메뉴 건너뛰기




Volumn 34, Issue 9, 1996, Pages 394-398

Behavior of Weak Acid Anions in Response to Changes in Mobile Phase pH in Indirect Photometric Chromatography

Author keywords

[No Author keywords available]

Indexed keywords


EID: 0000225063     PISSN: 00219665     EISSN: None     Source Type: Journal    
DOI: 10.1093/chromsci/34.9.394     Document Type: Article
Times cited : (4)

References (12)
  • 1
    • 0020100163 scopus 로고
    • Indirect photometric chromatography
    • H. Small and T.E. Miller, Jr. Indirect photometric chromatography. Anal. Chem. 54: 462-69 (1982).
    • (1982) Anal. Chem. , vol.54 , pp. 462-469
    • Small, H.1    Miller Jr., T.E.2
  • 2
    • 0022014285 scopus 로고
    • Application of indirect photometric chromatography to pharmaceutical analysis
    • D.R. Jenke and N. Raghavan. Application of indirect photometric chromatography to pharmaceutical analysis. J. Chromatogr. Sci. 23: 75-80 (1985).
    • (1985) J. Chromatogr. Sci. , vol.23 , pp. 75-80
    • Jenke, D.R.1    Raghavan, N.2
  • 3
    • 0022134247 scopus 로고
    • Elimination of matrix related interferences in indirect photometric chromatography
    • D. Brown, R. Payton, and D. Jenke. Elimination of matrix related interferences in indirect photometric chromatography. Anal. Chem. 57: 2264-67 (1985).
    • (1985) Anal. Chem. , vol.57 , pp. 2264-2267
    • Brown, D.1    Payton, R.2    Jenke, D.3
  • 4
    • 0021529264 scopus 로고
    • Standardization of transparent analyte response in indirect photometric chromatography
    • D.R. Jenke. Standardization of transparent analyte response in indirect photometric chromatography. Anal. Chem. 56: 2468-70 (1984).
    • (1984) Anal. Chem. , vol.56 , pp. 2468-2470
    • Jenke, D.R.1
  • 5
    • 2542616184 scopus 로고
    • Quantitative ion chromatography with an ultraviolet absorbance detector without standards
    • S.A. Wilson and E.S. Yeung. Quantitative ion chromatography with an ultraviolet absorbance detector without standards. Anal. Chim. Acta. 157: 53-63 (1984).
    • (1984) Anal. Chim. Acta. , vol.157 , pp. 53-63
    • Wilson, S.A.1    Yeung, E.S.2
  • 6
    • 0020087358 scopus 로고
    • Multiple eluent and pH effects on ion chromatography of phosphate and arsenate
    • T.B. Hoover. Multiple eluent and pH effects on ion chromatography of phosphate and arsenate. Sep. Sci. Technol. 17: 295-305 (1982).
    • (1982) Sep. Sci. Technol. , vol.17 , pp. 295-305
    • Hoover, T.B.1
  • 7
    • 0021120686 scopus 로고
    • Models for prediction of retention in non-suppressed ion chromatography
    • D.R. Jenke and G.K. Pagenkopf. Models for prediction of retention in non-suppressed ion chromatography. Anal. Chem. 56: 88-92 (1984).
    • (1984) Anal. Chem. , vol.56 , pp. 88-92
    • Jenke, D.R.1    Pagenkopf, G.K.2
  • 8
    • 0025293109 scopus 로고
    • Influence of dissociation equilibria on the elution behavior of the sample anion in anion chromatography
    • N. Hirayama and T. Kuwamoto. Influence of dissociation equilibria on the elution behavior of the sample anion in anion chromatography. J. Chromatogr. 508: 51-60 (1990).
    • (1990) J. Chromatogr. , vol.508 , pp. 51-60
    • Hirayama, N.1    Kuwamoto, T.2
  • 9
    • 0000539063 scopus 로고
    • Prediction of retention characteristics of multiprotic anions in ion chromatography
    • D.R. Jenke. Prediction of retention characteristics of multiprotic anions in ion chromatography. Anal. Chem. 66: 4466-70 (1994).
    • (1994) Anal. Chem. , vol.66 , pp. 4466-4470
    • Jenke, D.R.1
  • 10
    • 0000994383 scopus 로고
    • Prediction of retention for halide and oxoanions in ion chromatography using multiple species eluent
    • P. Hajos, O. Horvath, and V. Denke. Prediction of retention for halide and oxoanions in ion chromatography using multiple species eluent. Anal. Chem. 67: 434-41 (1995).
    • (1995) Anal. Chem. , vol.67 , pp. 434-441
    • Hajos, P.1    Horvath, O.2    Denke, V.3
  • 12
    • 2542512564 scopus 로고
    • Use of multiple detectors and gradient elution in non-suppressed ion chromatography
    • D.R. Jenke, P.K. Mitchell, and G.K. Pagenkopf. Use of multiple detectors and gradient elution in non-suppressed ion chromatography. Anal. Chim. Acta. 155: 279-85 (1983).
    • (1983) Anal. Chim. Acta. , vol.155 , pp. 279-285
    • Jenke, D.R.1    Mitchell, P.K.2    Pagenkopf, G.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.