl isocyanate in air with the use of hand-held ion mobility spectrometers

Author keywords

Chemical agent monitor; Hand held detectors; Ion mobility spectrometry; Ion mobility spectrometry mass spectrometry mass spectrometry; Methyl isocyanate

Indexed keywords


EID: 0000820532     PISSN: 1086900X     EISSN: None     Source Type: Journal    
DOI: 10.1002/(sici)1520-6521(1997)1:5<285::aid-fact4>3.0.co;2-t     Document Type: Article
Times cited : (7)

References (14)
  • 3
    • 20544432294 scopus 로고
    • NIOSH (National Institute for Occupational Safety and Health, U.S. Department of Health and Human Services) Pocket Guide to Chemical Hazards, DHHS (NIOSH) Publication No. 85-114, 1987.
    • (1987) DHHS (NIOSH) Publication No. 85-114 , vol.85 , Issue.114
  • 5
    • 80051751860 scopus 로고
    • Ion mobility spectrometry in analytical chemistry
    • H. H. Hill, Jr. and R. H. St. Louis, "Ion Mobility Spectrometry in Analytical Chemistry," Crit. Rev. Anal. Chem. 21, 321-355, (1990).
    • (1990) Crit. Rev. Anal. Chem. , vol.21 , pp. 321-355
    • Hill Jr., H.H.1    St Louis, R.H.2
  • 6
    • 84963444786 scopus 로고
    • Advances in ion mobility spectrometry: 19801990
    • G. A. Eiceman, "Advances in Ion Mobility Spectrometry: 19801990," Crit. Rev. Anal. Chem. 22, 17-36, (1991).
    • (1991) Crit. Rev. Anal. Chem. , vol.22 , pp. 17-36
    • Eiceman, G.A.1
  • 8
    • 2442420217 scopus 로고
    • Unambiguous identification of IMS responses by IMS/MS/MS - Development of realistic standards for ion mobility determinations
    • Cambridge, England, August
    • D. B. Shoff and C. S. Harden, "Unambiguous Identification of IMS Responses by IMS/MS/MS - Development of Realistic Standards for Ion Mobility Determinations," in Proceedings of the Fourth International Workshop on Ion Mobility Spectrometry, Cambridge, England, August 1995.
    • (1995) Proceedings of the Fourth International Workshop on Ion Mobility Spectrometry
    • Shoff, D.B.1    Harden, C.S.2
  • 9
    • 0028914261 scopus 로고
    • Enhanced selectivity in ion mobility spectrometry analysis of complex mixtures by alternate reagent gas chemistry
    • G. A. Eiceman, Y-F. Wang, L. Garcia-Gonzalez, C. S. Harden and D. B. Shoff, "Enhanced Selectivity in Ion Mobility Spectrometry Analysis of Complex Mixtures by Alternate Reagent Gas Chemistry," Anal. Chim. Acta 306, 21-33, (1995).
    • (1995) Anal. Chim. Acta , vol.306 , pp. 21-33
    • Eiceman, G.A.1    Wang, Y.-F.2    Garcia-Gonzalez, L.3    Harden, C.S.4    Shoff, D.B.5
  • 10
    • 0000577073 scopus 로고
    • Ion mobility spectrometry of aliphatic and aromatic amines
    • Z. Karpas, "Ion Mobility Spectrometry of Aliphatic and Aromatic Amines," Anal. Chem. 61, 684-689, (1989).
    • (1989) Anal. Chem. , vol.61 , pp. 684-689
    • Karpas, Z.1
  • 12
    • 0003601534 scopus 로고    scopus 로고
    • Merck & Co., Inc., Whitehouse, NJ
    • The Merck Index (12th Edition), Merck & Co., Inc., Whitehouse, NJ, 1996 p. 1039.
    • (1996) The Merck Index (12th Edition) , pp. 1039
  • 13
    • 20544471217 scopus 로고    scopus 로고
    • Graseby Dynamics, Ltd., Park Avenue, Bushey, Watford, Herts., WD2 2BW, United Kingdom, private communication
    • A. H. Brittain, Graseby Dynamics, Ltd., Park Avenue, Bushey, Watford, Herts., WD2 2BW, United Kingdom, private communication, 1996.
    • (1996)
    • Brittain, A.H.1
  • 14
    • 20544435032 scopus 로고    scopus 로고
    • Geo-Centers, Inc., Gunpowder Branch, Aberdeen Proving Ground, MD 21010, private communication
    • R. G. Ewing, Geo-Centers, Inc., Gunpowder Branch, Aberdeen Proving Ground, MD 21010, private communication, 1996. Thirty-five proton bound mixed dimer ions (70 compounds) were studied. Standard deviation of measured drift times of the proton bound mixed dimer ions from the arithmetic mean of the drift times of the corresponding pure proton bound dimer ions was 0.63%.
    • (1996)
    • Ewing, R.G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.