메뉴 건너뛰기




Volumn 37, Issue 34, 1998, Pages 8120-8128

Ultrasonic hydrophone based on short in-fiber Bragg gratings

Author keywords

[No Author keywords available]

Indexed keywords


EID: 0000434710     PISSN: 1559128X     EISSN: 21553165     Source Type: Journal    
DOI: 10.1364/AO.37.008120     Document Type: Article
Times cited : (81)

References (26)
  • 1
    • 0021816513 scopus 로고
    • Optimization of exposure conditions for medical ultrasound
    • W. L. Nyborg, “Optimization of exposure conditions for medical ultrasound, ” Ultrasound Med. Biol. 11, 245-260 (1985).
    • (1985) Ultrasound Med. Biol , vol.11 , pp. 245-260
    • Nyborg, W.L.1
  • 2
    • 0003748537 scopus 로고
    • Biological effects of ultrasound: Mechanisms and clinical implications
    • National Council on Radiation Protection and Measurements, Bethesda, Md
    • National Council on Radiation Protection and Measurements, “Biological effects of ultrasound: mechanisms and clinical implications, ” NCRP Rep. No. 74 (National Council on Radiation Protection and Measurements, Bethesda, Md., 1983).
    • (1983) NCRP Rep , vol.74
  • 3
    • 0028329267 scopus 로고
    • Current status of research on biophysical effects of ultrasound, Ultrasound Med
    • B. B. Barnett, G. R. ter Haar, M. C. Ziskin, W. L. Nyborg, K. Maeda, and J. Bang, “Current status of research on biophysical effects of ultrasound, ” Ultrasound Med. Biol. 20, 205-218 (1994).
    • (1994) Biol. , vol.20 , pp. 205-218
    • Barnett, B.B.1    Ter Haar, G.R.2    Ziskin, M.C.3    Nyborg, W.L.4    Maeda, K.5    Bang, J.6
  • 5
    • 0028271383 scopus 로고
    • Optimum acoustic frequency for focused ultrasound surgery, Ultrasound Med
    • C. R. Hill, “Optimum acoustic frequency for focused ultrasound surgery, ” Ultrasound Med. Biol. 20, 271-277 (1994).
    • (1994) Biol. , vol.20 , pp. 271-277
    • Hill, C.R.1
  • 9
    • 0028496014 scopus 로고
    • An ultrasonic fiber-optic hydrophone incorporating a push-pull Sagnac interferometer
    • S. Knudsen and K. Blotekjaer, “An ultrasonic fiber-optic hydrophone incorporating a push-pull Sagnac interferometer, ” J. Lightwave Technol. 12, 1696-1700 (1994).
    • (1994) J. Lightwave Technol. , vol.12 , pp. 1696-1700
    • Knudsen, S.1    Blotekjaer, K.2
  • 10
    • 0010617727 scopus 로고
    • The characterisation of high frequency ultrasonic fields using polarimetric optical fiber sensor
    • H. L. W. Chan, K. S. Chiang, D. C. Price, and J. L. Gardener, “The characterisation of high frequency ultrasonic fields using polarimetric optical fiber sensor, ” J. Appl. Phys. 66, 1565-1570 (1989).
    • (1989) J. Appl. Phys. , vol.66 , pp. 1565-1570
    • Chan, H.L.W.1    Chiang, K.S.2    Price, D.C.3    Gardener, J.L.4
  • 11
    • 0024398041 scopus 로고
    • Use of a fiber-optic hydrophone in measuring acoustic parameters of high power hyperthermia transducers
    • H. L. W. Chan, K. S. Chiang, D. C. Price, J. L. Gardener, and J. Brinch, “Use of a fiber-optic hydrophone in measuring acoustic parameters of high power hyperthermia transducers, ” Phys. Med. Biol. 34, 1609-1622 (1989).
    • (1989) Phys. Med. Biol. , vol.34 , pp. 1609-1622
    • Chan, H.L.W.1    Chiang, K.S.2    Price, D.C.3    Gardener, J.L.4    Brinch, J.5
  • 12
    • 0025468479 scopus 로고
    • Detection of high frequency ultrasound with polarisation maintaining fiber
    • K. S. Chiang, H. L. W. Chan, and J. L. Gardener, “Detection of high frequency ultrasound with polarisation maintaining fiber, ” J. Lightwave Technol. 8, 1221-1227 (1990).
    • (1990) J. Lightwave Technol. , vol.8 , pp. 1221-1227
    • Chiang, K.S.1    Chan, H.L.W.2    Gardener, J.L.3
  • 13
    • 0029225822 scopus 로고
    • Optical fiber sensor for the detection of laser-generated ultrasound in arterial tissues
    • A. M. Verga Scheggi, F. Baldini, P. R. Coulet, and O. S. Wolfbeis, eds. Proc. SPIE 2331
    • P. C. Beard and T. N. Mills, “Optical fiber sensor for the detection of laser-generated ultrasound in arterial tissues, ” in Medical Sensors II and Fiber Optic Sensors, A. M. Verga Scheggi, F. Baldini, P. R. Coulet, and O. S. Wolfbeis, eds. Proc. SPIE 2331, 112-122 (1994).
    • (1994) Medical Sensors II and Fiber Optic Sensors , pp. 112-122
    • Beard, P.C.1    Mills, T.N.2
  • 15
    • 0031118065 scopus 로고    scopus 로고
    • Miniature optical fibre ultrasonic hydrophone using a Fabry-Perot polymer film interferometer
    • P. C. Beard and T. N. Mills, “Miniature optical fibre ultrasonic hydrophone using a Fabry-Perot polymer film interferometer, ” Electron. Lett. 33, 801-803 (1997).
    • (1997) Electron. Lett. , vol.33 , pp. 801-803
    • Beard, P.C.1    Mills, T.N.2
  • 17
    • 4143054718 scopus 로고    scopus 로고
    • In-fibre Bragg grating sensors
    • Y.-J. Rao, “In-fibre Bragg grating sensors, ” Meas. Sci. Technol. 8, 355-375 (1997).
    • (1997) Meas. Sci. Technol. , vol.8 , pp. 355-375
    • Rao, Y.-J.1
  • 18
    • 0020478390 scopus 로고
    • Pseudo-heterodyne detection scheme for optical interferometer
    • D. A. Jackson, A. D. Kersey, M. Corke, and J. D. C. Jones, “Pseudo-heterodyne detection scheme for optical interferometer, ” Electron. Lett. 18, 1081-1083 (1982).
    • (1982) Electron. Lett. , vol.18 , pp. 1081-1083
    • Jackson, D.A.1    Kersey, A.D.2    Corke, M.3    Jones, J.D.C.4
  • 19
    • 0027144097 scopus 로고
    • Fiber-optic grating strain sensor with drift-compensated high-resolution interferometric wavelength-shift detection
    • A. D. Kersey, T. A. Berkoff, and W. W. Morey, “Fiber-optic grating strain sensor with drift-compensated high-resolution interferometric wavelength-shift detection, ” Opt. Lett. 18, 72-74 (1993).
    • (1993) Opt. Lett. , vol.18 , pp. 72-74
    • Kersey, A.D.1    Berkoff, T.A.2    Morey, W.W.3
  • 20
    • 0018590048 scopus 로고
    • Analysis of focusing action of spherically curved transducers
    • G. Kossoff, “Analysis of focusing action of spherically curved transducers, ” Ultrasound Med. Biol. 5, 359-365 (1979).
    • (1979) Ultrasound Med. Biol , vol.5 , pp. 359-365
    • Kossoff, G.1
  • 25
    • 0031146562 scopus 로고    scopus 로고
    • In-fibre Bragg-grating temperature sensor system for medical applications
    • Y. Rao, D. J. Webb, D. A. Jackson, L. Zhang, and I. Bennion, “In-fibre Bragg-grating temperature sensor system for medical applications, ” J. Lightwave Technol. 15, 779-785 (1997).
    • (1997) J. Lightwave Technol. , vol.15 , pp. 779-785
    • Rao, Y.1    Webb, D.J.2    Jackson, D.A.3    Zhang, L.4    Bennion, I.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.