메뉴 건너뛰기




Volumn 3032, Issue , 1997, Pages 388-394

6-MVp x-ray imaging with a transparent scintillator x-ray detector

Author keywords

Portal imager; Radiation therapy; Transparent scintillator; X ray detector

Indexed keywords

ANIMAL CELL CULTURE; CHARGE COUPLED DEVICES; DETECTORS; DIGITAL CAMERAS; DIGITAL IMAGE STORAGE; EUROPIUM; GADOLINIUM; IMAGE QUALITY; IMAGE SENSORS; IMAGING SYSTEMS; LIGHT EMISSION; LIQUEFIED GASES; LIQUID NITROGEN; LUMINESCENCE; OPTOELECTRONIC DEVICES; PHOTONS; RADIOTHERAPY; SCINTILLATION; SCINTILLATION COUNTERS; X RAY APPARATUS; X RAYS;

EID: 0000092799     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.274006     Document Type: Conference Paper
Times cited : (2)

References (8)
  • 3
    • 0022505036 scopus 로고
    • Use of digital fluoroscopy as an on-line verification device in radiation therapy
    • J. Leong: Use of digital fluoroscopy as an on-line verification device in radiation therapy, Phys. Med. Biol. Vol 31, pp. 985-992, 1986
    • (1986) Phys. Med. Biol , vol.31 , pp. 985-992
    • Leong, J.1
  • 7
    • 0029829755 scopus 로고    scopus 로고
    • This LN2 cooled CCD has a considerably lower dark current (1 electron per pixel per hour) than the CCD's presently used in commercially available or prototype video based portal imaging systems. See e.g. V.G.M Althof, J.C.J. de Boer, H. Huizerga, J.C. Storm and A.G. Visser: Physical characteristics of a commercial electronic portal imaging device, Med. Phys. 2311, pp. 1845-1855, 1996
    • 2 cooled CCD has a considerably lower dark current (1 electron per pixel per hour) than the CCD's presently used in commercially available or prototype video based portal imaging systems. See e.g. V.G.M Althof, J.C.J. de Boer, H. Huizerga, J.C. Storm and A.G. Visser: Physical characteristics of a commercial electronic portal imaging device, Med. Phys. Vol. 23(11), pp. 1845-1855, 1996.
  • 8
    • 0028025610 scopus 로고    scopus 로고
    • 3(Eu) and CsI(Tl) screens have better MTF values than those of commercially available or prototype portal imaging systems. See e.g. B. Wowk and S. Shalev: Thick phosphor screens for online portal imaging, Med. Phys. 21(8), pp. 1269-1276, 1994.
    • 3(Eu) and CsI(Tl) screens have better MTF values than those of commercially available or prototype portal imaging systems. See e.g. B. Wowk and S. Shalev: Thick phosphor screens for online portal imaging, Med. Phys. Vol 21(8), pp. 1269-1276, 1994.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.