Volumn 5, Issue 2, 1996, Pages 112-125

Asessment of non-smokers' exposure to environmental tobacco smoke using personal-exposure and fixed-location monitoring

Author keywords

Environmental tobacco smoke; Fixed location monitoring; HVAC assessment; Personal monitoring

Indexed keywords

NICOTIANA TABACUM;

EID: 0000562215     PISSN: 1420326X     EISSN: None     Source Type: Journal    
DOI: 10.1159/000463695     Document Type: Article
Times cited : (23)

References (39)
  • 1
    • 0025340809 scopus 로고
    • The origins and properties of environmental tobacco smoke
    • Baker RR, Proctor CJ: The origins and properties of environmental tobacco smoke. Environ Int 1990;16:231-245.
    • (1990) Environ Int , vol.16 , pp. 231-245
    • Baker, R.R.1    Proctor, C.J.2
  • 7
    • 0027418776 scopus 로고
    • Indoor air quality and environmental tobacco smoke: Concentration and exposure
    • Holcomb LC: Indoor air quality and environmental tobacco smoke: Concentration and exposure. Environ Int 1993;19:9-40.
    • (1993) Environ Int , vol.19 , pp. 9-40
    • Holcomb, L.C.1
  • 8
    • 2742536173 scopus 로고
    • Standard D4532-92 - Standard test method for respirable dust in workplace atmospheres. 1993
    • Philadelphia, American Society for Testing and Materials, vol 11.03
    • ASTM: Standard D4532-92 - Standard test method for respirable dust in workplace atmospheres. 1993 Annual Book of ASTM Standards. Philadelphia, American Society for Testing and Materials, 1993, vol 11.03, pp 311-315.
    • (1993) Annual Book of ASTM Standards , pp. 311-315
  • 9
    • 0025375865 scopus 로고
    • Method for assessing the contribution of environmental tobacco smoke to respirable suspended particles in indoor environments
    • Conner JM, Oldaker GB, Murphy JJ: Method for assessing the contribution of environmental tobacco smoke to respirable suspended particles in indoor environments. Environ Technol 1990;11:189-196.
    • (1990) Environ Technol , vol.11 , pp. 189-196
    • Conner, J.M.1    Oldaker, G.B.2    Murphy, J.J.3
  • 10
    • 0024731146 scopus 로고
    • Collection and Determination of Solanesol as a Tracer of Environmental Tobacco Smoke in Indoor Air
    • Ogden MW, Maiolo KC: Collection and Determination of Solanesol as a Tracer of Environmental Tobacco Smoke in Indoor Air. Environ Sci Technol 1989;23:1148-1154.
    • (1989) Environ Sci Technol , vol.23 , pp. 1148-1154
    • Ogden, M.W.1    Maiolo, K.C.2
  • 11
    • 2742584412 scopus 로고
    • Standard D 5075-90 - Standard test method for nicotine in indoor air. 1993
    • Philadelphia, American Society for Testing and Materials, vol 11.03
    • ASTM: Standard D 5075-90 - Standard test method for nicotine in indoor air. 1993 Annual Book of ASTM Standards. Philadelphia, American Society for Testing and Materials, 1993, vol 11.03, pp 423-429.
    • (1993) Annual Book of ASTM Standards , pp. 423-429
  • 12
    • 0011489749 scopus 로고
    • Environmental tobacco smoke monitoring with an atmospheric pressure chemical ionization mass spectrometer/mass spectrometer coupled to a test chamber
    • Pittsburgh, paper 86-37.6
    • Thome FA, Heavner DL, Ingebrethsen BJ: Environmental tobacco smoke monitoring with an atmospheric pressure chemical ionization mass spectrometer/mass spectrometer coupled to a test chamber. Proceedings 79th Annual Meeting of the Air Pollution Control Association, Pittsburgh, 1986, paper 86-37.6.
    • (1986) Proceedings 79th Annual Meeting of the Air Pollution Control Association
    • Thome, F.A.1    Heavner, D.L.2    Ingebrethsen, B.J.3
  • 14
    • 0003218837 scopus 로고
    • Use of capillary chromatography in the analysis of environmental tobacco smoke
    • Jennings W, Nikelly JG (eds): Heidelberg, Huthig
    • Ogden MW: Use of capillary chromatography in the analysis of environmental tobacco smoke; in Jennings W, Nikelly JG (eds): Capillary Chromatography - The Applications. Heidelberg, Huthig, 1991, pp 67-82.
    • (1991) Capillary Chromatography - the Applications , pp. 67-82
    • Ogden, M.W.1
  • 15
    • 2842555963 scopus 로고
    • Standard D4597-92 - Standard practice for sampling workplace atmospheres to collect organic gases or vapours with activated charcoal diffusional samplers. 1993
    • Philadelphia, American Society for Testing and Materials, vol 11.03
    • ASTM: Standard D4597-92 - Standard practice for sampling workplace atmospheres to collect organic gases or vapours with activated charcoal diffusional samplers. 1993 Annual Book of ASTM Standards. Philadelphia, American Society for Testing and Materials, 1993, vol 11.03, pp 327-330.
    • (1993) Annual Book of ASTM Standards , pp. 327-330
  • 16
    • 2842582661 scopus 로고
    • Standard D3687-89 - Standard practice for analysis of organic compound vapours collected by the activated charcoal tube adsorption method
    • Philadelphia, American Society for Testing and Materials, vol 11.03
    • ASTM: Standard D3687-89 - Standard practice for analysis of organic compound vapours collected by the activated charcoal tube adsorption method. 1993 Annual Book of ASTM Standards. Philadelphia, American Society for Testing and Materials, 1993, vol 11.03, pp 207-212.
    • (1993) 1993 Annual Book of ASTM Standards , pp. 207-212
  • 17
    • 0023577656 scopus 로고
    • Salivary cotinine levels and involuntary tobacco exposure in children and adults in New Mexico
    • Coultas DB, Howard CA, Peake GT, Skipper BJ, Samet JM: Salivary cotinine levels and involuntary tobacco exposure in children and adults in New Mexico. Am Rev Respir Dis 1987;136:305-309.
    • (1987) Am Rev Respir Dis , vol.136 , pp. 305-309
    • Coultas, D.B.1    Howard, C.A.2    Peake, G.T.3    Skipper, B.J.4    Samet, J.M.5
  • 18
  • 20
    • 0019076452 scopus 로고
    • Rapid gas-liquid chromatographic determination of cotinine in biological fluids
    • Feyerabend C, Russel MAH: Rapid gas-liquid chromatographic determination of cotinine in biological fluids. Analyst 1980;105:998-1001.
    • (1980) Analyst , vol.105 , pp. 998-1001
    • Feyerabend, C.1    Russel, M.A.H.2
  • 21
  • 22
    • 2842555964 scopus 로고
    • Standard D3686-89 - Standard practice for sampling atmospheres to collect organic compound vapours (activated charcoal tube adsorption method)
    • Philadelphia, American Society for Testing and Materials, vol 11.03
    • ASTM: Standard D3686-89 - Standard practice for sampling atmospheres to collect organic compound vapours (activated charcoal tube adsorption method). 1993 Annual Book of ASTM Standards. Philadelphia, American Society for Testing and Materials, 1993, vol 11.03, pp 200-206.
    • (1993) 1993 Annual Book of ASTM Standards , pp. 200-206
  • 23
    • 0003427027 scopus 로고
    • American Society of Heating, Refrigerating and Air Conditioning Engineers, Inc., and American National Standards Institute, Atlanta
    • ASHRAE/ANSI: Ventilation for Acceptable Indoor Air Quality. ASHRAE/ANSI Standard 62-1989. American Society of Heating, Refrigerating and Air Conditioning Engineers, Inc., and American National Standards Institute, Atlanta, 1989.
    • (1989) Ventilation for Acceptable Indoor Air Quality. ASHRAE/ANSI Standard 62-1989
  • 24
    • 2842544892 scopus 로고
    • Written Statement of the American Society of Heating, Refrigerating, and Air-Conditioning Engineers. Agriculture Research and Environment, May 9
    • ASHRAE: Written Statement of the American Society of Heating, Refrigerating, and Air-Conditioning Engineers. Presented to the US Congressional, The Science, Space and Technol Subcommittee on Natural Resources, Agriculture Research and Environment, May 9, 1991.
    • (1991) US Congressional, the Science, Space and Technol Subcommittee on Natural Resources
  • 26
    • 0000527173 scopus 로고
    • Evaluation of methods for estimating the contribution of ETS to respirable suspended particles
    • International Conference on Indoor Air Quality and Climate, Ottawa in Walkinshaw DS (ed)
    • Ogden MW, Maiolo KC, Oldaker GB III, Conrad FW Jr: Evaluation of methods for estimating the contribution of ETS to respirable suspended particles. International Conference on Indoor Air Quality and Climate, Ottawa 1990; in Walkinshaw DS (ed): Indoor Air 90, vol 2, pp 415-420.
    • (1990) Indoor Air 90 , vol.2 , pp. 415-420
    • Ogden, M.W.1    Maiolo, K.C.2    Oldaker III, G.B.3    Conrad Jr., F.W.4
  • 27
    • 2842550475 scopus 로고
    • Respiratory particle burden on exposure to environmental tobacco smoke
    • Sixth International Conference on Indoor Air Quality and Climate
    • Scherer G, Ruppert T, Draube H, Tricker AR, Adlkofer F: Respiratory particle burden on exposure to environmental tobacco smoke. Sixth International Conference on Indoor Air Quality and Climate, 1993; in Indoor Air 93, vol 1, pp 535-540.
    • (1993) Indoor Air 93 , vol.1 , pp. 535-540
    • Scherer, G.1    Ruppert, T.2    Draube, H.3    Tricker, A.R.4    Adlkofer, F.5
  • 29
    • 0025361111 scopus 로고
    • Titrating exposure to tobacco smoke using cotinine a minefield of misunderstandings
    • Idle JR: Titrating exposure to tobacco smoke using cotinine a minefield of misunderstandings. J Clin Epidemiol 1990;43:313-317.
    • (1990) J Clin Epidemiol , vol.43 , pp. 313-317
    • Idle, J.R.1
  • 32
    • 0009002478 scopus 로고
    • Providing Constant Ventilation in Variable Air Volume Systems
    • Cohen T: Providing Constant Ventilation in Variable Air Volume Systems. ASHRAE J 1994;36:38-40.
    • (1994) ASHRAE J , vol.36 , pp. 38-40
    • Cohen, T.1
  • 34
    • 0023118731 scopus 로고
    • Environmental tobacco smoke and indoor air quality in modern office work environments
    • Sterling TD, Collett CW, Sterling EM: Environmental tobacco smoke and indoor air quality in modern office work environments. J Occup Med 1987;29:57-62.
    • (1987) J Occup Med , vol.29 , pp. 57-62
    • Sterling, T.D.1    Collett, C.W.2    Sterling, E.M.3
  • 35
    • 0023759093 scopus 로고
    • 2 in non-smoking areas of offices ventilated by air recirculated from smoking designated areas
    • 2 in non-smoking areas of offices ventilated by air recirculated from smoking designated areas. J Am Ind Hyg Assoc 1988;49:423-426.
    • (1988) J Am ind Hyg Assoc , vol.49 , pp. 423-426
    • Sterling, T.D.1    Mueller, B.2
  • 36
    • 0025277692 scopus 로고
    • A personal monitoring study to assess workplace exposure to environmental tobacco smoke
    • Coultas DB, Samet JM, McCarthy JF, Spengler JD: A personal monitoring study to assess workplace exposure to environmental tobacco smoke. Am J Public Health 1990;80:988-990.
    • (1990) Am J Public Health , vol.80 , pp. 988-990
    • Coultas, D.B.1    Samet, J.M.2    McCarthy, J.F.3    Spengler, J.D.4
  • 38
    • 0027716332 scopus 로고
    • An enforceable indoor air quality standard for environmental tobacco smoke in the workplace
    • Repace JL, Lowrey AH: An enforceable indoor air quality standard for environmental tobacco smoke in the workplace. Risk Analysis 1993; 13:463-475.
    • (1993) Risk Analysis , vol.13 , pp. 463-475
    • Repace, J.L.1    Lowrey, A.H.2
  • 39
    • 0000140409 scopus 로고
    • Notice of Proposed Rule-making for Indoor Air Quality (29 CFR Parts 1910, 1915, 1926, 1928)
    • US Occupational Safety and Health Administration (OSHA): Notice of Proposed Rule-making for Indoor Air Quality (29 CFR Parts 1910, 1915, 1926, 1928). Federal Register 1994;59: 15968-16039.
    • (1994) Federal Register , vol.59 , pp. 15968-16039


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.