메뉴 건너뛰기




Volumn 101, Issue 2, 1996, Pages 133-140

The NIST high accuracy scale for absolute spectral response from 406 nm to 920 nm

Author keywords

Absolute spectral response; Cryogenic radiometer; Light trapping detectors; Measurements; Optical power; Quality system; Quantum efficiency; Scale; Silicon photodiode

Indexed keywords


EID: 0000580494     PISSN: 1044677X     EISSN: None     Source Type: Journal    
DOI: 10.6028/jres.101.015     Document Type: Article
Times cited : (53)

References (31)
  • 2
    • 6144220786 scopus 로고    scopus 로고
    • Realization of a scale of absolute spectral response using the NIST high accuracy cryogenic radiometer
    • submitted to
    • T. R. Gentile, J. M. Houston, and C. L. Cromer, Realization of a scale of absolute spectral response using the NIST high accuracy cryogenic radiometer, submitted to Applied Optics.
    • Applied Optics
    • Gentile, T.R.1    Houston, J.M.2    Cromer, C.L.3
  • 4
    • 5844315448 scopus 로고
    • Publ. 64 Commission Internationale de L'Éclairage, Paris, Currently available through the U.S. National Committee of the CIE, c/o Mr. Thomas M. Lemons, TLA-Lighting Consultants, Inc., 72 Loring Avenue, Salem, MA 01970
    • Determination of the Spectral Responsivity of Optical Radiation Detectors, Publ. 64 (Commission Internationale de L'Éclairage, Paris, 1984). (Currently available through the U.S. National Committee of the CIE, c/o Mr. Thomas M. Lemons, TLA-Lighting Consultants, Inc., 72 Loring Avenue, Salem, MA 01970.)
    • (1984) Determination of the Spectral Responsivity of Optical Radiation Detectors
  • 6
    • 0015680038 scopus 로고
    • Comparison of the laser power and total irradiance scales maintained by the National Bureau of Standards
    • J. Geist, L. B. Schmidt, and W. E. Case, Comparison of the laser power and total irradiance scales maintained by the National Bureau of Standards, Appl. Opt. 12, 2773-2776 (1973).
    • (1973) Appl. Opt. , vol.12 , pp. 2773-2776
    • Geist, J.1    Schmidt, L.B.2    Case, W.E.3
  • 8
    • 0003492093 scopus 로고
    • The present study follows, to the extent possible, International Organization for Standardization, Geneva, Switzerland
    • The present study follows, to the extent possible, the ISO Guide to the Expression of Uncertainty in Measurement (International Organization for Standardization, Geneva, Switzerland, 1993). Since 1994, the NIST policy has been to conform to the Guide in reporting its activities, using an expanded uncertainty coverage factor (as defined in the Guide) of k = 2. See also B. N. Taylor and C. E. Kuyatt, Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results, Natl. Inst. Stand. Technol. Tech. Note 1297 (1994 ed.).
    • (1993) ISO Guide to the Expression of Uncertainty in Measurement
  • 9
    • 0003513083 scopus 로고
    • Natl. Inst. Stand. Technol. Tech. Note 1297 ed.
    • The present study follows, to the extent possible, the ISO Guide to the Expression of Uncertainty in Measurement (International Organization for Standardization, Geneva, Switzerland, 1993). Since 1994, the NIST policy has been to conform to the Guide in reporting its activities, using an expanded uncertainty coverage factor (as defined in the Guide) of k = 2. See also B. N. Taylor and C. E. Kuyatt, Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results, Natl. Inst. Stand. Technol. Tech. Note 1297 (1994 ed.).
    • (1994) Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results
    • Taylor, B.N.1    Kuyatt, C.E.2
  • 10
    • 5844306405 scopus 로고    scopus 로고
    • note
    • Unpublished preprint of sequel to NBS Technical Note 950 describing the radiometric characteristics of the DRTIP radiometers, p. 9.
  • 11
    • 0020813630 scopus 로고
    • Silicon photodiode device with 100 % external quantum efficiency
    • E. F. Zalewski and C. R. Duda, Silicon photodiode device with 100 % external quantum efficiency, Appl. Opt. 22, 2867-2873 (1983).
    • (1983) Appl. Opt. , vol.22 , pp. 2867-2873
    • Zalewski, E.F.1    Duda, C.R.2
  • 12
    • 5844230913 scopus 로고    scopus 로고
    • The QED-200 is now manufactured by Graseby Optronics, Orlando, FL
    • The QED-200 is now manufactured by Graseby Optronics, Orlando, FL.
  • 14
    • 0024908235 scopus 로고
    • Photodetector spectral response based on 100 % quantum efficient detectors
    • Optical Radiation Measurements II, James M. Palmer, ed.
    • J. M. Houston and E. F. Zalewski, Photodetector spectral response based on 100 % quantum efficient detectors, Optical Radiation Measurements II, James M. Palmer, ed., Proc. SPIE 1109, 268-277 (1989).
    • (1989) Proc. SPIE 1109 , pp. 268-277
    • Houston, J.M.1    Zalewski, E.F.2
  • 15
    • 5544257421 scopus 로고
    • A new spectral response calibration method using a silicon photodiode trap detector
    • Anaheim, CA, Jan. 31-Feb. 1
    • C. L. Cromer, A new spectral response calibration method using a silicon photodiode trap detector, presented at the 1991 Measurement Science Conference, Anaheim, CA, Jan. 31-Feb. 1, 1991.
    • (1991) 1991 Measurement Science Conference
    • Cromer, C.L.1
  • 16
    • 0026224347 scopus 로고
    • Trap detectors and their properties
    • N. P. Fox, Trap detectors and their properties, Metrologia 28, 197-202 (1991).
    • (1991) Metrologia , vol.28 , pp. 197-202
    • Fox, N.P.1
  • 17
    • 0024939877 scopus 로고
    • Current status of, and future directions in, silicon photodiode self-calibration
    • Optical Radiation Measurements II, James M. Palmer, Editor
    • J. Geist, Current status of, and future directions in, silicon photodiode self-calibration, Optical Radiation Measurements II, James M. Palmer, Editor, Proc. SPIE 1109, 246-256 (1989).
    • (1989) Proc. SPIE 1109 , pp. 246-256
    • Geist, J.1
  • 18
    • 0026223990 scopus 로고
    • Comparison between cryogenic radiometry and the predicted quantum efficiency of pn silicon photodiode light traps
    • E. F. Zalewski and C. C. Hoyt, Comparison between cryogenic radiometry and the predicted quantum efficiency of pn silicon photodiode light traps, Metrologia 28, 203-206 (1991).
    • (1991) Metrologia , vol.28 , pp. 203-206
    • Zalewski, E.F.1    Hoyt, C.C.2
  • 19
    • 0022111159 scopus 로고
    • A cryogenic radiometer for absolute radiometric measurements
    • J. E. Martin, N. P. Fox, and P. J. Key, A cryogenic radiometer for absolute radiometric measurements, Metrologia 21, 147-155 (1985).
    • (1985) Metrologia , vol.21 , pp. 147-155
    • Martin, J.E.1    Fox, N.P.2    Key, P.J.3
  • 20
    • 36149036258 scopus 로고
    • Characterization of photodiodes in the UV and visible spectral region based on cryogenic radiometry
    • F. Lei and J. Fischer, Characterization of photodiodes in the UV and visible spectral region based on cryogenic radiometry, Metrologia 30, 297-303 (1993).
    • (1993) Metrologia , vol.30 , pp. 297-303
    • Lei, F.1    Fischer, J.2
  • 22
    • 0026224541 scopus 로고
    • Astigmatism cancellation in spectroradiometry
    • J. L. Gardner, Astigmatism cancellation in spectroradiometry, Metrologia 28, 251-254 (1991).
    • (1991) Metrologia , vol.28 , pp. 251-254
    • Gardner, J.L.1
  • 23
    • 84975634955 scopus 로고
    • Fourteen-decade photocurrent measurements with large-area silicon photodiodes at room temperature
    • G. Eppeldauer and J. E. Hardis, Fourteen-decade photocurrent measurements with large-area silicon photodiodes at room temperature, Appl. Opt. 30, 3091-3099 (1991).
    • (1991) Appl. Opt. , vol.30 , pp. 3091-3099
    • Eppeldauer, G.1    Hardis, J.E.2
  • 26
    • 5544302965 scopus 로고
    • Apparatus function of a prism-grating double monochromator
    • R. D. Saunders and J. B. Shumaker, Apparatus function of a prism-grating double monochromator, Appl. Opt. 25, 3710-3714 (1986).
    • (1986) Appl. Opt. , vol.25 , pp. 3710-3714
    • Saunders, R.D.1    Shumaker, J.B.2
  • 27
    • 0343376754 scopus 로고
    • Comparison of the NIST high accuracy cryogenic radiometer and the NIST scale of detector spectral response
    • J. M. Houston, C. L. Cromer, J. E. Hardis, and T. C. Larason, Comparison of the NIST high accuracy cryogenic radiometer and the NIST scale of detector spectral response, Metrologia 30, 285-290 (1993).
    • (1993) Metrologia , vol.30 , pp. 285-290
    • Houston, J.M.1    Cromer, C.L.2    Hardis, J.E.3    Larason, T.C.4
  • 28
    • 5844302215 scopus 로고
    • The radiometric physics division's efforts at building a quality system based on ISO/IEC Guide 25
    • Acapulco, Mexico May 10-13
    • T. C. Larason, The radiometric physics division's efforts at building a quality system based on ISO/IEC Guide 25, presented at the Asociacion Mexicana De Metrologia, A. C. 1994 Conference, Acapulco, Mexico May 10-13, 1994.
    • (1994) Asociacion Mexicana de Metrologia, A. C. 1994 Conference
    • Larason, T.C.1
  • 29
    • 5844238683 scopus 로고
    • Building a quality system based on ANSI/NCSL Z540-1-1994-an effort by the Radiometric Physics Division at NIST
    • National Conference of Standards Laboratories, Dallas, TX, July 16-20
    • S. S. Bruce and T. C. Larason, Building a quality system based on ANSI/NCSL Z540-1-1994-an effort by the Radiometric Physics Division at NIST, Proc. NCSL 1995 Workshop and Symposium (National Conference of Standards Laboratories), Dallas, TX, July 16-20, 1995, pp. 631-643.
    • (1995) Proc. NCSL 1995 Workshop and Symposium , pp. 631-643
    • Bruce, S.S.1    Larason, T.C.2
  • 30
    • 0006016966 scopus 로고
    • Characterization of a high sensitivity composite silicon bolometer
    • G. Eppeldauer, A. L. Migdall, and C. L. Cromer, Characterization of a high sensitivity composite silicon bolometer, Metrologia 30, 317-320 (1993).
    • (1993) Metrologia , vol.30 , pp. 317-320
    • Eppeldauer, G.1    Migdall, A.L.2    Cromer, C.L.3
  • 31
    • 0346805403 scopus 로고
    • A cryogenic silicon resistance bolometer for use as an infrared transfer standard detector
    • edited by M. Kaviany et al., ASME, New York, NY
    • G. Eppeldauer, A. L. Migdall, and C. L. Cromer, A cryogenic silicon resistance bolometer for use as an infrared transfer standard detector, Thermal Phenomena at Molecular and Microscales and in Cryogenic Infrared Detectors, edited by M. Kaviany et al., (ASME HTD-Vol. 277, New York, NY (1994) pp. 63-67.
    • (1994) Thermal Phenomena at Molecular and Microscales and in Cryogenic Infrared Detectors , vol.277 HTD-VOL , pp. 63-67
    • Eppeldauer, G.1    Migdall, A.L.2    Cromer, C.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.